Experimental study of air source heat pump water heater: Energy, exergy, and entransy analysis

被引:2
作者
Ruan F. [1 ]
Xu S. [1 ]
Qin D. [1 ]
Li S. [1 ]
Chen P. [1 ]
机构
[1] College of Civil Engineering, Xiangtan University, Xiangtan
来源
Ruan, Fang (rufa2002@163.com) | 2025年 / 6卷 / 02期
关键词
Air source heat pump water heater; EDR; Entransy dissipation; Exergy analysis; Weather conditions;
D O I
10.1016/j.enbenv.2023.10.006
中图分类号
学科分类号
摘要
With the continuous progress of urbanization, building energy consumption is increasing dramatically. At present, energy consumption caused by air conditioning accounts for a half in typical building energy consumption in China. Using exergy and entransy analysis, this paper experimentally studies the thermal performance of an air source heat pump water heater and its components under different meteorological conditions. This paper, for the first time, introduces the dimensionless number of entransy dissipation ratio (EDR), namely the percentage of a component's entransy dissipation into the entire system. The findings indicate that with the increase in air temperature, the heat production, the EDR of condenser and evaporator, and the exergy efficiency of condenser and compressor increase while the exergic efficiency of evaporator and throttle valve decrease. In the case of increased air flow rate, the heat production and exergy destruction of water heater as well as the EDR of evaporator are enhanced, while the exergy efficiency of evaporator, compressor and throttle and the EDR of condenser decrease, with the exergy efficiency of the throttle remaining the highest. The irreversibility rates of components are affected by change in the relative humidity of air, which is specified as follows: The percentage range of irreversibility rates for compressor, condenser, throttle and evaporator is 11.5–16 %, 37–45 %, 6.8–11.5 % and 32–41 %, respectively. © 2023
引用
收藏
页码:187 / 200
页数:13
相关论文
共 34 条
  • [1] Dincer I., Rosen M.A., Chapter7-exergy analyses of refrigeration and heat pump systems, Energy Environ. Sustain. Dev.., pp. 125-141, (2021)
  • [2] Wang Y., Ye Z., Song Y., Et al., Energy, exergy, economic and environmental analysis of refrigerant charge in air source transcritical carbon dioxide heat pump water heater, Energy Convers. Manag., 223, (2020)
  • [3] Ozturk M.M., Dogan B., Erbay L.B., Performance assessment of an air source heat pump water heater water heater from exergy aspect, Sustain. Energy Technol., 42, (2020)
  • [4] Liang S., Wang H., Gao X., Et al., Experimental study on the operating performance of the air source heat pump (ASHP) with variable outdoor airflow rate under the standard frosting condition, Energy Built Environ, (2020)
  • [5] Kima T., Choia B., Han Y., Et al., A comparative investigation of solar-assisted heat pumps with solar thermal collectors for a hot water supply system, Energy Convers. Manag., 172, pp. 472-484, (2018)
  • [6] Bellos E., Tzivanidis C., Multi-objective optimization of a solar assisted heat pump-driven by hybrid PV, Appl. Therm. Eng., 149, pp. 528-535, (2019)
  • [7] Bai C., Han Z., Wei H., Et al., Simulation study on performance of a dual-source hybrid heat pump unit with alternative refrigerants, Energy Built Environ., 1, pp. 1-10, (2020)
  • [8] Wu J., Xian T., Liu X., All-weather characteristic studies of a direct expansion solar integrated air source heat pump water heater system based on PCMs, Sol. Energy, 191, pp. 34-45, (2019)
  • [9] Qiu G., Wei X., Xua Z., Et al., A novel integrated heating system of solar energy and air source heat pump water heaters and its optimal working condition range in cold regions, Energy Convers. Manag., 174, pp. 922-931, (2018)
  • [10] Simonetti R., Molinaroli L., Manzolini G., Experimental and analytical study of an innovative integrated dual-source evaporator for solar-assisted heat pumps, Sol. Energy, 194, pp. 939-951, (2019)