The wavelet transform assisted laser-induced fluorescence detector with high sensitivity

被引:0
|
作者
Zheng, Chao [1 ,2 ]
Wang, Chuanliang [2 ,4 ]
Sha, Tao [2 ]
Wang, Guiqiu [1 ]
Guan, Yafeng [2 ,5 ]
He, Hui [3 ]
Jin, Shi [3 ]
Geng, Xuhui [2 ]
机构
[1] Dalian Maritime Univ, Sch Sci, 1 Linghai Rd, Dalian 116024, Peoples R China
[2] Chinese Acad Sci, Dalian Inst Chem Phys, CAS Key Lab Separat Sci Analyt Chem, Key Lab Deep Sea Composit Detect Technol Liaoning, 457 Zhongshan Rd, Dalian 116023, Peoples R China
[3] Dalian Med Univ, Affiliated Hosp 1, Dalian, Peoples R China
[4] Univ Chinese Acad Sci, Beijing 100049, Peoples R China
[5] Chinese Acad Sci, Inst Deep Sea Sci & Engn, 28 Luhuitou Rd, Sanya 572000, Peoples R China
关键词
Laser-induced fluorescence; Inverted suction injection; Wavelet transform; High sensitivity; Good reproducibility; LIGHT-EMITTING DIODE; CAPILLARY-ELECTROPHORESIS; SYSTEM; MICRODEVICE; EXTRACTION; SCALE;
D O I
10.1016/j.talanta.2024.127257
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A wavelet transform assisted laser-induced fluorescence detector with high sensitivity was developed and evaluated. An unconventional microscope objective with a numerical aperture (NA) of 0.5 and a working distance (WD) of 4.0 mm was employed, which improved fluorescence collection efficiency, increasing SNR to about 5 times. An aspherical lens was used in the collection optical path to reduce the diameter of the fluorescence imaging size, increasing the SNR to about 1.3 times. The "inverted suction injection" method of flow injection analysis (FIA) was used for the first time in LIF evaluation to reduce contamination errors and improve the accuracy of ultra-trace analysis. The wavelet transform method was proposed for data processing of LIF signals, which can reduce noise from 0.009 mV to 0.002 mV without changing the peak height and peak width. The limit of detection (LOD, 3 sigma method) for sodium fluorescein was 9.7 x 10-14 M or 3.9 fluorescein molecules in 68 pL detection volume, which was the lowest level of LIFs evaluated by FIA mode. The LIF combined with capillary electrophoresis (CE) achieved an LOD of 4.9 x 10-15 M for fluorescein sodium, which is the best level that has been reported.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] High-sensitivity determination of available cobalt in soil using laser-induced breakdown spectroscopy assisted with laser-induced fluorescence
    Zhou, Ran
    Liu, Ke
    Tang, Zhiyang
    Gao, Peiyuan
    Yan, Jiujiang
    Li, Xiangyou
    APPLIED OPTICS, 2021, 60 (29) : 9062 - 9066
  • [2] Determination of Molybdenum, Nickel, and Chromium in Low-alloy Steels Using Laser-induced Breakdown Spectroscopy Assisted with Laser-induced Fluorescence and Discrete Wavelet Transform
    Zhao, Nan
    Luo, Zeren
    Li, Jiaming
    Ma, Qiongxiong
    Guo, Liang
    Shan, Chun
    Zhang, Qingmao
    ATOMIC SPECTROSCOPY, 2023, 44 (04) : 219 - 226
  • [3] Application of the wavelet transform for feature extraction in the analysis of hyperspectral laser-induced fluorescence data
    Sobolev, Innokenti
    Babichenko, Sergey
    INTERNATIONAL JOURNAL OF REMOTE SENSING, 2013, 34 (20) : 7218 - 7235
  • [4] HIGH-SENSITIVITY LASER-INDUCED FLUORESCENCE DETECTION FOR CAPILLARY ELECTROPHORESIS
    ZHANG, JZ
    CHEN, DY
    WU, S
    HARKE, HR
    DOVICHI, NJ
    CLINICAL CHEMISTRY, 1991, 37 (09) : 1492 - 1496
  • [5] LASER-INDUCED FLUORESCENCE AND HIGH-RESOLUTION FOURIER-TRANSFORM SPECTROMETRY
    VERGES, J
    AMIOT, C
    BACIS, R
    ROSS, AJ
    SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 1995, 51 (07): : 1191 - 1215
  • [6] A handheld laser-induced fluorescence detector for multiple applications
    Fang, Xiao-Xia
    Li, Han-Yang
    Fang, Pan
    Pan, Jian-Zhang
    Fang, Qun
    TALANTA, 2016, 150 : 135 - 141
  • [7] Interfacing a high-sensitivity, near-infrared laser-induced fluorescence detector with a commercial capillary electrophoresis instrument
    Baars, MJ
    Patonay, G
    APPLIED SPECTROSCOPY, 1998, 52 (12) : 1619 - 1622
  • [8] Application of Wavelet Transform in Laser-Induced Breakdown Spectra Compression
    Jiang Mei-cheng
    Lu Ji-dong
    Yao Shun-chun
    Pan Sheng-hua
    Chen Kai
    Dong Mei-rong
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2010, 30 (10) : 2797 - 2801
  • [9] HIGH-SENSITIVITY LASER-INDUCED FLUORESCENCE DETECTION IN CAPILLARY ZONE ELECTROPHORESIS
    NICKERSON, B
    JORGENSON, JW
    JOURNAL OF HIGH RESOLUTION CHROMATOGRAPHY & CHROMATOGRAPHY COMMUNICATIONS, 1988, 11 (12): : 878 - 881
  • [10] LASER-INDUCED FLUORESCENCE AND HIGH-RESOLUTION FOURIER-TRANSFORM SPECTROSCOPY (LIFFTS)
    VERGES, J
    AMIOT, C
    JOURNAL DE PHYSIQUE, 1987, 48 (C-7): : 595 - 600