Moment capacity of cold-formed steel trusses with Howick Rivet Connectors: Tests, modelling and design

被引:2
作者
Wang, Wei [1 ]
Roy, Krishanu [1 ]
Rezaeian, Hooman [2 ]
Fang, Zhiyuan [1 ]
Lim, James B. P. [1 ]
机构
[1] Univ Waikato, Sch Engn, Hamilton, New Zealand
[2] Howick Ltd, Auckland, New Zealand
关键词
Cold-formed steel; Experimental investigation; Finite element analysis; Howick Rivet Connectors; Moment capacity; Trusses; BEHAVIOR; JOINTS;
D O I
10.1016/j.engstruct.2024.119171
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Cold-formed steel (CFS) trusses are increasingly used in lightweight building construction. A new type of pin- jointed connector, known as the Howick Rivet Connectors (HRCs), has been developed for CFS trusses. Previous studies focused on testing T-stub connections and shear strengths of CFS trusses with HRCs, providing insights into their structural performance and shear capacity. This paper extends the research by testing ten new CFS trusses with HRCs to determine their moment capacity. The study involved two different cross-sections: lipped channel sections and hat sections, used as truss chords. Variations in the number and locations of lateral supports were introduced to simulate different boundary conditions. A parametric study explored the effects of span-height ratio and variability in lateral support locations on truss strength and failure modes. Finally, the trusses with lipped section chords were designed according to the American Iron and Steel Institute (AISI 2016) and Australia/New Zealand standards (AS/NZS 2018), achieving an average test-to-design strength ratio of 0.86.
引用
收藏
页数:16
相关论文
共 50 条
  • [21] Simplified calculation method for flexural moment capacity of cold-formed steel built-up section beams
    Yao, Xinmei
    Zhou, Xuhong
    Shi, Yu
    Guan, Yu
    Zou, Yuxuan
    ADVANCES IN STRUCTURAL ENGINEERING, 2020, 23 (14) : 3153 - 3167
  • [22] Bending Moment Capacity of Cold-Formed Steel Built-Up Beams
    Mohamed Ghannam
    International Journal of Steel Structures, 2019, 19 : 660 - 671
  • [23] Local Buckling in Cold-Formed Steel Moment-Resisting Bolted Connections: Behavior, Capacity, and Design
    Mojtabaei, Seyed Mohamad
    Becque, Jurgen
    Hajirasouliha, Iman
    JOURNAL OF STRUCTURAL ENGINEERING, 2020, 146 (09)
  • [24] Failure capacities of cold-formed steel roof trusses end-connections
    Bondok, D. H.
    Salim, H. A.
    THIN-WALLED STRUCTURES, 2017, 121 : 57 - 66
  • [25] Push-out tests on bolted shear connectors in composite cold-formed steel beams
    Hosseinpour, Mahmoud
    Zeynalian, Mehran
    Ataei, Abdoreza
    Daei, Maryam
    THIN-WALLED STRUCTURES, 2021, 164
  • [26] Push out tests on various shear connectors used for cold-formed steel composite beam
    Rajendran, Senthilkumar
    Perumalsamy, Jayabalan
    Mohanraj, Divya
    STEEL AND COMPOSITE STRUCTURES, 2022, 42 (03) : 315 - 323
  • [27] Tests and Finite Element Modelling of Cold-Formed Steel Zed and Hat Section Columns Under Axial Compression
    Ananthi, G. Beulah Gnana
    Roy, Krishanu
    Lim, James B. P.
    INTERNATIONAL JOURNAL OF STEEL STRUCTURES, 2021, 21 (04) : 1305 - 1331
  • [28] Seismic design of cold-formed steel beams based on flexural capacity-ductility - Energy dissipation
    Yuting Zhong
    Yingkai Liu
    Shen Liu
    Ruoqiang Feng
    THIN-WALLED STRUCTURES, 2023, 192
  • [29] Tests of cold-formed stainless steel tubular flexural members
    Zhou, F
    Young, B
    THIN-WALLED STRUCTURES, 2005, 43 (09) : 1325 - 1337
  • [30] Tests of cold-formed duplex stainless steel SHS beam-columns
    Lui, Wing-Man
    Ashraf, Mahmud
    Young, Ben
    ENGINEERING STRUCTURES, 2014, 74 : 111 - 121