High-resolution perfusion imaging in rodents using pCASL at 9.4 T

被引:1
|
作者
Monteiro, Sara Pires [1 ,2 ,3 ]
Hirschler, Lydiane [4 ]
Barbier, Emmanuel L. [5 ]
Figueiredo, Patricia [2 ,3 ]
Shemesh, Noam [1 ]
机构
[1] Champalimaud Fdn, Champalimaud Res, Lisbon, Portugal
[2] Univ Lisbon, Inst Syst & Robot Lisboa, Lisbon, Portugal
[3] Univ Lisbon, Dept Bioengn, Inst Super Tecn, Lisbon, Portugal
[4] Leiden Univ, Dept Radiol, CJ Gorter MRI Ctr, Med Ctr, Leiden, Netherlands
[5] Univ Grenoble Alpes, Grenoble Inst Neurosci, Inserm, U1216, Grenoble, France
关键词
CBF; high-resolution; pCASL; perfusion; pre-clinical MRI; CEREBRAL-BLOOD-FLOW; QUANTITATIVE PERFUSION; ARTERIAL; MRI; CORTEX;
D O I
10.1002/nbm.5288
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Adequate perfusion is critical for maintaining normal brain function and aberrations thereof are hallmarks of many diseases. Pseudo-Continuous Arterial Spin Labeling (pCASL) MRI enables noninvasive quantitative perfusion mapping without contrast agent injection and with a higher signal-to-noise ratio (SNR) than alternative methods. Despite its great potential, pCASL remains challenging, unstable, and relatively low-resolution in rodents - especially in mice - thereby limiting the investigation of perfusion properties in many transgenic or other relevant rodent models of disease. Here, we address this gap by developing a novel experimental setup for high-resolution pCASL imaging in mice and combining it with the enhanced SNR of cryogenic probes. We show that our new experimental setup allows for optimal positioning of the carotids within the cryogenic coil, rendering labeling reproducible. With the proposed methodology, we managed to increase the spatial resolution of pCASL perfusion images by a factor of 15 in mice; a factor of 6 in rats is gained compared to the state of the art just by virtue of the cryogenic coil. We also show that the improved pCASL perfusion imaging allows much better delineation of specific brain areas, both in healthy animals as well as in rat and mouse models of stroke. Our results bode well for future high-definition pCASL perfusion imaging in rodents.
引用
收藏
页数:17
相关论文
共 50 条
  • [21] HIGH-RESOLUTION IMAGING USING PUPIL SEGMENTATION
    SEBAG, J
    ARNAUD, J
    LELIEVRE, G
    NIETO, JL
    LECOARER, E
    JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1990, 7 (07): : 1237 - 1242
  • [22] High-resolution multispectral imaging using a photodiode
    Bian, Liheng
    Suo, Jinli
    Chen, Feng
    Dai, Qionghai
    HIGH-SPEED BIOMEDICAL IMAGING AND SPECTROSCOPY III: TOWARD BIG DATA INSTRUMENTATION AND MANAGEMENT, 2018, 10505
  • [23] High-Resolution Mapping of Neuronal Activation with Balanced SSFP at 9.4 Tesla
    Scheffler, Klaus
    Ehses, Philipp
    MAGNETIC RESONANCE IN MEDICINE, 2016, 76 (01) : 163 - 171
  • [24] Insights into hippocampal perfusion using high-resolution, multi-modal 7T MRI
    Haast, Roy A. M.
    Kashyap, Sriranga
    Ivanov, Dimo
    Yousif, Mohamed D.
    Dekraker, Jordan
    Poser, Benedikt A.
    Khan, Ali R.
    PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2024, 121 (11)
  • [25] High-resolution sodium imaging of human brain at 7 T
    Qian, Yongxian
    Zhao, Tiejun
    Zheng, Hai
    Weimer, Jonathan
    Boada, Fernando E.
    MAGNETIC RESONANCE IN MEDICINE, 2012, 68 (01) : 227 - 233
  • [26] Sensitivity and specificity of high-resolution balanced steady-state free precession fMRI at high field of 9.4 T
    Park, Sung-Hong
    Kim, Tae
    Wang, Ping
    Kim, Seong-Gi
    NEUROIMAGE, 2011, 58 (01) : 168 - 176
  • [27] High-resolution imaging using a translating coded aperture
    Mahalanobis, Abhijit
    Shilling, Richard
    Muise, Robert
    Neifeld, Mark
    OPTICAL ENGINEERING, 2017, 56 (08)
  • [28] High-Resolution Ultrasound Imaging Using Random Interference
    Ni, Pavel
    Lee, Heung-No
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2020, 67 (09) : 1785 - 1799
  • [29] High-resolution solar imaging using blind deconvolution
    Hartkorn, K
    DYNAMIC SUN, PROCEEDINGS, 2001, 259 : 211 - 214
  • [30] High-Resolution MREIT using Low Imaging Currents
    Woo, Eung Je
    2011 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2011, : 7025 - 7028