The wavelet transform assisted laser-induced fluorescence detector with high sensitivity

被引:0
|
作者
Zheng, Chao [1 ,2 ]
Wang, Chuanliang [2 ,4 ]
Sha, Tao [2 ]
Wang, Guiqiu [1 ]
Guan, Yafeng [2 ,5 ]
He, Hui [3 ]
Jin, Shi [3 ]
Geng, Xuhui [2 ]
机构
[1] Dalian Maritime Univ, Sch Sci, 1 Linghai Rd, Dalian 116024, Peoples R China
[2] Chinese Acad Sci, Dalian Inst Chem Phys, CAS Key Lab Separat Sci Analyt Chem, Key Lab Deep Sea Composit Detect Technol Liaoning, 457 Zhongshan Rd, Dalian 116023, Peoples R China
[3] Dalian Med Univ, Affiliated Hosp 1, Dalian, Peoples R China
[4] Univ Chinese Acad Sci, Beijing 100049, Peoples R China
[5] Chinese Acad Sci, Inst Deep Sea Sci & Engn, 28 Luhuitou Rd, Sanya 572000, Peoples R China
关键词
Laser-induced fluorescence; Inverted suction injection; Wavelet transform; High sensitivity; Good reproducibility; LIGHT-EMITTING DIODE; CAPILLARY-ELECTROPHORESIS; SYSTEM; MICRODEVICE; EXTRACTION; SCALE;
D O I
10.1016/j.talanta.2024.127257
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A wavelet transform assisted laser-induced fluorescence detector with high sensitivity was developed and evaluated. An unconventional microscope objective with a numerical aperture (NA) of 0.5 and a working distance (WD) of 4.0 mm was employed, which improved fluorescence collection efficiency, increasing SNR to about 5 times. An aspherical lens was used in the collection optical path to reduce the diameter of the fluorescence imaging size, increasing the SNR to about 1.3 times. The "inverted suction injection" method of flow injection analysis (FIA) was used for the first time in LIF evaluation to reduce contamination errors and improve the accuracy of ultra-trace analysis. The wavelet transform method was proposed for data processing of LIF signals, which can reduce noise from 0.009 mV to 0.002 mV without changing the peak height and peak width. The limit of detection (LOD, 3 sigma method) for sodium fluorescein was 9.7 x 10-14 M or 3.9 fluorescein molecules in 68 pL detection volume, which was the lowest level of LIFs evaluated by FIA mode. The LIF combined with capillary electrophoresis (CE) achieved an LOD of 4.9 x 10-15 M for fluorescein sodium, which is the best level that has been reported.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] A handheld laser-induced fluorescence detector for multiple applications
    Fang, Xiao-Xia
    Li, Han-Yang
    Fang, Pan
    Pan, Jian-Zhang
    Fang, Qun
    TALANTA, 2016, 150 : 135 - 141
  • [2] Compact Laser-Induced Fluorescence Detector with Adjustable Laser Focal Spot for Multiple Purposes
    Xu, Zihe
    Chen, Xi
    Liu, Fangwu
    SENSORS, 2024, 24 (19)
  • [3] Interfacing a high-sensitivity, near-infrared laser-induced fluorescence detector with a commercial capillary electrophoresis instrument
    Baars, MJ
    Patonay, G
    APPLIED SPECTROSCOPY, 1998, 52 (12) : 1619 - 1622
  • [4] Application of Wavelet Transform in Laser-Induced Breakdown Spectra Compression
    Jiang Mei-cheng
    Lu Ji-dong
    Yao Shun-chun
    Pan Sheng-hua
    Chen Kai
    Dong Mei-rong
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2010, 30 (10) : 2797 - 2801
  • [5] Comparative Study on Determination of Proteins by High Performance Liquid Chromatography with Ultraviolet or Laser-Induced Fluorescence as Detector
    Ma Li-Min
    Song Lun
    Qian Jun-Hong
    Zhang Ling-Yi
    Lan Min-Bo
    Zhang Wei-Bing
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2011, 39 (07) : 1027 - 1032
  • [6] Determination of Norfloxacin in Food by Capillary Electrophoresis Immunoassay with Laser-Induced Fluorescence Detector
    Cuicui Liu
    Xue Feng
    Hailong Qian
    Guozhen Fang
    Shuo Wang
    Food Analytical Methods, 2015, 8 : 596 - 603
  • [7] Determination of Norfloxacin in Food by Capillary Electrophoresis Immunoassay with Laser-Induced Fluorescence Detector
    Liu, Cuicui
    Feng, Xue
    Qian, Hailong
    Fang, Guozhen
    Wang, Shuo
    FOOD ANALYTICAL METHODS, 2015, 8 (03) : 596 - 603
  • [8] A compactly integrated laser-induced fluorescence detector for microchip electrophoresis
    Li, HF
    Lin, JM
    Su, RG
    Uchiyama, K
    Hobo, T
    ELECTROPHORESIS, 2004, 25 (12) : 1907 - 1915
  • [9] Sheath-flow cuvette for high-sensitivity laser-induced fluorescence detection in capillary electrophoresis
    Sobhani, Kimia
    Michels, David A.
    Dovichi, Norman J.
    APPLIED SPECTROSCOPY, 2007, 61 (07) : 777 - 779
  • [10] Lead of detection in rhododendron leaves using laser-induced breakdown spectroscopy assisted by laser-induced fluorescence
    Zhu, Chenwei
    Tang, Zhiyang
    Li, Qingzhou
    Zhou, Ran
    Lv, Jiaxin
    Zhang, Wen
    Zhan, Kaiping
    Li, Xiangyou
    Zeng, Xiaoyan
    SCIENCE OF THE TOTAL ENVIRONMENT, 2020, 738