Investigations on overvoltages in the overhead contact system of ÖBB

被引:0
|
作者
Wallnberger, Gerald [1 ]
Punz, Gerold
Pechlaner, Hans [2 ]
Meyer, Markus [3 ]
机构
[1] ÖBB-Infrastruktur Betrieb AG, Elisabethstr. 9, 1010 Wien, Austria
[2] ÖBB-Infrastruktur Bau AG, Kraftwerke, Claudiastr. 2, 6020 Innsbruck, Austria
[3] Emkamatik GmbH, Rebbergstr. 20a, 5430 Wettingen, Switzerland
来源
eb - Elektrische Bahnen | 2006年 / 104卷 / 11期
关键词
Electric generators - Electric potential - Electric power systems - Electric traction - Electric transformers - Frequency response - Harmonic generation - Overhead lines;
D O I
暂无
中图分类号
学科分类号
摘要
The a.c. traction power supply system of ÖBB (Austrian Federal Railways) consisting of generators, trac-tion power lines, transformers and the overhead contact line contains points of resonance. The feedback of harmonics of the static converter traction vehicles may cause network instabilities resulting in overvoltages in the power supply system. Whether a traction vehicle can induce resonances in the power supply system will depend in the frequency response of its input admittance. Criteria for static converter traction vehicles were developed within the scope of an investigation.
引用
收藏
页码:536 / 541
相关论文
共 50 条
  • [21] Lightning-induced overvoltages on overhead lines: Modelling and experimental validation
    Mimouni, Abdenbi
    Azzouz, Zin E.
    Ghemri, Boualem
    JOURNAL OF ELECTRICAL ENGINEERING-ELEKTROTECHNICKY CASOPIS, 2007, 58 (03): : 146 - 151
  • [22] Determination and Optimization of the Maintenance Frequencies in the Overhead Contact Line System
    Zorita, A. L.
    Duque, O.
    Fernandez, M. A.
    Garcia-Escudero, L. A.
    JOURNAL OF TRANSPORTATION ENGINEERING, 2010, 136 (11) : 964 - 972
  • [23] A Novel Fault Prevention Model for Metro Overhead Contact System
    Liu, Yigu
    Gao, Shibin
    Yu, Long
    IEEE ACCESS, 2019, 7 : 91850 - 91859
  • [24] Revision of lightning protection map for overhead contact line system
    Nakayama, Masahiro
    Furuyama, Yukio
    Aoyagi, Haruki
    Katou, Hiroshi
    Nakamura, Takehiko
    Iino, Yuuki
    Yamazaki, Takeshi
    Hayashiya, Hitoshi
    Tsuchizawa, Dan
    2016 33RD INTERNATIONAL CONFERENCE ON LIGHTNING PROTECTION (ICLP), 2016,
  • [25] IMPROVED OVERHEAD CONTACT SYSTEM OPERATION WITH INCLINED PENDULUM SUSPENSION
    White, Paul F.
    Keo, Dada S.
    Kola, Gerti
    PROCEEDINGS OF THE ASME JOINT RAIL CONFERENCE, 2018, 2018,
  • [26] Overhead Contact System of Linea Bananera in Costa Rica.
    Noeding, Manfred
    Zeitschrift fuer Eisenbahnwesen und Verkehrstechnik - Glasers Annalen, 1983, 107 (07): : 208 - 213
  • [27] A new contact force measuring method for overhead catenary system
    Tan, Mengying
    Zou, Dong
    Zhou, Ning
    Li, Ruiping
    Zhang, Weihua
    Li, Yan
    DYNAMICS OF VEHICLES ON ROADS AND TRACKS, VOL 2, 2018, : 1341 - 1345
  • [28] Evaluation of Lightning Overvoltages for Overhead Transmission Lines Using Unscented Transform
    Coelho, Alex J. C.
    Moura, Rodolfo A. R.
    Assis, Fernando A.
    Schroeder, Marco Aurelio O.
    Yuan, Xinyi
    Hooshyar, Ali
    IEEE TRANSACTIONS ON POWER DELIVERY, 2023, 38 (01) : 746 - 749
  • [29] Lightning-Induced Overvoltages on Overhead Medium-Voltage Lines
    Piantini, Alexandre
    2016 IEEE INTERNATIONAL CONFERENCE ON HIGH VOLTAGE ENGINEERING AND APPLICATION (ICHVE), 2016,
  • [30] Statistical evaluation of lightning overvoltages on overhead distribution lines using neural networks
    Martinez, JA
    Gonzalez-Molina, F
    IEEE TRANSACTIONS ON POWER DELIVERY, 2005, 20 (03) : 2219 - 2226