Implementation mode of tie-line power control performance assessment standard

被引:0
|
作者
Yang, Yongqiang [1 ]
Ba, Yu [1 ]
Wu, Yuqiong [1 ]
Li, Weidong [1 ]
Cheng, Kai [1 ]
Shan, Maohua [2 ]
机构
[1] College of Electrical Engineering, Dalian University of Technology, Dalian,116014, China
[2] China Electric Power Research Institute, Beijing,100192, China
关键词
Electric power system control - Electric power transmission networks;
D O I
10.7500/AEPS20140609007
中图分类号
学科分类号
摘要
This paper firstly analyzes the problems of the implementation modes of standard T. On this basis, the serial implementation mode of control performance standard (CPS) and standard T is put forward according to the thought of solving the main contradiction. The power system switches the CPS and standard T to solve the main contradiction in different operating states of ultra-high voltage (UHV) power grid. At the same time, four control modes are designed in consideration of UHV tie-line power deviation and system frequency deviation. Analyses and simulations have been made to prove that there will be no control contradiction between control areas with consideration of UHV tie-line power deviation and system frequency deviation in the serial implementation mode of CPS and standard T. ©, 2015 State Grid Electric Power Research Institute Press.
引用
收藏
页码:100 / 106
相关论文
共 50 条
  • [1] ADAPTIVE CONTROL OF EXCHANGE POWER ON A TIE-LINE
    PRONOVOS.GA
    CUENOD, M
    GILLE, JC
    AUTOMATISME, 1971, 16 (01): : 3 - &
  • [2] Studies on the tie-line power control with a large scale wind power
    Li Mengyan
    Zhu Tao
    Mi Zengqiang
    Wang Dada
    Chen Zhiyu
    2011 INTERNATIONAL CONFERENCE ON ELECTRONICS, COMMUNICATIONS AND CONTROL (ICECC), 2011, : 2302 - 2305
  • [3] Examination Method for Coordinated Power Control of AC Tie-line
    Liu Z.
    Liu Y.
    Xu H.
    Huang M.
    Yao Z.
    Wang Y.
    Gaodianya Jishu/High Voltage Engineering, 2019, 45 (11): : 3620 - 3626
  • [4] Implementation of tie-line area control error (ACE) examination in East China power grid
    East China Power Dispatching Bur, Shanghai, China
    Dianli Xitong Zidonghue, 14 (51-53):
  • [5] Control of Tie-line Power Flow by Nonlinear SMES Controller
    Wang, Kang
    Lan, Zhou
    Can, Deqiang
    Shi, Libao
    Ni, Yixin
    2008 IEEE POWER & ENERGY SOCIETY GENERAL MEETING, VOLS 1-11, 2008, : 3631 - +
  • [6] Analysis and Control of Stochastic Power Fluctuations on the Tie-line of Interconnected Power Systems
    Zhang, Weiling
    Hu, Wei
    Min, Yong
    Luo, Weihua
    Ge, Weichun
    Wang, Zhiming
    2013 IEEE PES ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), 2013,
  • [7] Visualization of UPFC control parameters effects on the tie-line power flow
    Nabavi-Niaki, SA
    LESCOPE'02: 2002 LARGE ENGINEERINGS SYSTEMS CONFERENCE ON POWER ENGINEERING, CONFERENCE PROCEEDINGS, 2002, : 103 - 107
  • [8] Preliminary design analysis of tie-line bias control of reactive power
    Fuji, S
    Sasaki, T
    Ihara, S
    Pratico, ER
    Price, WW
    2002 IEEE POWER ENGINEERING SOCIETY WINTER MEETING, VOLS 1 AND 2, CONFERENCE PROCEEDINGS, 2002, : 1258 - 1263
  • [9] Control of tie-line power flow by nonlinear robust SMES controller
    Zhejiang University, Hangzhou 310027, China
    不详
    Dianli Xitong Zidonghue, 2008, 8 (5-9+68):
  • [10] TIE-LINE BIAS PRIORITIZED ENERGY CONTROL
    JALEELI, N
    VANSLYCK, LS
    IEEE TRANSACTIONS ON POWER SYSTEMS, 1995, 10 (01) : 51 - 59