Innovative adaptive virtual impedance for resonance frequency mitigation in grid-connected converters

被引:0
作者
Saïd-Romdhane, Marwa Ben [1 ,2 ]
Haddad, Mohamed [1 ]
Slama-Belkhodja, Ilhem [1 ]
机构
[1] Université de Tunis El Manar, Ecole Nationale d'Ingénieurs de Tunis, LR11ES15 Laboratoire de Systèmes Electriques, Tunis
[2] Université de Gabès, Institut Supérieur des Sciences Appliquées et de Technologie de Gabès, Gabès
关键词
Emulators; Grid impedance; LCL filter; LCL filter resonance; Microgrid; Multiple parallel grid-connected inverters; PV system; Residual; Stability; Virtual impedance;
D O I
10.1016/j.epsr.2024.111207
中图分类号
学科分类号
摘要
Microgrid architectures are typically composed of multiple parallel grid-connected inverters, interconnected via LCL filters to comply with grid code requirements while offering low cost and superior dynamic performance compared to L filters. However, the use of LCL filters in microgrids introduces two types of resonance: extrinsic resonance related to each LCL filter and intrinsic resonance resulting from the coupling effects of multiple parallel LCL filters. These resonances can lead to small oscillations, degrading power quality, or large oscillations, compromising microgrid reliability and stability, especially with variations and poor design of LCL filter parameters. Thus, early detection and correction of these oscillations are essential for resilient microgrid operation. This paper proposes a residual-based adaptive virtual impedance technique to effectively detect and mitigate unwanted resonance frequencies. Unlike previous approaches that primarily focus on static impedance adjustments or non-adaptive methods with slow detection of the undesired resonance frequencies, the proposed method diverges by emphasizing the dual functionality of the virtual impedance. It operates in two steps: first, a residual algorithm swiftly identifies undesired oscillations, producing higher values during instability and low values under normal conditions. Second, an adaptive virtual impedance is introduced to restore stability, with its components continuously computed until the residual value falls below the threshold for normal operation. Unlike previous approaches that often focus solely on harmonic sharing or stability without addressing the rapid detection of oscillations, the proposed technique integrates both detection and mitigation, providing a robust solution for enhancing microgrid stability and reliability in the presence of resonances. A comprehensive case study, including simulations, real-time simulations, and experimental tests, is conducted to validate the technique's effectiveness and superior performance. © 2024
引用
收藏
相关论文
共 50 条
  • [21] Comprehensive Analysis of Virtual Impedance-Based Active Damping for LCL Resonance in Grid-Connected Inverters
    Liu, Teng
    Liu, Zeng
    Liu, Jinjun
    Tu, Yiming
    Liu, Zipeng
    2018 INTERNATIONAL POWER ELECTRONICS CONFERENCE (IPEC-NIIGATA 2018 -ECCE ASIA), 2018, : 2681 - 2687
  • [22] Adaptive Supplementary Control of VSG Based on Virtual Impedance for Current Limiting in Grid-Connected and Islanded Microgrids
    Jafariazad, Amir Hossein
    Taher, Seyed Abbas
    Arani, Zahra Dehghani
    Karimi, Mohammad Hossein
    Guerrero, Josep M.
    IEEE TRANSACTIONS ON SMART GRID, 2024, 15 (01) : 89 - 98
  • [23] Resonance Damping Techniques for Grid-Connected Voltage Source Converters with LCL filters - A Review
    Zhang, Chi
    Dragicevic, Tomislav
    Vasquez, Juancho C.
    Guerrero, Josep M.
    2014 IEEE INTERNATIONAL ENERGY CONFERENCE (ENERGYCON 2014), 2014, : 169 - 176
  • [24] A multi-loop controller for LCL-filtered grid-connected converters integrated with a hybrid harmonic compensation and a novel virtual impedance
    Cho, Yonghwan
    Mobarrez, Maziar
    Bhattacharya, Subhashish
    2017 THIRTY SECOND ANNUAL IEEE APPLIED POWER ELECTRONICS CONFERENCE AND EXPOSITION (APEC), 2017, : 2658 - 2663
  • [25] Harmonic compensation Control of Grid-connected Inverter based on Virtual Impedance
    Piao, Zhengguo
    Zhong, Yueping
    2018 21ST INTERNATIONAL CONFERENCE ON ELECTRICAL MACHINES AND SYSTEMS (ICEMS), 2018, : 2364 - 2368
  • [26] Using Virtual Impedance to Analyze the Stability of LCL-Filtered Grid-Connected Inverters
    Wang, Jianguo
    Yan, Jiu Dun
    2015 IEEE INTERNATIONAL CONFERENCE ON INDUSTRIAL TECHNOLOGY (ICIT), 2015, : 1220 - 1225
  • [27] Grid-Current-Feedback Active Damping for LCL Resonance in Grid-Connected Voltage-Source Converters
    Wang, Xiongfei
    Blaabjerg, Frede
    Loh, Poh Chiang
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2016, 31 (01) : 213 - 223
  • [28] Online grid impedance estimation for grid-connected inverters using APT-BMFO
    Palanisamy, N.
    Michael, Prawin Angel
    SUSTAINABLE ENERGY TECHNOLOGIES AND ASSESSMENTS, 2023, 56
  • [29] Phase-reshaping strategy for enhancing grid-connected inverter robustness to grid impedance
    Zhou Lin
    Zheng Chen
    Liu Yajuan
    Li Bin
    Liu Jinhong
    Xie Bao
    IET POWER ELECTRONICS, 2018, 11 (08) : 1434 - 1443
  • [30] Adaptive controller based on grid impedance estimation for stable operation of grid-connected inverters under weak grid conditions
    Temiz, Hakan
    Keysan, Ozan
    Demirok, Erhan
    IET POWER ELECTRONICS, 2020, 13 (13) : 2692 - 2705