Omnidirectional Wireless Power Transfer for Millimetric Magnetoelectric Biomedical Implants

被引:0
|
作者
Wang, Wei [1 ]
Yu, Zhanghao [1 ]
Zou, Yiwei [1 ]
Woods, Joshua E. [1 ]
Chari, Prahalad [1 ]
Su, Yumin [1 ]
Robinson, Jacob T. [1 ]
Yang, Kaiyuan [1 ]
机构
[1] Rice Univ, Dept Elect & Comp Engn, Houston, TX 77005 USA
基金
美国国家科学基金会; 美国国家卫生研究院;
关键词
Coils; Implants; Magnetic fields; Couplings; Magnetoelectric effects; Sensors; Wireless power transfer; Ultrasonic imaging; Sensitivity; Inductive coupling; Bioelectronics; implantable device; magnetoelectric (ME); omnidirectional; wireless power transfer (WPT); STIMULATION; SYSTEMS; DESIGN;
D O I
10.1109/JSSC.2024.3464533
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Miniature bioelectronic implants promise revolutionary therapies for cardiovascular and neurological disorders. Wireless power transfer (WPT) is a significant method for miniaturization, eliminating the need for bulky batteries in today's devices. Despite successful demonstrations of millimetric battery-free implants in animal models, the robustness and efficiency of WPT are known to degrade significantly under misalignment incurred by body movements, respiration, heart beating, and limited control of implant orientation during surgery. This article presents an omnidirectional WPT platform for millimetric bioelectronic implants, employing the emerging magnetoelectric (ME) WPT modality, and "magnetic field steering" technique based on multiple transmitter (TX) coils. To accurately sense the weak coupling in a miniature implant and adaptively control the multicoil TX array in a closed loop, we develop an active echo (AE) scheme using a tiny coil on the implant. Our prototype comprises a fully integrated 14.2 mm $<^>3$ implantable stimulator embedding a custom low-power system-on-chip (SoC) powered by an ME film, a TX with a custom three-channel AE RX chip, and a multicoil TX array with mutual inductance cancellation. The AE RX achieves $-$ 161 dBm/Hz input-referred noise with 64 dB gain tuning range to reliably sense the AE signal, and offers fast polarity detection for driver control. AE simultaneously enhances the robustness, efficiency, and charging range of ME WPT. Under 90 $<^>{\circ}$ rotation from the ideal position, our omnidirectional WPT system achieves 6.8 $\times$ higher power transfer efficiency (PTE) than a single-coil baseline. The tracking error of AE negligibly degrades the PTE by less than 2% from using ideal control.
引用
收藏
页码:3599 / 3611
页数:13
相关论文
共 50 条
  • [1] Magnetoelectric Wireless Power Transfer System for Biomedical Implants
    Mukherjee, Dibyajyoti
    Mallick, Dhiman
    2021 IEEE INTERNATIONAL MIDWEST SYMPOSIUM ON CIRCUITS AND SYSTEMS (MWSCAS), 2021, : 356 - 359
  • [2] A self-biased magnetoelectric wireless power transfer receiver targeting biomedical implants
    Saha, Orpita
    Andersen, Erik
    Roundy, Shad
    SENSORS AND ACTUATORS A-PHYSICAL, 2023, 360
  • [3] A Low-Frequency Versatile Wireless Power Transfer Technology for Biomedical Implants
    Jiang, Hao
    Zhang, Junmin
    Lan, Di
    Chao, Kelvin K.
    Liou, Shyshenq
    Shahnasser, Hamid
    Fechter, Richard
    Hirose, Shinjiro
    Harrison, Michael
    Roy, Shuvo
    IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS, 2013, 7 (04) : 526 - 535
  • [4] MISALIGNMENT ANALYSIS OF RESONANCE-BASED WIRELESS POWER TRANSFER TO BIOMEDICAL IMPLANTS
    Senjuti, Shawon
    Fricke, Kyle
    Dounavis, Anestis
    Sobot, Robert
    2012 25TH IEEE CANADIAN CONFERENCE ON ELECTRICAL & COMPUTER ENGINEERING (CCECE), 2012,
  • [5] Cylindrical Transmitting Coil for Two-Dimensional Omnidirectional Wireless Power Transfer
    Ha-Van, Nam
    Liu, Yining
    Jayathurathnage, Prasad
    Simovski, Constantin R.
    Tretyakov, Sergei A.
    IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2022, 69 (10) : 10045 - 10054
  • [6] Efficiency Optimization and Power Allocation of Omnidirectional Wireless Power Transfer for Multiple Receivers
    Zhu, Zhenghao
    Yang, Aijun
    Yuan, Huan
    Zhao, Cheng
    Chen, Fuguo
    Wang, Xiaohua
    Rong, Mingzhe
    IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2023, 70 (10) : 9689 - 9699
  • [7] Wireless Power Transfer System Design for Biomedical Implants at 2.45 GHz
    Shaw, Tarakeswar
    Mitra, Debasis
    PROCEEDINGS OF THE 2019 IEEE ASIA-PACIFIC MICROWAVE CONFERENCE (APMC), 2019, : 717 - 719
  • [8] Wireless Power Transfer to Biomedical Implants Using a Class-E Inverter and a Class-DE Rectifier
    van Nunen, Tom P. G.
    Mestrom, Rob M. C.
    Visser, Hubregt J.
    IEEE JOURNAL OF ELECTROMAGNETICS RF AND MICROWAVES IN MEDICINE AND BIOLOGY, 2023, 7 (03): : 202 - 209
  • [9] Magnetoelectric wireless power transfer for biomedical implants: Effects of non-uniform magnetic field, alignment and orientation
    Binh Duc Truong
    Andersen, Erik
    Casados, Curtis
    Roundy, Shad
    SENSORS AND ACTUATORS A-PHYSICAL, 2020, 316
  • [10] Omnidirectional Wireless Power Transfer Based on Constant Coupling Polarity Concept
    Yi, Zixuan
    Li, Chenchen
    Yang, Xue-Xia
    Li, Meiling
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2024, 39 (12) : 16894 - 16903