A controllable reactor for reactive power compensation of electrified railways

被引:0
|
作者
Zhang, Yu [1 ]
Chen, Qiaofu [2 ]
Li, Jianghong [1 ]
Wang, Jian [1 ]
Tan, Juan [1 ]
机构
[1] Technology Center of Zhuzhou CSR Times Electric Co. Ltd., Zhuzhou 412001, China
[2] Huazhong University of Science and Technology, Wuhan 430074, China
关键词
Dynamic loads - Electric power utilization - Thyristors - Electric inverters - Railroads - Winding;
D O I
暂无
中图分类号
学科分类号
摘要
A novel controllable reactor is proposed to regulate reactive power of traction substations automatically according to dynamic loading by paralleled with fixed capacitors. This controllable reactor which has multiple second windings connected with anti-parallel thyristors and voltage-source inverter (VSI) respectively, can obtain reactance varying in a wide range continuously by step-switching the thyristors and controlling VSI current, so that implement reactive power adjustment. Simulating and experimental results validate the advantages of the presented reactor such as fast response speed, high compensating precision and low harmonic output et al.
引用
收藏
页码:166 / 171
相关论文
共 50 条
  • [41] ANALYSIS OF GROUNDING SYSTEM FOR THE POWER DISTRIBUTION SYSTEMS OF ELECTRIFIED RAILWAYS WITH SAFETY CONSIDERATIONS
    Ahrabian, Ghasem
    Shahnia, Farhad
    Hosseini, Seyed Hossein
    PROCEEDINGS OF THE 6TH INTERNATIONAL SCIENTIFIC CONFERENCE ELECTRIC POWER ENGINEERING 2005, 2005, : 7 - 11
  • [42] Overview of Power Controllable Reactor Technology
    Liu, Wenye
    Luo, Longfu
    Dong, Shuda
    Lou, Yunge
    2012 INTERNATIONAL CONFERENCE ON FUTURE ELECTRICAL POWER AND ENERGY SYSTEM, PT A, 2012, 17 : 483 - 491
  • [43] Use of covered conductors for electrified railways
    Loo, R.
    Schutte, T.
    Strom, M.
    eb - Elektrische Bahnen, 2001, 99 (6-7): : 268 - 276
  • [44] Development of flickermeter and application in electrified railways
    He, Jian-Min
    Huang, Zhi-Qing
    Li, Qun-Zhan
    Xinan Jiaotong Daxue Xuebao/Journal of Southwest Jiaotong University, 2004, 39 (02):
  • [45] High voltage static var reactive power compensator using shunt magnetically controllable reactor
    Yu, Meng-Ze
    Chen, Bai-Chao
    Tian, Cui-Hua
    Qiu, Hao
    Gaodianya Jishu/High Voltage Engineering, 2009, 35 (07): : 1770 - 1775
  • [46] Calculation of the reactive load compensation by controllable capacitor banks
    KAYALOV GM
    KOVALEV IN
    1971, (08): : 19 - 25
  • [47] A Compensation System for Cophase High-Speed Electric Railways by Reactive Power Generation of SHC&SAC
    Xie, Bin
    Li, Yong
    Zhang, Zhiwen
    Hu, Sijia
    Zhang, Zhixue
    Luo, Longfu
    Cao, Yijia
    Zhou, Fangyuan
    Luo, Renjun
    Long, Lilan
    IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2018, 65 (04) : 2956 - 2966
  • [48] Collaborative compensation strategy of electrified railways and DFIG-based wind farm for suppressing voltage unbalance
    Xiao, Diwen
    Chen, Minwu
    Chen, Yinyu
    Liang, Zongyou
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2022, 141
  • [49] REACTIVE COMPENSATION FOR ELECTRICAL POWER
    GAVRILOVIC, A
    ELECTRICAL REVIEW, 1973, 193 (07): : 231 - 233
  • [50] Reactive Power Compensation in Motor
    Zhou, Xuesong
    Ma, Youjie
    Gao, Zhiqiang
    Zhang, Shaowei
    2017 IEEE INTERNATIONAL CONFERENCE ON MECHATRONICS AND AUTOMATION (ICMA), 2017, : 295 - 299