Method development of comprehensive two-dimensional liquid chromatography: A new metric for preliminary column selection

被引:1
|
作者
Tirapelle, Monica [1 ]
Duanmu, Fanyi [1 ]
Chia, Dian Ning [1 ]
Besenhard, Maximilian O. [1 ]
Mazzei, Luca [1 ]
Sorensen, Eva [1 ]
机构
[1] UCL, Dept Chem Engn, Torrington Pl, London WC1E 7JE, England
基金
英国工程与自然科学研究理事会;
关键词
Two-dimensional liquid chromatography; In-silico method development; Column orthogonality; Multi-objective optimization; Reversed-phase liquid chromatography; REVERSED-PHASE SEPARATIONS; EFFECTIVE PEAK-CAPACITY; ORTHOGONALITY; SYSTEMS; IMPURITIES; IDENTIFICATION; RESOLUTION; SPACE;
D O I
10.1016/j.chroma.2024.465593
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
To elevate the separation performance, two-dimensional liquid chromatography (2D-LC) uses two chromatographic columns with different stationary phases to diversify solute interactions with the resin, hence providing a second "dimension"to solute-specific separation. Developing methods for 2D-LC starts therefore with preliminary column selection. Selecting columns that yield (metaphorically) orthogonal dimensions is of utmost importance, but remains challenging. Although several metrics exist to quantify column orthogonality, currently there is no established methodology, and none of the existing methods accounts for the non-homogeneity of peak band broadening across each separation dimension. In this work, we propose anew approach to select columns a priori. This approach is based on critical resolution distribution statistics and implicitly accounts for local peak crowding and peak band broadening. Furthermore, we assess the importance of preliminary column selection during in-silico method development and multi-objective optimization of comprehensive 2D-LC. The comparison of the multi-objective Pareto fronts revealed that column pairs selected with our approach provide better separation quality and reduce analysis time compared to column selections via the most established metrics in the literature. Our results prove the importance of preliminary column selection for method development and optimization of 2D-LC systems, and they also show that choosing the right orthogonality metric (such as that proposed here) is crucial.
引用
收藏
页数:12
相关论文
共 50 条
  • [21] Analysis of the temporal performance of one versus on-line comprehensive two-dimensional liquid chromatography
    Potts, Lawrence W.
    Carr, Peter W.
    JOURNAL OF CHROMATOGRAPHY A, 2013, 1310 : 37 - 44
  • [22] Optimizing separations in online comprehensive two-dimensional liquid chromatography
    Pirok, Bob W. J.
    Gargano, Andrea F. G.
    Schoenmakers, Peter J.
    JOURNAL OF SEPARATION SCIENCE, 2018, 41 (01) : 68 - 98
  • [23] Separation of branched polystyrene by comprehensive two-dimensional liquid chromatography
    Im, K
    Kim, Y
    Chang, T
    Lee, K
    Choi, N
    JOURNAL OF CHROMATOGRAPHY A, 2006, 1103 (02) : 235 - 242
  • [24] Bayesian optimization of comprehensive two-dimensional liquid chromatography separations
    Boelrijk, Jim
    Pirok, Bob
    Ensing, Bernd
    Forre, Patrick
    JOURNAL OF CHROMATOGRAPHY A, 2021, 1659
  • [25] The development of an evaluation method for capture columns used in two-dimensional liquid chromatography
    Cao, Liwei
    Yu, Danhua
    Wang, Xinliang
    Ke, Yanxiong
    Jin, Yu
    Liang, Xinmiao
    ANALYTICA CHIMICA ACTA, 2011, 706 (01) : 184 - 190
  • [26] Development of a two-dimensional liquid chromatography system for isolation of drug metabolites
    Jayamanne, Mala
    Granelli, Ingrid
    Tjernberg, Agneta
    Edlund, Per-Olof
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2010, 51 (03) : 649 - 657
  • [27] An improved peak clustering algorithm for comprehensive two-dimensional liquid chromatography data analysis
    Xu, Jucai
    Zheng, Lin
    Su, Guowan
    Sun, Baoguo
    Zhao, Mouming
    JOURNAL OF CHROMATOGRAPHY A, 2019, 1602 : 273 - 283
  • [28] Comprehensive two-dimensional liquid chromatography for the separation of protonated and deuterated polystyrene
    Sinha, Pritish
    Harding, Gareth W.
    Maiko, Khumo
    Hiller, Wolf
    Pasch, Harald
    JOURNAL OF CHROMATOGRAPHY A, 2012, 1265 : 95 - 104
  • [29] Comprehensive two-dimensional liquid chromatography of therapeutic monoclonal antibody digests
    Vanhoenacker, Gerd
    Vandenheede, Isabel
    David, Frank
    Sandra, Pat
    Sandra, Koen
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2015, 407 (01) : 355 - 366
  • [30] Solvent minimization in two-dimensional liquid chromatography
    Horvath, Krisztian
    Sepsey, Annamaria
    Hajos, Peter
    JOURNAL OF CHROMATOGRAPHY A, 2015, 1378 : 32 - 36