Horizontal functionally graded material coating of cementless hip prosthesis

被引:0
|
作者
Fouda, N. [1 ]
机构
[1] Mansoura University, Faculty of Engineering, Mansoura, Egypt
来源
关键词
Bone - Optimal systems - Finite element method - Beams and girders - Metal coatings - Stiffness - Titanium - Metal implants - Hip prostheses - Shear stress;
D O I
暂无
中图分类号
学科分类号
摘要
Geometry and material property optimization represent the possible methods of using prosthesis stiffness for alignment with bone stiffness and increasing total hip replacement lifespan. Previous researchers have tried to substitute conventional materials for new materials such as composites in femoral prosthesis. The concept of functionally graded materials (FGMs) was taken from biological structures. Previous study was carried out by Hedia and Fouda [1] to design the coating of a cementless hip prosthesis as a vertical FGM. In this study a finite element analysis and optimization method have been carried out in order to design the coating of cementless hip stem using the horizontal FGM to diminish stress shielding at the medial proximal region of the femur, as well as reducing the interface shear stress between the coating and bone that affects the long term stability of the hip implant. The optimal design compared with HAP coating and with homogenous uncoated titanium stem. The optimal design showed that using a coating material consists of collagen at the inner layer adjacent to stem graded to HAP at the outer layer adjacent to bone, increase the maximum von Mises stress at the medial proximal region of the femur by 60% and 15% compared to titanium stem and titanium coated with HAP, respectively. The maximum lateral shear stress is reduced by 18% and 6%. However, the maximum medial shear stress is reduced by 35% and 8% compared to titanium stem and titanium coated with HAP, respectively.
引用
收藏
页码:58 / 64
相关论文
共 50 条
  • [41] Thermo-elasto-plastic stresses of functionally graded material plate with a substrate and a coating
    Shabana, YM
    Noda, N
    JOURNAL OF THERMAL STRESSES, 2002, 25 (12) : 1133 - 1146
  • [42] Primary cementless hip arthroplasty with a titanium plasma sprayed prosthesis
    Hozack, WJ
    Rothmann, RH
    Eng, K
    Mesa, J
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1996, (333) : 217 - 225
  • [43] NUMERICAL OPTIMIZATION OF THE DESIGN OF A COATED, CEMENTLESS HIP-PROSTHESIS
    EVANS, SL
    GREGSON, PJ
    JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE, 1994, 5 (08) : 507 - 510
  • [44] Use of Functionally Graded Material to Decrease Maximum Temperature of a Coating-Substrate System
    Yevtushenko, Aleksander
    Topczewska, Katarzyna
    Zamojski, Przemyslaw
    MATERIALS, 2023, 16 (06)
  • [45] Total hip arthroplasty with the cementless spiron femoral neck prosthesis
    Lugeder, A.
    Haering, E.
    Mueller, A.
    Droste, P.
    Zeichen, J.
    OPERATIVE ORTHOPADIE UND TRAUMATOLOGIE, 2013, 25 (04): : 388 - 397
  • [46] Retrieval analysis of a cementless modular total hip arthroplasty prosthesis
    Paliwal, Manish
    Allan, D. Gordon
    Filip, Peter
    PROCEEDINGS OF THE 7TH IEEE INTERNATIONAL SYMPOSIUM ON BIOINFORMATICS AND BIOENGINEERING, VOLS I AND II, 2007, : 553 - +
  • [47] CLINICAL AND RADIOLOGICAL STUDY OF CERAMIC CEMENTLESS HIP-PROSTHESIS
    NAGAYA, I
    ASAI, T
    MIYAKE, N
    ETOH, Y
    ZEITSCHRIFT FUR RHEUMATOLOGIE, 1988, 47 (04): : 317 - 317
  • [48] PRIMARY RESULTS OF THE LORD CEMENTLESS TOTAL HIP-PROSTHESIS
    STROMSOE, K
    OSLEBY, P
    ALHO, A
    ACTA ORTHOPAEDICA SCANDINAVICA, 1986, 57 (03): : 273 - 273
  • [49] Stem fracture of the cementless spongy metal Lubeck hip prosthesis
    Kishida, Y
    Sugano, N
    Ohzono, K
    Sakai, T
    Nishii, T
    Yoshikawa, H
    JOURNAL OF ARTHROPLASTY, 2002, 17 (08): : 1021 - 1027
  • [50] Patient specific parametric geometric modelling of cementless hip prosthesis
    Kumar, G. Saravana
    Gupta, M.
    INNOVATIVE DEVELOPMENTS ON VIRTUAL AND PHYSICAL PROTOTYPING, 2012, : 187 - 193