摘要
The establishment of lightning protection design of household electrical appliances has been an important subject with progress of a highly informative society. As examining lightning protection design of household electrical appliances, the individual measure for power equipment, communication equipment, and household electrical appliances is insufficient. And it is important to evaluate and examine these synthetically as one circuit (low voltage distribution system). This report describes the results of the study to lightning protection design for low-voltage distribution systems experimentally, and the results of the lightning hazard evaluation based on experiments. © 2013 The Institute of Electrical Engineers of Japan.
引用
收藏
页码:575 / 578
页数:3
相关论文
共 50 条
  • [21] A Field Study of Lightning Phenomena on Low-Voltage Distribution Lines Including Residences
    Miyazaki, Teru
    Ishii, Tsunayoshi
    Okabe, Shigemitsu
    IEEE TRANSACTIONS ON POWER DELIVERY, 2011, 26 (01) : 289 - 297
  • [22] Lightning protection of overhead power distribution lines
    Yokoyama, Shigeru
    IEEJ TRANSACTIONS ON ELECTRICAL AND ELECTRONIC ENGINEERING, 2007, 2 (05) : 491 - 496
  • [23] EFFECTIVE LIGHTNING PROTECTION SCHEMES FOR DISTRIBUTION LINE
    MASAKI, T
    HIGUCHI, K
    YOKOI, Y
    ELECTRICAL ENGINEERING IN JAPAN, 1995, 115 (04) : 27 - 41
  • [24] EFFECT OF LIGHTNING OVERVOLTAGES ON LOW-VOLTAGE POWER DISTRIBUTION LINES DUE TO DIRECT LIGHTNING HITS TO OVERHEAD GROUND WIRE
    IMAI, Y
    FUJIWARA, N
    YOKOYAMA, H
    SHIMOMURA, T
    YAMAOKA, K
    ISHIBE, S
    ELECTRICAL ENGINEERING IN JAPAN, 1994, 114 (06) : 63 - 75
  • [25] Design of a lightning protection system for suspension bridges
    Koc, Cuneyt
    Kaymakci, Ozgur Turay
    JOURNAL OF POLYTECHNIC-POLITEKNIK DERGISI, 2024, 27 (04):
  • [26] Electromagnetic compatibility related to lightning protection systems
    Pack, S.
    ELEKTROTECHNIK UND INFORMATIONSTECHNIK, 2006, 123 (1-2): : 39 - 45
  • [27] Lightning characteristics as applied to protection of power systems
    Ishii, M
    IEEE/PES TRANSMISSION AND DISTRIBUTION CONFERENCE AND EXHIBITION 2002: ASIA PACIFIC, VOLS 1-3, CONFERENCE PROCEEDINGS: NEW WAVE OF T&D TECHNOLOGY FROM ASIA PACIFIC, 2002, : 526 - 528
  • [28] Mechanism of Pole-Mounted Transformer Damage by Backflow Lightning and Measures against the Damage on Low-Voltage Distribution Line
    Honda, Hideki
    Hongo, Yasuji
    Kado, Hiroyuki
    Yokoyama, Shigeu
    ELECTRICAL ENGINEERING IN JAPAN, 2010, 171 (02) : 1 - 11
  • [29] Designing Method of Insulation Strength and Lightning Protection for Overhead Power Distribution Lines
    Yokoyama, Shigeru
    Sato, Tomoyuki
    2018 34TH INTERNATIONAL CONFERENCE ON LIGHTNING PROTECTION (ICLP 2018), 2018,
  • [30] Research on lightning protection of overhead power distribution lines
    Yokoyama, Shigeru
    Sato, Tomoyuki
    Gaodianya Jishu/High Voltage Engineering, 2013, 39 (10): : 2317 - 2328