Seismic demand-oriented design of hybrid base-isolated building with the tuned inerter eddy current damper

被引:2
|
作者
Li, Dawei [1 ,2 ]
Bai, He [1 ]
Lou, Yu [2 ]
Han, Jianping [1 ]
机构
[1] Lanzhou Univ Technol, Sch Civil Engn, Lanzhou 730050, Peoples R China
[2] China Elect Engn Design Inst Co Ltd, Beijing 100142, Peoples R China
关键词
Base isolation system; Tuned inerter eddy current damper; Inerter; Nonlinear damping; Optimal design; MASS DAMPERS; VIBRATION CONTROL; IMPACT RESPONSE; PERFORMANCE;
D O I
10.1016/j.soildyn.2024.109068
中图分类号
P5 [地质学];
学科分类号
0709 ; 081803 ;
摘要
A novel tuned inerter eddy current damper (TIECD) is proposed to mitigate isolator deformation in a base isolation (BI) system subjected to earthquake ground motions. Considering the topological similarity and damping equivalent criteria, the design formulations of the tuned inerter damper are extended to determine the optimal parameters of the TIECD. A combination of iterative updating, response-spectrum analysis, and complex complete quadratic-combination measures is established to realize the seismic demand-oriented design framework of the TIECD. Furthermore, the proposed design framework incorporates the equivalent stiffness and damping of a lead rubber bearing to approximate the design parameters of the TIECD in a nonlinear BI system. Finally, the feasibility and effectiveness of the designed TIECD are validated using a nine-story base isolated benchmark model with lead rubber bearings. Numerical simulation results indicate that the designed TIECD can significantly suppress the displacement, acceleration, and base shear demands of the hybrid BI system. Compared with the viscous damping in the tuned inerter damper, the designed TIECD exhibits a significantly enhanced level of damping owing to the combination of a lower damping force and a larger deformation.
引用
收藏
页数:14
相关论文
共 50 条
  • [41] Soil-dependent optimum design of a new passive vibration control system combining seismic base isolation with tuned inerter damper
    De Domenico, D.
    Impollonia, N.
    Ricciardi, G.
    SOIL DYNAMICS AND EARTHQUAKE ENGINEERING, 2018, 105 : 37 - 53
  • [42] Vibration Control of a Two-Story Base-Isolated Building using a New Tuned Mass Multi-Sliding Friction Damper
    Amjadian, Mohsen
    Haider, Syed Muhammad Bilal
    ACTIVE AND PASSIVE SMART STRUCTURES AND INTEGRATED SYSTEMS XVII, 2023, 12483
  • [43] Optimal design of Magnetorheological damper for seismic response reduction of Base-Isolated structures considering Soil-Structure interaction
    Abdeddaim, Mahdi
    Djerouni, Salah
    Ounis, Abdelhafid
    Athamnia, Brahim
    Farsangi, Ehsan Noroozinejad
    STRUCTURES, 2022, 38 : 733 - 752
  • [44] A Hybrid Probability-Convex Model for the Seismic Demand Analysis of Bearing Displacement in the Benchmark Base-Isolated Structure
    Fan, Jian
    Zhang, Yanping
    ADVANCES IN STRUCTURAL ENGINEERING, 2014, 17 (07) : 1061 - 1073
  • [45] A Sensitivity Analysis Approach for Assessing the Effect of Design Parameters in Reducing Seismic Demand of Base-Isolated Storage Racks
    Alvarez, Oscar
    Munoz, Enrique
    Maureira-Carsalade, Nelson
    Roco-Videla, Angel
    APPLIED SCIENCES-BASEL, 2021, 11 (23):
  • [46] SEISMIC ANALYSIS OF NONLINEARLY BASE-ISOLATED SOIL STRUCTURE INTERACTING REACTOR BUILDING BY WAY OF THE HYBRID FREQUENCY TIME-DOMAIN PROCEDURE
    DARBRE, GR
    EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 1990, 19 (05): : 725 - 738
  • [47] Seismic Fragility Assessment of a Base-Isolated RC Frame Building Using Direct Displacement-Based Design and Force-Based Design
    Jain, Ritika
    Gondaliya, Kaushik M.
    Palsanawala, Twinsy N.
    Vasanwala, Sandip A.
    Bhaiya, Vishisht
    JOURNAL OF STRUCTURAL DESIGN AND CONSTRUCTION PRACTICE, 2025, 30 (01):
  • [48] Seismic response characteristics of base-isolated AP1000 nuclear shield building subjected to beyond-design basis earthquake shaking
    Wang, Dayang
    Zhuang, Chuli
    Zhang, Yongshan
    NUCLEAR ENGINEERING AND TECHNOLOGY, 2018, 50 (01) : 170 - 181
  • [49] Use of Simplified Nonlinear Response History Analysis to Inform Equivalent Lateral Force Procedure: A Hybrid Approach to Base-Isolated Building Design
    Wray, Gordon
    Sinclair, Mark
    Pedersen, Dallin
    Maxfield, Brent
    Moore, Erik
    STRUCTURES CONGRESS 2015, 2015, : 2532 - 2544
  • [50] Seismic analysis of non-linearly base-isolated soil-structure interacting reactor building by way of the hybrid frequency-time-domain procedure
    Darbre, Georges R.
    Earthquake Engineering & Structural Dynamics, 1990, 19 (05): : 725 - 738