Facet engineering of Cu2O for efficient electrochemical glucose sensing

被引:1
|
作者
Wei, Chenhuinan [1 ]
Zhang, Yang [1 ]
Wang, Zhuo [1 ]
Hu, Yurun [1 ]
Huang, Jinqi [1 ]
Dai, Bingbing [1 ]
Huang, Le [2 ]
Yu, Ziyang [3 ]
Wang, Huihu [1 ]
机构
[1] Hubei Univ Technol, Sch Mat & Chem Engn, Hubei Prov Key Lab Green Mat Light Ind, Wuhan 430068, Peoples R China
[2] Hubei Univ Technol, Campus Community Hosp, Wuhan 430068, Peoples R China
[3] Wuhan Inst Technol, Sch Opt Informat & Energy Engn, Hubei Key Lab Opt Informat & Pattern Recognit, Wuhan 430205, Peoples R China
关键词
Facet-dependent performance; Cu; 2; O; glucose; Electrochemical sensing; NANOPARTICLES; SENSOR;
D O I
10.1016/j.aca.2024.343525
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Background: Accurate monitoring glucose level is significant for human health management, especially in the prevention, diagnosis, and management of diabetes. Electrochemical quantification of glucose is a convenient and rapid detection method, and the crucial aspect in achieving great sensing performance lies in the selection and design of the electrode material. Among them, Cu2O, with highly catalysis ability, is commonly used as electrocatalyst in non-enzymatic glucose sensing. This feature has attracted great attentions for improving sensing performances by increasing exposed surface area and modifying with other active materials, but the intrinsic electrochemical activity of Cu2O is often diminished. Result: In this work, we synthesized Cu2O cubes with exposed (100) faces, Cu2O octahedron with exposed (111) faces and Cu2O rhombic dodecahedron with exposed (110) faces of similar sizes to investigate the influence of expose facets on its glucose sensing performance. By employing the facets-regulation strategy, the anti- interference performance was largely improved by the Cu2O octahedron when compared with the Cu2O cube and the Cu2O rhombic dodecahedron, while the sensitivity and stability were also improved. Eventually, the Cu2O octahedron with exposed (111) faces based on glucose sensor displayed great practicability in human serum and the relative deviation was less than 3 % when compared with biochemical analyzer. Experimental, calculation and simulation result elucidate that Cu2O octahedron with exposed (111) faces, possessing stronger intrinsic electrochemical activity, comparatively favors the glucose adsorption, electron transfer and current density enhancement, rather than more active sites. Significance and novelty: This work focuses on the exploration of the intrinsic electrochemical activity of Cu2O and confirms that a facets-regulation strategy is an effective approach for boosting performance of non-enzymatic electrochemical sensors, especially for their sensitivity and selectivity. Moreover, it will lay the foundation for advancing the key field of precision medicine.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] In Situ Oxidation of Cu2O Crystal for Electrochemical Detection of Glucose
    Lu, Chenlin
    Li, Zhipeng
    Ren, Liwei
    Su, Nan
    Lu, Diannan
    Liu, Zheng
    SENSORS, 2019, 19 (13):
  • [2] Cu2O and Au/Cu2O Particles: Surface Properties and Applications in Glucose Sensing
    Won, Yu-Ho
    Stanciu, Lia A.
    SENSORS, 2012, 12 (10): : 13019 - 13033
  • [3] Cu/Cu2O/CuO catalyst generated by disproportionation for electrochemical dopamine sensing with improved stability and sensitivity
    Lu, Chengyi
    Ma, Yiyue
    Zhu, Wenxin
    Cao, Yong
    Cao, Yonghui
    Huang, Qiaogao
    Wang, Xuefei
    Wang, Jianlong
    MICROCHEMICAL JOURNAL, 2023, 193
  • [4] Cu2O nanowires with exposed {111} facet for nonenzymatic detection of glucose in complex biological fluids
    Feng, Tao
    Yu, Chaofan
    Kabtamu, Daniel Manaye
    Bu, Le
    Li, Fengting
    Wang, Ying
    CHEMICAL ENGINEERING JOURNAL, 2022, 429
  • [5] Engineering the valence state of ZIF-67 by Cu2O for efficient nonenzymatic glucose detection
    Yang, Nian
    Guo, Kailu
    Zhang, Yanwen
    Xu, Cailing
    JOURNAL OF MATERIALS CHEMISTRY B, 2020, 8 (14) : 2856 - 2861
  • [6] In-situ synthesis of metasequoia-leaf-like Cu/Cu2O/Ni(OH)2 on a glassy carbon electrode for efficient non-enzymatic glucose sensing
    Su, Xiaodong
    Zhang, Yan
    Jia, Zhenfu
    Zhang, Shan
    Gao, Yumeng
    Huang, Yaoyao
    Xu, Chunli
    Liu, Enyu
    MICROCHEMICAL JOURNAL, 2023, 187
  • [7] Enzyme-free amperometric sensing of hydrogen peroxide and glucose at a hierarchical Cu2O modified electrode
    Li, Song
    Zheng, Yajie
    Qin, Gaowu W.
    Ren, Yuping
    Pei, Wenli
    Zuo, Liang
    TALANTA, 2011, 85 (03) : 1260 - 1264
  • [8] Non-enzymatic electrochemical glucose sensing by Cu2O octahedrons: elucidating the protein adsorption signature
    Rakshit, Soumyadipta
    Ghosh, Srabanti
    Roy, Rimi
    Bhattacharya, Subhash Chandra
    NEW JOURNAL OF CHEMISTRY, 2021, 45 (02) : 628 - 637
  • [9] Cu/Cu2O heterojunctions in carbon framework for highly sensitive detection of glucose
    Zhuang, Xiaoli
    Han, Chao
    Zhang, Jingrui
    Sang, Zhaohu
    Meng, Wei
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2021, 882
  • [10] Cu2O Microspheres Supported on Sulfur-Doped Carbon Nanotubes for Glucose Sensing
    Waqas, Muhammad
    Wu, Liyun
    Tang, Huaguo
    Liu, Chengzhou
    Fan, Youjun
    Jiang, Zhe
    Wang, Xiaoqu
    Zhong, Jingping
    Chen, Wei
    ACS APPLIED NANO MATERIALS, 2020, 3 (05) : 4788 - 4798