Cooling coil design improvement for HVAC energy savings and comfort enhancement

被引:0
作者
机构
[1] Centre for Built Infrastructure Research, School of Electrical, Mechanical and Mechatronic Systems, University of Technology, Sydney
来源
Vakiloroaya, V. (Vahid.vakiloroaya@engineer.com) | 1600年 / Springer Science and Business Media Deutschland GmbH卷 / 22期
关键词
Comfort enhancement; Cooling coil; Design Optimization; Energy Saving;
D O I
10.1007/978-3-642-36645-1_85
中图分类号
学科分类号
摘要
In designing an energy-efficient HVAC system, several factors being to play an important role. Among several others, the performance of cooling coil which is embodied through its configuration, directly influence the performance of HVAC systems and should be considered to be crucial. This paper investigates and recommends design improvements of cooling coil geometry contributes for a central cooling system by using a simulation-optimisation approach. An actual central cooling plant of a commercial building in the hot and dry climate condition is used for experimentation and data collection. An algorithm was created in a transient system simulation program to predict the best design. Available experimental results were compared to predicted results to validate the model. Then different models of several new designs for cooling coil were constructed to evaluate the potential of design improvements. Afterwards, the computer model was used to predict how changes in cooling coil geometry would affect the building environment conditions and the energy consumption of the HVAC components. © Springer-Verlag Berlin Heidelberg 2013.
引用
收藏
页码:965 / 974
页数:9
相关论文
共 50 条
  • [41] Visual comfort and energy savings in classrooms using surveillance camera derived HDR images for lighting and daylighting control system
    Budhiyanto, Aris
    Chiou, Yun-Shang
    JOURNAL OF BUILDING ENGINEERING, 2024, 86
  • [42] Assessing energy savings and visual comfort with PDLC-based smart window in an Istanbul office building: A case study
    Gundogdu, Hasan
    Terkes, Musa
    Demirci, Alpaslan
    Cali, Umit
    ENERGY REPORTS, 2024, 12 : 4252 - 4265
  • [43] Space temperature difference, cooling coil and fan - energy and indoor air quality issues revisited
    Sekhar, SC
    ENERGY AND BUILDINGS, 2005, 37 (01) : 49 - 54
  • [44] INVESTIGATE THE POTENTIAL PEAK ENERGY REDUCTION OF INTEGRATED M-CYCLE EVAPORATIVE COOLING WITH HVAC IN HOT AND DRY CLIMATE
    Almehmadi, Fahad
    Aljabr, Ahmad
    PROCEEDINGS OF THE ASME INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION, 2019, VOL 6, 2019,
  • [45] Improvement of thermal environment and reduction of energy consumption for cooling and heating by retrofitting windows
    Takashi, Mochidome
    Shuichi, Hokoi
    Daisuke, Ogura
    Masahiko, Takamura
    Jun, Suzuki
    FRONTIERS OF ARCHITECTURAL RESEARCH, 2013, 2 (01) : 1 - 10
  • [46] Design of a fuzzy-based control system for energy saving and users comfort
    Martirano, Luigi
    Manganelli, Matteo
    Parise, Luigi
    Sbordone, Danilo A.
    2014 14TH INTERNATIONAL CONFERENCE ON ENVIRONMENT AND ELECTRICAL ENGINEERING (EEEIC), 2014, : 142 - 147
  • [47] The energy-saving design practices for direct cooling refrigerator
    Cai, Y. L.
    Zhang, H.
    Chen, S. H.
    Li, G.
    Xia, P.
    ICEET: 2009 INTERNATIONAL CONFERENCE ON ENERGY AND ENVIRONMENT TECHNOLOGY, VOL 1, PROCEEDINGS, 2009, : 411 - +
  • [48] An investigation on energy savings of a split air-conditioning using different commercial cooling pad thicknesses and climatic conditions
    Harby, K.
    Al-Amri, Fahad
    ENERGY, 2019, 182 : 321 - 336
  • [49] A numerical evaluation of adaptive on-off cooling strategies for energy savings during long-term storage of apples
    Gruyters, W.
    Verboven, P.
    Delele, M.
    Gwanpua, S. G.
    Schenk, A.
    Nicolai, B.
    INTERNATIONAL JOURNAL OF REFRIGERATION, 2018, 85 : 431 - 440
  • [50] Development of approach to optimization of building envelope design in aspect of thermal comfort and energy use
    Hwang, Ruey Lung
    Tsai, Fu Shun
    BUILDING SIMULATION 2007, VOLS 1-3, PROCEEDINGS, 2007, : 206 - +