On-line monitoring system for the temperature of the contact of circuit breaker and busbar based on bluetooth technique

被引:0
|
作者
Deng, Ben-Zai [1 ]
Hu, Tao [1 ]
机构
[1] Changsha University of Science and Technology, Changsha 410076, China
来源
Gaoya Dianqi/High Voltage Apparatus | 2006年 / 42卷 / 03期
关键词
D O I
暂无
中图分类号
学科分类号
摘要
A monitoring piconet, which is made up of the circuit breaker contact monitoring system and the bus temperature monitoring system based on Bluetooth technique, is introduced in this paper. Using the contact-type method of measuring, the equipment temperatures in high potential are converted to wireless signals, which are transmitted to the center monitoring main-controlled computer directly. The systematic hardware circuit construction principle and the software realized methods of PC, SCM and Bluetooth module HCI interface are proposed.
引用
收藏
页码:225 / 227
相关论文
共 50 条
  • [41] Research for the Bearing Grinding Temperature On-Line Monitoring System Based on the Infrared Technology
    Huang Zongxiang
    WMSO: 2008 INTERNATIONAL WORKSHOP ON MODELLING, SIMULATION AND OPTIMIZATION, PROCEEDINGS, 2009, : 129 - 132
  • [42] An on-line content based image monitoring system
    Chen, LY
    Li, SH
    Li, JH
    PROCEEDINGS OF THE 2004 INTERNATIONAL SYMPOSIUM ON INTELLIGENT MULTIMEDIA, VIDEO AND SPEECH PROCESSING, 2004, : 434 - 437
  • [43] On-line monitoring system for insulators based on telemetry
    Cai, Wei
    Li, Min
    Yang, Yan-Hong
    Zhongguo Dianli/Electric Power, 2002, 35 (08):
  • [44] Research for the Bearing Grinding Temperature On-Line Monitoring System Based on the Infrared Technology
    Huang Zongxiang
    FIFTH INTERNATIONAL SYMPOSIUM ON INSTRUMENTATION SCIENCE AND TECHNOLOGY, 2009, 7133
  • [45] Design of On-line Temperature Monitoring System for Power Cable Joints Based on Supercapacitor
    Meng Xianbo
    Hu Xiaoguang
    2012 10TH IEEE INTERNATIONAL CONFERENCE ON INDUSTRIAL INFORMATICS (INDIN), 2012, : 837 - 840
  • [46] On-line measurement of high voltage breaking current for vacuum circuit breaker
    Tsinghua University, Beijing 100084, China
    不详
    Dianli Xitong Zidonghue, 2007, 3 (91-94):
  • [47] On-line hybrid fault diagnosis method for high voltage circuit breaker
    Mei Fei
    Pan Yi
    Zhu Kedong
    Zheng Jianyong
    JOURNAL OF INTELLIGENT & FUZZY SYSTEMS, 2017, 33 (05) : 2763 - 2774
  • [48] Application of the contact potential difference technique for on-line rubbing surface monitoring (review)
    Anatoly L. Zharin
    David A. Rigney
    Tribology Letters, 1998, 4 : 205 - 213
  • [49] Application of the contact potential difference technique for on-line rubbing surface monitoring (review)
    Zharin, Anatoly L.
    Rigney, David A.
    TRIBOLOGY LETTERS, 1998, 4 (02) : 205 - 213
  • [50] Application of a contact potential difference technique for on-line rubbing surface monitoring (review).
    Zharin, A
    Rigney, DA
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1997, 213 : 198 - COLL