X-ray coronary angiography background subtraction by adaptive weighted total variation regularized online RPCA

被引:0
作者
Shakeri, Saeid [1 ]
Almasganj, Farshad [1 ]
机构
[1] Amirkabir Univ Technol, Dept Biomed Engn, Tehran, Iran
关键词
background subtraction; coronary vessel extraction; online robust PCA; total variation regularization; x-ray coronary angiography; ENHANCEMENT; ARTERIES; LAYER;
D O I
10.1088/1361-6560/ad8293
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Objective. X-ray coronary angiograms (XCA) are widely used in diagnosing and treating cardiovascular diseases. Various structures with independent motion patterns in the background of XCA images and limitations in the dose of injected contrast agent have resulted in low-contrast XCA images. Background subtraction methods have been developed to enhance the visibility and contrast of coronary vessels in XCA sequences, consequently reducing the requirement for excessive contrast agent injections. Approach. The current study proposes an adaptive weighted total variation regularized online RPCA (WTV-ORPCA) method, which is a low-rank and sparse subspaces decomposition approach to subtract the background of XCA sequences. In the proposed method, the images undergo initial preprocessing using morphological operators to eliminate large-scale background structures and achieve image homogenization. Subsequently, the decomposition algorithm decomposes the preprocessed images into background and foreground subspaces. This step applies an adaptive weighted TV constraint to the foreground subspace to ensure the spatial coherency of the finally extracted coronary vessel images. Main results. To evaluate the effectiveness of the proposed background subtraction method, some qualitative and quantitative experiments are conducted on two clinical and synthetic low-contrast XCA datasets containing videos from 21 patients. The obtained results are compared with six state-of-the-art methods employing three different assessment criteria. By applying the proposed method to the clinical dataset, the mean values of the global contrast-to-noise ratio, local contrast-to-noise ratio, structural similarity index, and reconstruction error (RE) are obtained as 5.976, 3.173, 0.987, and 0.026, respectively. These criteria over the low-contrast synthetic dataset were 4.851, 2.942, 0.958, and 0.034, respectively.
引用
收藏
页数:16
相关论文
共 37 条
  • [1] Coronary artery disease detection using artificial intelligence techniques: A survey of trends, geographical differences and diagnostic features 1991-2020
    Alizadehsani, Roohallah
    Khosravi, Abbas
    Roshanzamir, Mohamad
    Abdar, Moloud
    Sarrafzadegan, Nizal
    Shafie, Davood
    Khozeimeh, Fahime
    Shoeibi, Afshin
    Nahavandi, Saeid
    Panahiazar, Maryam
    Bishara, Andrew
    Beygui, Ramin E.
    Puri, Rishi
    Kapadia, Samir
    Tan, Ru-San
    Acharya, U. Rajendra
    [J]. COMPUTERS IN BIOLOGY AND MEDICINE, 2021, 128
  • [2] Automated three-dimensional vessel reconstruction based on deep segmentation and bi-plane angiographic projections
    Bappy, D. M.
    Hong, Ayoung
    Choi, Eunpyo
    Park, Jong-Oh
    Kim, Chang-Sei
    [J]. COMPUTERIZED MEDICAL IMAGING AND GRAPHICS, 2021, 92
  • [3] Decomposition into low-rank plus additive matrices for background/foreground separation: A review for a comparative evaluation with a large-scale dataset
    Bouwmans, Thierry
    Sobral, Andrews
    Javed, Sajid
    Jung, Soon Ki
    Zahzah, El-Hadi
    [J]. COMPUTER SCIENCE REVIEW, 2017, 23 : 1 - 71
  • [4] Robust Principal Component Analysis?
    Candes, Emmanuel J.
    Li, Xiaodong
    Ma, Yi
    Wright, John
    [J]. JOURNAL OF THE ACM, 2011, 58 (03)
  • [5] Total Variation Regularized RPCA for Irregularly Moving Object Detection Under Dynamic Background
    Cao, Xiaochun
    Yang, Liang
    Guo, Xiaojie
    [J]. IEEE TRANSACTIONS ON CYBERNETICS, 2016, 46 (04) : 1014 - 1027
  • [6] Caselles V., 2015, HDB MATH METHODS IMA, V1, P1455, DOI [10.1007/978-1-4939-0790-823, DOI 10.1007/978-1-4939-0790-823]
  • [7] Minimal Paths for Tubular Structure Segmentation With Coherence Penalty and Adaptive Anisotropy
    Chen, Da
    Zhang, Jiong
    Cohen, Laurent D.
    [J]. IEEE TRANSACTIONS ON IMAGE PROCESSING, 2019, 28 (03) : 1271 - 1284
  • [8] Reconstruction of coronary arteries from X-ray angiography: A review
    Cimen, Serkan
    Gooya, Ali
    Grass, Michael
    Frangi, Alejandro F.
    [J]. MEDICAL IMAGE ANALYSIS, 2016, 32 : 46 - 68
  • [9] Automatic segmentation of coronary arteries using Gabor filters and thresholding based on multiobjective optimization
    Cruz-Aceves, Ivan
    Oloumi, Faraz
    Rangayyan, Rangaraj M.
    Avina-Cervantes, Juan G.
    Hernandez-Aguirre, Arturo
    [J]. BIOMEDICAL SIGNAL PROCESSING AND CONTROL, 2016, 25 : 76 - 85
  • [10] Feng J., 2013, ADV NEURAL INFORM PR, P404