High-resolution perfusion imaging in rodents using pCASL at 9.4 T

被引:1
|
作者
Monteiro, Sara Pires [1 ,2 ,3 ]
Hirschler, Lydiane [4 ]
Barbier, Emmanuel L. [5 ]
Figueiredo, Patricia [2 ,3 ]
Shemesh, Noam [1 ]
机构
[1] Champalimaud Fdn, Champalimaud Res, Lisbon, Portugal
[2] Univ Lisbon, Inst Syst & Robot Lisboa, Lisbon, Portugal
[3] Univ Lisbon, Dept Bioengn, Inst Super Tecn, Lisbon, Portugal
[4] Leiden Univ, Dept Radiol, CJ Gorter MRI Ctr, Med Ctr, Leiden, Netherlands
[5] Univ Grenoble Alpes, Grenoble Inst Neurosci, Inserm, U1216, Grenoble, France
关键词
CBF; high-resolution; pCASL; perfusion; pre-clinical MRI; CEREBRAL-BLOOD-FLOW; QUANTITATIVE PERFUSION; ARTERIAL; MRI; CORTEX;
D O I
10.1002/nbm.5288
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Adequate perfusion is critical for maintaining normal brain function and aberrations thereof are hallmarks of many diseases. Pseudo-Continuous Arterial Spin Labeling (pCASL) MRI enables noninvasive quantitative perfusion mapping without contrast agent injection and with a higher signal-to-noise ratio (SNR) than alternative methods. Despite its great potential, pCASL remains challenging, unstable, and relatively low-resolution in rodents - especially in mice - thereby limiting the investigation of perfusion properties in many transgenic or other relevant rodent models of disease. Here, we address this gap by developing a novel experimental setup for high-resolution pCASL imaging in mice and combining it with the enhanced SNR of cryogenic probes. We show that our new experimental setup allows for optimal positioning of the carotids within the cryogenic coil, rendering labeling reproducible. With the proposed methodology, we managed to increase the spatial resolution of pCASL perfusion images by a factor of 15 in mice; a factor of 6 in rats is gained compared to the state of the art just by virtue of the cryogenic coil. We also show that the improved pCASL perfusion imaging allows much better delineation of specific brain areas, both in healthy animals as well as in rat and mouse models of stroke. Our results bode well for future high-definition pCASL perfusion imaging in rodents.
引用
收藏
页数:17
相关论文
共 50 条
  • [41] Polarized high-resolution imaging
    Stephen Ippolito
    Nature Photonics, 2008, 2 : 273 - 274
  • [42] High-resolution imaging ellipsometer
    Zhan, QW
    Leger, JR
    APPLIED OPTICS, 2002, 41 (22) : 4443 - 4450
  • [43] HIGH-RESOLUTION IMAGING OF FLAGELLA
    KOZMINSKI, KG
    METHODS IN CELL BIOLOGY, VOL 47, 1995, 47 : 263 - 271
  • [44] HIGH-RESOLUTION IMAGING OF OLIVINE
    RAHMAN, SH
    RICOULT, DL
    ZEITSCHRIFT FUR KRISTALLOGRAPHIE, 1986, 174 (1-4): : 76 - 78
  • [45] THE PROSPECTS FOR HIGH-RESOLUTION IMAGING
    COWLEY, JM
    MICRON, 1980, 11 (3-4) : 223 - 227
  • [46] High-resolution Photoacoustic Imaging
    Kong, Fanting
    Chen, Y. C.
    Lloyd, Harriet O.
    Silverman, Ronald H.
    Kim, Hyung
    Cannata, Jonathan M.
    Shung, K. Kirk
    2009 CONFERENCE ON LASERS AND ELECTRO-OPTICS AND QUANTUM ELECTRONICS AND LASER SCIENCE CONFERENCE (CLEO/QELS 2009), VOLS 1-5, 2009, : 403 - +
  • [47] PARATHYROID IMAGING - COMPARISON OF HIGH-RESOLUTION CT AND HIGH-RESOLUTION SONOGRAPHY
    STARK, DD
    GOODING, GAW
    MOSS, AA
    CLARK, OH
    OVENFORS, CO
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1983, 141 (04) : 633 - 638
  • [48] High-resolution dynamic susceptibility contrast perfusion imaging using higher-order temporal smoothness regularization
    Velikina, Julia V.
    Jung, Youngkyoo
    Field, Aaron S.
    Samsonov, Alexey A.
    MAGNETIC RESONANCE IN MEDICINE, 2023, 89 (01) : 112 - 127
  • [49] HIGH-RESOLUTION SURFACE IMAGING
    MARKS, LD
    ACTA CRYSTALLOGRAPHICA SECTION A, 1984, 40 : C390 - C390
  • [50] High-resolution imaging in epilepsy
    Bronen, RA
    Knowlton, T
    Garwood, M
    Maravilla, KR
    Jack, CR
    EPILEPSIA, 2002, 43 : 11 - 18