Fabrication and Characterization of Beam Quality Phantom for External Beam Radiotherapy

被引:0
作者
Boopathi, M. [1 ,2 ]
Khanna, D. [1 ]
Venkatraman, P. [3 ,5 ]
Sahay, Joshua [4 ]
Sureka, C.S. [5 ]
Raju, Varshini [6 ]
Aggarwal, Lalit Mohan [3 ]
Choudhary, Sunil [3 ]
机构
[1] Department of Physics, School of Engineering and Technology, Karunya Institute of Technology and Science, Tamilnadu, Coimbatore
[2] Dharan Cancer Specialty Center Pvt Ltd, Tamilnadu, Salem
[3] Department of Radiotherapy and Radiation Medicine, Banaras Hindu University, Varanasi
[4] HCG Cancer Hospital, Mansarovar, Jaipur
[5] Department of Medical Physics, Bharathiar University, Tamilnadu, Coimbatore
[6] Department of Medical Physics, PSG IMSR & Hospitals, Tamil Nadu, Coimbatore
关键词
10; Gelatin; Tissue Equivalent Phantom External Beam Radiotherapy TPR20;
D O I
10.22038/IJMP.2022.41985.1614
中图分类号
学科分类号
摘要
Introduction: Radiation dose measurement plays a major role in Radiation Dosimetry. Effective dose delivery to the patient is ensured with the recommendation of some protocol called Quality assurance (QA). It is necessary to confirm that the beam that is used for treatment is a good quality beam and it is given by beam quality factor TPR 20/10 which is one of the QA protocols. Material and Methods: In the present TPR20, 10 phantom both depth (20 and 10 cm) doses can be measured at the same procedure without changing any setup. As the reference condition is maintained, the Gelatin-based phantom is kept for irradiation in the Siemens Linear Accelerator (LINAC) machine. Initially Source Axis Distance (SAD) of 100 cm from the surface and 10×10 cm2 of field size. The measurement is taken by ion chamber at 10 and 20 cm depth in gantry angles 90° and 270° And the ratio of these values is taken and compared with the measurements of the water-based TPR phantom. Results: The values for the TPR20, 10 ratio for the Gelatin and water phantom are measured using the above method and the values are tabulated and compared. Likewise, the output measurements are done and tabulated for comparison. These measurements are carried out for several days to check the repeatability, and reproducibility of the phantom. Also, the measured set of values was analyzed using mean, median, standard deviation, etc. Conclusion: The fabricated phantom had good outcomes in its response. And the result projects that the phantom can be a better alternative for the other phantom materials and gelatin has more advantages over water, we conclude that gel can be used for better dosimetric procedures. © (2024), (Mashhad University of Medical Sciences). All rights reserved.
引用
收藏
页码:93 / 101
页数:8
相关论文
共 34 条
  • [11] Ceberg C, Johnsson S, Lind M, Knoos T., Prediction of stopping‐power ratios in flattening‐filter free beams, Medical physics, 37, 3, pp. 1164-1168, (2010)
  • [12] Kawrakow I., The EGSnrc code system, Monte Carlo simulation of electron and photon transport, (2001)
  • [13] Rogers DW, Faddegon BA, Ding GX, Ma CM, We J, Mackie TR., BEAM: a Monte Carlo code to simulate radiotherapy treatment units, Medical physics, 22, 5, pp. 503-524, (1995)
  • [14] Walters BR, Kawrakow I, Rogers DW., DOSXYZnrc User’s Manual, (2023)
  • [15] Constantin M, Perl J, LoSasso T, Salop A, Whittum D, Narula A, Svatos M, Keall PJ., Modeling the TrueBeam linac using a CAD to Geant4 geometry implementation: dose and IAEA‐compliant phase space calculations, Medical physics, 38, 7, pp. 4018-4024, (2011)
  • [16] Tonkopi E, McEwen MR, Walters BR, Kawrakow I., Influence of ion chamber response on in‐air profile measurements in megavoltage photon beams, Medical physics, 32, 9, pp. 2918-2927, (2005)
  • [17] McEwen MR, Kawrakow I, Ross CK., The effective point of measurement of ionization chambers and the build‐up anomaly in MV X‐ray beams, Medical physics, 35, 3, pp. 950-958, (2008)
  • [18] Rogers DW, Yang CL., Corrected relationship between and stopping‐power ratios, Medical Physics, 26, 4, pp. 538-540, (1999)
  • [19] Kalach NI, Rogers DW., Which accelerator photon beams are “clinic‐like” for reference dosimetry purposes, Medical physics, 30, 7, pp. 1546-1555, (2003)
  • [20] Titt U, Vassiliev ON, Ponisch F, Dong L, Liu H, Mohan R., A flattening filter free photon treatment concept evaluation with Monte Carlo, Medical physics, 33, pp. 1595-1602, (2006)