Effect of red blood cell concentration on the blood flow in patient-specific aneurysms

被引:0
|
作者
Pahlavani, H. [1 ]
Ozdemir, I. Bedii [1 ]
机构
[1] Fluids Group, Faculty of Mechanical Engineering, Istanbul Technical University, Istanbul
关键词
Aneurysm; CFD; Euler–Euler method; Multi-phase blood flow; Non-Newtonian blood rheology;
D O I
10.1007/s42600-024-00381-4
中图分类号
学科分类号
摘要
Purpose: Because plasma and red blood cells are the predominant components of human blood, their abundance and deficiency can arise serious consequences related to cerebral aneurysms. The effect of variations in the hematocrit level on the blood flow was studied in two cerebral aneurysms. Method: A three-dimensional computational fluid dynamics study being capable of handling multi-phase nature of blood flow was performed to examine the effect of hematocrit variation in two patient-specific aneurysms. The Euler–Euler method and the Carreau–Yasuda viscosity models were used for the simulations. Blood inflow jet penetration depth, flow patterns in the impingement zone, complexity of flow in the aneurysm sac region and wall shear stress-based parameters are investigated at different hematocrit levels. Results: The results showed that the maximum inflow jet penetration was achieved at the lowest hematocrit level. This was accompanied with strong flow impingements at the narrow corners deep inside the aneurysm sac and undesired complex flow patterns extending from the entrance to the aneurysm dome. Conclusions: The decrease in hematocrit level changed the characteristics of the velocity profile inside the dome from a single- to a double-peak distribution, which increased the likelihood of a daughter aneurysm formation. Furthermore, the time averaged wall shear stress and oscillatory shear index indicators showed that lowering the hematocrit values could change an initially low-risk case into a very high rupture risk situation. © The Author(s), under exclusive licence to The Brazilian Society of Biomedical Engineering 2024.
引用
收藏
相关论文
共 50 条
  • [41] Effect of left ventricular assist device on the hemodynamics of a patient-specific left heart
    Kannojiya, Vikas
    Das, Arup Kumar
    Das, Prasanta Kumar
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2022, 60 (06) : 1705 - 1721
  • [42] Does the DSA reconstruction kernel affect hemodynamic predictions in intracranial aneurysms? An analysis of geometry and blood flow variations
    Berg, P.
    Saalfeld, S.
    Voss, S.
    Redel, T.
    Preim, B.
    Janiga, G.
    Beuing, O.
    JOURNAL OF NEUROINTERVENTIONAL SURGERY, 2018, 10 (03) : 290 - 296
  • [43] Effect of left ventricular assist device on the hemodynamics of a patient-specific left heart
    Vikas Kannojiya
    Arup Kumar Das
    Prasanta Kumar Das
    Medical & Biological Engineering & Computing, 2022, 60 : 1705 - 1721
  • [44] How patient-specific do internal carotid artery inflow rates need to be for computational fluid dynamics of cerebral aneurysms?
    Najafi, Mehdi
    Cancelliere, Nicole M.
    Brina, Olivier
    Bouillot, Pierre
    Vargas, Maria, I
    Delattre, Benedicte Ma
    Pereira, Vitor M.
    Steinman, David A.
    JOURNAL OF NEUROINTERVENTIONAL SURGERY, 2021, 13 (05) : 459 - 464
  • [45] Patient specific 3-d modeling of blood flow in a multi-stenosed left coronary artery
    Kamangar, Sarfaraz
    Badruddin, Irfan Anjum
    Ahamad, N. Ameer
    Soudagar, Manzoor Elahi M.
    Govindaraju, Kalimuthu
    Nik-Ghazali, N.
    Ahmed, N. J. Salman
    Khan, T. M. Yunus
    BIO-MEDICAL MATERIALS AND ENGINEERING, 2017, 28 (03) : 257 - 266
  • [46] Are Blood Blister-Like Aneurysms a Specific Type of Dissection? A Comparative Study of Blood Blister-Like Aneurysms and Ruptured Mizutani Type 4 Vertebral Artery Dissections
    Sim, Sook Young
    Chung, Joonho
    Shin, Yong Sam
    JOURNAL OF KOREAN NEUROSURGICAL SOCIETY, 2014, 56 (05) : 395 - 399
  • [47] Size-Dependent Distribution of Patient-Specific Hemodynamic Factors in Unruptured Cerebral Aneurysms Using Computational Fluid Dynamics
    Lee, Ui Yun
    Chung, Gyung Ho
    Jung, Jinmu
    Kwak, Hyo Sung
    DIAGNOSTICS, 2020, 10 (02)
  • [48] Impact of aneurysm sac size on the effectiveness of endovascular coiling in patient-specific middle cerebral artery aneurysms: a computational study
    Yao, Zhichao
    Wen, Hao
    SCIENTIFIC REPORTS, 2025, 15 (01):
  • [49] HEART RATE EFFECT ON BLOOD FLOW HEMODYNAMICS IN A PATIENT WITH A THORACIC AORTIC ANEURYSM: NUMERICAL STUDY
    Faraji, A.
    Sahebi, M.
    Dezfouli, S. S.
    JOURNAL OF APPLIED MECHANICS AND TECHNICAL PHYSICS, 2024, 65 (03) : 465 - 475
  • [50] Computational investigation of blood flow in fusiform models of aortic aneurysms: a steady state analysis
    Vinoth, R.
    Kumar, D.
    Adhikari, Raviraj
    Devaprasad, Dedeepiya
    Kaliyamoorthy, Dhamodharan
    INTERNATIONAL JOURNAL OF BIOMEDICAL ENGINEERING AND TECHNOLOGY, 2015, 19 (01) : 70 - 91