Investigations on overvoltages in the overhead contact system of ÖBB

被引:0
|
作者
Wallnberger, Gerald [1 ]
Punz, Gerold
Pechlaner, Hans [2 ]
Meyer, Markus [3 ]
机构
[1] ÖBB-Infrastruktur Betrieb AG, Elisabethstr. 9, 1010 Wien, Austria
[2] ÖBB-Infrastruktur Bau AG, Kraftwerke, Claudiastr. 2, 6020 Innsbruck, Austria
[3] Emkamatik GmbH, Rebbergstr. 20a, 5430 Wettingen, Switzerland
来源
eb - Elektrische Bahnen | 2006年 / 104卷 / 11期
关键词
Electric generators - Electric potential - Electric power systems - Electric traction - Electric transformers - Frequency response - Harmonic generation - Overhead lines;
D O I
暂无
中图分类号
学科分类号
摘要
The a.c. traction power supply system of ÖBB (Austrian Federal Railways) consisting of generators, trac-tion power lines, transformers and the overhead contact line contains points of resonance. The feedback of harmonics of the static converter traction vehicles may cause network instabilities resulting in overvoltages in the power supply system. Whether a traction vehicle can induce resonances in the power supply system will depend in the frequency response of its input admittance. Criteria for static converter traction vehicles were developed within the scope of an investigation.
引用
收藏
页码:536 / 541
相关论文
共 50 条
  • [31] Implementation of optimization of the uplift amount measurement system of overhead contact line
    Park, Young
    Lee, Kiwon
    Park, Chulmin
    Kwon, Sam-Young
    Transactions of the Korean Institute of Electrical Engineers, 2013, 62 (06): : 886 - 890
  • [32] Analytical investigation of parameters effect on lightning-induced overvoltages on overhead lines
    Bidi M.
    Latreche M.H.
    International Journal of System Assurance Engineering and Management, 2016, 7 (1) : 114 - 120
  • [33] Simulation and visualisation of the dynamic behaviour of an overhead power system with contact breaking
    Yagi, T
    Stensson, A
    Hardell, C
    VEHICLE SYSTEM DYNAMICS, 1996, 25 (01) : 31 - 49
  • [34] Discussion on the Seismic Fortification Strategy for Overhead Contact System in Electrified Railway
    Yang, Jia
    Chen, Fenfei
    Chen, Ke
    Lu, Xiaobing
    Journal of Railway Engineering Society, 2021, 38 (10) : 85 - 89
  • [35] CONTRIBUTION TO UNDERSTANDING THE OSCILLATIONS OF AN OVERHEAD CONTACT SYSTEM FOR ELECTRIC RAILWAY TRACTION
    BUCKSCH, R
    1979, 52 (05): : 250 - 262
  • [36] Railway overhead contact wire monitoring system by means of FBG sensors
    Lupi, Carla
    Felli, Ferdinando
    Ciro, Erwin
    Paris, Claudio
    Vendittozzi, Cristian
    FRATTURA ED INTEGRITA STRUTTURALE-FRACTURE AND STRUCTURAL INTEGRITY, 2021, 15 (57): : 246 - 258
  • [37] Availability of an Overhead Contact Line System for the Electrification of Road Freight Transport
    Wilke, Juergen K.
    Schoepp, Ferdinand
    Linke, Regina
    Bremer, Laurenz
    Scheyltjens, Maya Ada
    Buggenhout, Niki
    Kassens-Noor, Eva
    SUSTAINABILITY, 2024, 16 (15)
  • [38] Overhead contact line inspection system by rail-and-road car
    Kusumi, Shunichi
    Nezu, Kazuyoshi
    Nagasawa, Hiroki
    Quarterly Report of RTRI (Railway Technical Research Institute) (Japan), 2000, 41 (04): : 169 - 172
  • [39] Calculation of Lightning Induced Overvoltages on Overhead Lines: Model and Interface With MATLAB/Simulink
    Liu, Xin
    Fan, Ziwei
    Liang, Guishu
    Wang, Tao
    IEEE ACCESS, 2018, 6 : 47308 - 47318
  • [40] Calculation of 10 kV overhead transmission lines failures caused by induced overvoltages
    Malysheva, EP
    MODERN TECHNIQUES AND TECHNOLOGY: MTT' 2000, 2000, : 14 - 16