Internal damage evolution of C/SiC composites in air at 1650 ° C studied by in-situ synchrotron X-ray imaging

被引:6
作者
Xi, Li [1 ,2 ]
Li, Shaoling [1 ,2 ]
Xue, Kaiyuan [1 ,2 ]
Cui, Xiaochuan [1 ,2 ]
Wang, Bowen [1 ,2 ]
Li, Ying [1 ,2 ]
Fang, Daining [1 ,2 ]
机构
[1] Beijing Inst Technol, Inst Adv Struct Technol, Beijing 100081, Peoples R China
[2] Beijing Inst Technol, Beijing Key Lab Lightweight Multifunct Composite M, Beijing 100081, Peoples R China
基金
中国国家自然科学基金;
关键词
Ceramic-matrix composites (CMCs); High-temperature properties; Synchrotron X-ray micro-CT; Digital volume correlation; Internal damage evolution; DIGITAL VOLUME CORRELATION; TEMPERATURES; TOMOGRAPHY; ACCUMULATION; AEROSPACE; BEHAVIOR; STRESS; FIELD; PIP;
D O I
10.1016/j.compositesb.2024.111878
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Carbon fibre reinforced silicon carbide (C/SiC) ceramic matrix composites have attracted considerable attention due to their exceptional properties and extensive potential applications as high-temperature structural materials. However, due to their complex structure and manufacturing defects, C/SiC composites exhibit intricate mechanical behaviour under thermal-mechanical-oxidative coupling environments. To date, systematic studies on the internal damage evolution and failure mechanisms of C/SiC composites under high-temperature oxidative environments are lacking. In this study, a combination of synchrotron X-ray micro-computed tomography (SR mu CT) and in-situ experiments under thermal-mechanical-oxidative coupling environments at room temperature and 1650 degrees C in air was used to characterize the internal microstructures and damage evolution processes of C/SiC composites at different loading levels. Additionally, the 3D strain fields during in-situ loading were quantitatively analysed using the Digital Volume Correlation (DVC) method. The findings underscore the substantial impact of oxidative damage on the mechanical response of C/SiC composites, particularly concerning tensile properties and fracture modes. At room temperature, severe delamination, fibre bundle pull-out and interfacial debonding occurred internally. Whereas, under high-temperature atmospheric conditions, severe fibre oxidation reactions occurred at the specimen edges, resulting in rapid porosity escalation. Crack initiation from surface defects followed by rapid inward propagation is observed. Moreover, while the strain distribution remains relatively uniform until fracture, a pronounced concentration of strain is evident near the fracture zones at room temperature, with an even greater concentration observed at 1650 degrees C. Notably, the region of concentrated strain within the 3D deformation field corresponds closely to the final fracture location, as revealed by quantitative DVC analysis.
引用
收藏
页数:15
相关论文
共 54 条
[11]   Review on mechanics of ultra-high-temperature materials [J].
Fang, Daining ;
Li, Weiguo ;
Cheng, Tianbao ;
Qu, Zhaoliang ;
Chen, Yanfei ;
Wang, Ruzhuan ;
Ai, Shigang .
ACTA MECHANICA SINICA, 2021, 37 (09) :1347-1370
[12]   Full-field characterisation of oxide-oxide ceramic-matrix composites using X-ray computed micro-tomography and digital volume correlation under load at high temperatures [J].
Forna-Kreutzer, J. Paul ;
Ell, Jon ;
Barnard, Harold ;
Pirzada, Talha J. ;
Ritchie, Robert O. ;
Liu, Dong .
MATERIALS & DESIGN, 2021, 208
[13]   Impact of residual stress on thermal damage accumulation, and Young's modulus of fiber-reinforced ultra-high temperature ceramics [J].
Galizia, P. ;
Zoli, L. ;
Sciti, D. .
MATERIALS & DESIGN, 2018, 160 :803-809
[14]   Identification of microstructures and damages in silicon carbide ceramic matrix composites by deep learning [J].
Gao, Xiangyun ;
Lei, Bao ;
Zhang, Yi ;
Zhang, Daxu ;
Wei, Chong ;
Cheng, Laifei ;
Zhang, Litong ;
Li, Xuqin ;
Ding, Hao .
MATERIALS CHARACTERIZATION, 2023, 196
[15]   Mode I and Mode II interfacial fracture energy of SiC/BN/SiC CMCs [J].
Gavalda-Diaz, Oriol ;
Manno, Riccardo ;
Melro, Antonio ;
Allegri, Giuliano ;
Hallett, Stephen R. ;
Vandeperre, Luc ;
Saiz, Eduardo ;
Giuliani, Finn .
ACTA MATERIALIA, 2021, 215
[16]   Characterization of the oxidation of C/C/SiC composites by Xray micro-tomography [J].
Goulmy, J. P. ;
Caty, O. ;
Rebillat, F. .
JOURNAL OF THE EUROPEAN CERAMIC SOCIETY, 2020, 40 (15) :5120-5131
[17]   Tensile damage evolution and mechanical behaviour of SiCf/SiC mini-composites through 4D in-situ micro-CT and data-driven modelling [J].
Guo, Weiyu ;
Zhang, Daxu ;
Zhang, Yi ;
Du, Yonglong ;
Chen, Chao .
COMPOSITES PART B-ENGINEERING, 2024, 279
[18]   Deformation mechanisms and mechanical performances of architected mechanical metamaterials with gyroid topologies: Synchrotron X-ray radiation in-situ compression experiments and 3D image based finite element analysis [J].
Hu, Wenxia ;
Cao, Xiaofei ;
Zhang, Xiaoqiang ;
Huang, Zhixin ;
Chen, Zihao ;
Wu, Wenwang ;
Xi, Li ;
Li, Ying ;
Fang, Daining .
EXTREME MECHANICS LETTERS, 2021, 44
[19]   In-situ formed silicon oxycarbide nanowires into porous SiC(rGO) PDCs enable balanced enhancement of robustness and thermal management [J].
Huang, Wenyan ;
Liang, Jiahao ;
Chen, Kaiqi ;
Yu, Ying ;
Zhu, Yeqi ;
Li, Junhui ;
Pan, Cheng ;
Guo, Yipeng ;
Lan, Siqi ;
Yao, Rongqian .
COMPOSITES PART B-ENGINEERING, 2024, 287
[20]   In-situ micro-CT damage analysis of carbon and carbon/glass hybrid laminates under tensile loading by image reconstruction and DVC technology [J].
Jiang, Lanxin ;
Xiong, Hongzi ;
Zeng, Tao ;
Wang, Jie ;
Xiao, Shoune ;
Yang, Long .
COMPOSITES PART A-APPLIED SCIENCE AND MANUFACTURING, 2024, 176