Effect of Respirophasic Displacement of the Inferior Vena Cava on Size Measurement in 2-D Ultrasound Imaging

被引:0
|
作者
Policastro, Piero [1 ]
Ermini, Leonardo [2 ]
Civera, Stefania [3 ]
Albani, Stefano [3 ,4 ]
Musumeci, Giuseppe [3 ]
Roatta, Silvestro [2 ]
Mesin, Luca [1 ]
机构
[1] Politecn Torino, Dept Elect & Telecommun, Math Biol & Physiol, Turin, Italy
[2] Univ Torino, Dept Neurosci, Turin, Italy
[3] Osped Ordine Mauriziano Torino, Div Cardiol, Turin, Italy
[4] Umberto Parini Reg Hosp, Div Cardiol, Aosta, Italy
关键词
Inferior vena cava; Ultrasound; Tracking;
D O I
10.1016/j.ultrasmedbio.2024.07.005
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Objective: Volume status assessment of a patient by ultrasound (US) imaging of the inferior vena cava (IVC) is important for the diagnosis and prognosis of various clinical conditions. In order to improve the clinical investigation of IVC, which is mainly based on unidirectional US (in M-mode), automated processing of 2-D US scans (in Bmode) has enabled tissue movement tracking on the visualized plane and can average this in various directions. However, IVC geometry outside of the visualized plane is not under control and could result in errors that have not yet been evaluated. Methods: We used a method that integrates information from long- and short-axis IVC views (simultaneously acquired in the X-plane) to assess challenges in IVC diameter estimations using 2-D US scans in eight healthy subjects. Results: Relative movements between the US probe and IVC induced the following problems when assessing IVC diameter via 2-D view: a median error (i.e., absolute difference with respect to diameter measured in the X-plane) of 17% using 2-D US scans in the long-axis view of the IVC affected by medio-lateral displacements (median: 4 mm); and a median error of 7% and 9% when measuring the IVC diameter from a short-axis view in the presence of pitch angle (median: 0.12 radians) and cranio-caudal movement (median: 15 mm), respectively. Conclusion: Relative movements in the IVC that are out of view of B-mode scans cannot be detected, which results in challenges in IVC diameter estimation.
引用
收藏
页码:1785 / 1792
页数:8
相关论文
共 42 条
  • [21] Application of ultrasound-guided inferior vena cava collapsibility measurement in volume assessment for patients undergoing single-shot spinal anesthesia in total hip arthroplasty
    Yang, Tao
    Huang, Chunyan
    Chen, Yulin
    Lei, Xuemin
    MEDICINE, 2024, 103 (45) : e40363
  • [22] Integrated Circuits for Volumetric Ultrasound Imaging With 2-D CMUT Arrays
    Bhuyan, Anshuman
    Choe, Jung Woo
    Lee, Byung Chul
    Wygant, Ira O.
    Nikoozadeh, Amin
    Oralkan, Omer
    Khuri-Yakub, Butrus T.
    IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS, 2013, 7 (06) : 796 - 804
  • [23] Underestimation of Flow Velocity in 2-D Super-Resolution Ultrasound Imaging
    Naji, Mostafa Amin
    Taghavi, Iman
    Thomsen, Erik Vilain
    Larsen, Niels Bent
    Jensen, Jorgen Arendt
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2024, 71 (12) : 1844 - 1854
  • [24] Costas Sparse 2-D Arrays for High-Resolution Ultrasound Imaging
    Masoumi, Mohammad Hadi
    Kaddoura, Tarek
    Zemp, Roger James
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2023, 70 (05) : 460 - 472
  • [25] Effects of Breath-Hold and Cardiac Cycle on the MRI Appearance of the Aorta and Inferior Vena Cava in T2 Abdominal Imaging
    Lisanti, Christopher J.
    Douglas, David B.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2009, 192 (05) : 1348 - 1358
  • [26] 2-D Arterial Wall Motion Imaging Using Ultrafast Ultrasound and Transverse Oscillations
    Salles, Sebastien
    Chee, Adrian J. Y.
    Garcia, Damien
    Yu, Alfred C. H.
    Vray, Didier
    Liebgott, Herve
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2015, 62 (06) : 1047 - 1058
  • [27] 2-D mapping of optical absorber size using photoacoustic graphic equalization imaging
    Basavarajappa, Lokesh
    Hoyt, Kenneth
    2021 IEEE UFFC LATIN AMERICA ULTRASONICS SYMPOSIUM (LAUS), 2021,
  • [28] Computer implementation in the reconstruction of 2-D flow velocity fields in ultrasound doppler color imaging
    Fei, DY
    Fu, CT
    Liu, DD
    COMPUTERS IN BIOLOGY AND MEDICINE, 1995, 25 (06) : 495 - 503
  • [29] ANALYSIS OF 2-D ULTRASOUND CARDIAC STRAIN IMAGING USING JOINT PROBABILITY DENSITY FUNCTIONS
    Ma, Chi
    Varghese, Tomy
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2014, 40 (06) : 1118 - 1132
  • [30] Quantification of murine myocardial infarct size using 2-D and 4-D high-frequency ultrasound
    Dann, Melissa M.
    Clark, Sydney Q.
    Trzaskalski, Natasha A.
    Earl, Conner C.
    Schepers, Luke E.
    Pulente, Serena M.
    Lennord, Ebonee N.
    Annamalai, Karthik
    Gruber, Joseph M.
    Cox, Abigail D.
    Lorenzen-Schmidt, Ilka
    Seymour, Richard
    Kim, Kyoung-Han
    Goergen, Craig J.
    Mulvihill, Erin E.
    AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY, 2022, 322 (03): : H359 - H372