Evaluation of wind-induced fragility and cumulative fatigue damage on seismically isolated high-rise building

被引:0
|
作者
Tan, Jiajun [1 ,2 ]
Tan, Ping [1 ,2 ]
Wu, Jiurong [1 ,3 ]
Feng, Demin [4 ]
机构
[1] Guangzhou Univ, Sch Civil Engn, Guangzhou 510006, Peoples R China
[2] Guangzhou Univ, Key Lab Earthquake Resistance Earthquake Mitigat &, Minist Educ, Guangzhou 510006, Peoples R China
[3] Guangzhou Univ, Res Ctr Wind Engn & Engn Vibrat, Guangzhou 510006, Peoples R China
[4] China Elect Engn Design Inst Co Ltd, Beijing 100000, Peoples R China
基金
中国国家自然科学基金;
关键词
Seismic isolation; High-rise building; Wind vibration comfort; Wind-resistance stability; Wind-induced fragility; Cumulative fatigue damage; BASE-ISOLATED BUILDINGS; DYNAMICS CHARACTERISTICS; HISTORICAL DEVELOPMENT; ENERGY; TALL; TIME;
D O I
10.1016/j.jweia.2024.105915
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Seismically isolated buildings (SIBs) are built higher and higher for which wind-induced effect is of worldwide concern. To comprehensively study this effect, this paper proposes a theoretical framework of wind-induced fragility evaluation for SIBs. A Chinese seismically isolated high-rise engineering building is systematically evaluated as a case study. The probability wind load demand model for SIBs is developed. The wind-induced performance evaluation indices set according to different national codes are assessed and compared from a probabilistic perspective. A parametric analysis is conducted to explore a reasonable range of values for wind load partial factor. The cumulative fatigue damage at seismic isolation interface (SII) under extreme wind loads is investigated. Results show that SIB can generally meet performance requirements for lateral stiffness. The performance evaluation indices under 1-year return period wind load are more demanding than those under 10-year return period wind load. The value of wind load partial factor is recommended to be within the range of 1.4-1.6 for sufficient wind-resistance stability without compromising seismic reduction performance. The LRB used in SII not only provides wind-resistance stability, but also perform well in resisting wind-induced fatigue damage. Nevertheless, periodic inspections are necessary to assess wind-induced residual deformation at SII.
引用
收藏
页数:14
相关论文
共 50 条
  • [1] Evaluation of wind-induced effect on seismically isolated super high-rise building based on integrated seismic isolation design method: A case study
    Tan, Jiajun
    Tan, Ping
    Wu, Jiurong
    Feng, Demin
    JOURNAL OF BUILDING ENGINEERING, 2023, 76
  • [2] WIND-INDUCED VIBRATION AND DAMAGE DETECTION FOR HIGH-RISE BUILDING
    Zhao, Xin
    Lin, Zhenshan
    PROCEEDINGS OF THE TWELFTH INTERNATIONAL SYMPOSIUM ON STRUCTURAL ENGINEERING, VOLS I AND II, 2012, : 723 - 730
  • [3] Research on wind-induced torsional control with annular damper for high-rise building
    Liu Feipeng
    Liu Ruyi
    Bi Haifeng
    Xin Mingming
    Xu Jiayun
    2016 INTERNATIONAL CONFERENCE ON SMART CITY AND SYSTEMS ENGINEERING (ICSCSE), 2016, : 439 - 444
  • [4] Field measurement of wind-induced stress on glass facade of a coastal high-rise building
    Li ZhengNong
    Luo DieFeng
    Shi WenHai
    Li ZhiQi
    Liang XiaoHan
    SCIENCE CHINA-TECHNOLOGICAL SCIENCES, 2011, 54 (10) : 2587 - 2596
  • [5] Full-scale measurement of wind-induced internal pressures in a high-rise building
    Kato, N
    Niihori, Y
    Kurita, T
    Ohkuma, T
    JOURNAL OF WIND ENGINEERING AND INDUSTRIAL AERODYNAMICS, 1997, 71 : 619 - 630
  • [6] Field Measurement on Translational and Torsional Wind-Induced Response of a High-Rise Building during Typhoon Khanun
    Hu, Jiaxing
    Li, Zhengnong
    Zhao, Zhefei
    BUILDINGS, 2022, 12 (10)
  • [7] Field measurement of wind-induced stress on glass facade of a coastal high-rise building
    ZhengNong Li
    DieFeng Luo
    WenHai Shi
    ZhiQi Li
    XiaoHan Liang
    Science China Technological Sciences, 2011, 54 : 2587 - 2596
  • [8] Wind-induced fragility analysis of low-rise building envelope based on simplified progressive damage
    Wu F.
    Ji X.
    Huang G.
    Zhao Y.
    Jianzhu Jiegou Xuebao/Journal of Building Structures, 2021, 42 (05): : 32 - 39
  • [9] Wind-induced natural ventilation of re-entrant bays in a high-rise building
    Cheng, C. K. C.
    Lam, K. M.
    Leung, Y. T. A.
    Yang, K.
    Danny, H. W. Li
    Sherman, C. P. Cheung
    JOURNAL OF WIND ENGINEERING AND INDUSTRIAL AERODYNAMICS, 2011, 99 (2-3) : 79 - 90
  • [10] Interference Effects of Adjacent High-Rise Building on Wind-Induced Response of Low-Rise Flat Roof Building
    Chen, Bo
    Qin, Mengyi
    Du, Kun
    Yang, Qingshan
    INTERNATIONAL JOURNAL OF STRUCTURAL STABILITY AND DYNAMICS, 2022, 22 (03N04)