Utilizing tuned mass damper for reduction of seismic pounding between two adjacent buildings with different dynamic characteristics

被引:1
作者
Kamgar, Reza [1 ]
Dadkhah, Masoud [2 ]
Heidarzadeh, Heisam [1 ]
Javanmardi, Mahmoud Seidali [1 ]
机构
[1] Shahrekord Univ, Fac Engn, Civil Engn Dept, Shahrekord, Iran
[2] Shahid Bahonar Univ Kerman, Civil Engn Dept, Kerman, Iran
关键词
Tuned mass damper; Pounding force; Concentrated plasticity method; Optimization algorithm; Nonlinear time history analysis; Damage index; INELASTIC STRUCTURES; ENERGY-DISSIPATION; PERFORMANCE; EARTHQUAKE; DAMAGE; MODEL; SEPARATION; VIBRATION; INERTER; DESIGN;
D O I
10.1016/j.soildyn.2024.109036
中图分类号
P5 [地质学];
学科分类号
0709 ; 081803 ;
摘要
Today, population growth and the need for constructing adjacent buildings have raised the likelihood of pounding between adjacent buildings with different dynamic characteristics. The pounding force applied to adjacent buildings during an earthquake is intensive and may cause total or partial damage to structural elements, leading to collapse. It disturbs and complicates the functioning of buildings during and after an earthquake. Therefore, the main aim of this paper is to minimize and, if possible, eliminate the pounding force between two adjacent structures by considering three objective functions. For this aim, the tuned mass damper is utilized here. Also, this paper aims to reduce the number of collisions between different stories of adjacent buildings through a tuned mass damper system. For this purpose, two adjacent steel moment frames with six and ten stories are nonlinearly modeled and validated using the concentrated plasticity model in OpenSees. Moreover, the pounding element is nonlinearly modeled and validated. Then, tuned mass dampers (TMDs) are used on the roofs of the structures. They are optimized in stiffness, mass, and damping coefficient using the grey wolf optimization (GWO) algorithm. Nonlinear time history analysis (NLTHA) is performed under nine far- and near- field earthquakes. The pounding force and structural responses are analyzed, including maximum story acceleration, maximum inter-story drift, and base shear in the TMD-controlled and uncontrolled adjacent buildings. Finally, the Park-Ang damage index is evaluated for the structures with and without the TMD system. It has been found that the maximum pounding force, the maximum acceleration of the stories, the base shear, the drift ratio, and the number of collisions significantly reduce (or omit) in the presence of TMDs when the objective function is considered to be the minimization of the maximum pounding force. It is shown that the maximum pounding force generally declines to zero for this objective function.
引用
收藏
页数:25
相关论文
共 50 条
  • [21] Inerter-Connected Double Tuned Mass Damper for Passive Control of Buildings under Seismic Excitation
    Jalali, Himan Hojat
    Farzam, Maziar Fahimi
    PERIODICA POLYTECHNICA-CIVIL ENGINEERING, 2022, 66 (02): : 421 - 432
  • [22] Effect of the seismic excitation angle on the dynamic response of adjacent buildings during pounding
    Polycarpou, Panayiotis C.
    Papaloizou, Loizos
    Komodromos, Petros
    Charmpis, Dimos C.
    EARTHQUAKES AND STRUCTURES, 2015, 8 (05) : 1127 - 1146
  • [23] Integrated seismic and energetic rehabilitation of existing buildings based on the tuned mass damper concept
    Basili, Michela
    Busato, Filippo
    De Angelis, Maurizio
    RESULTS IN ENGINEERING, 2024, 24
  • [24] Comprehensive Review on Seismic Pounding Between Adjacent Buildings and Available Mitigation Measures
    Elgammal, Ahmed
    Seleemah, Ayman
    Elsharkawy, Mohammed
    Elwardany, Hytham
    ARCHIVES OF COMPUTATIONAL METHODS IN ENGINEERING, 2024, 31 (07) : 4269 - 4304
  • [25] Seismic response control of adjacent high-rise buildings linked by the Tuned Liquid Column Damper-Inerter (TLCDI)
    Wang, Qinhua
    Qiao, Haoshuai
    De Domenico, Dario
    Zhu, Zhiwen
    Tang, Yi
    ENGINEERING STRUCTURES, 2020, 223 (223)
  • [26] Use of inerter devices for weight reduction of tuned mass-dampers for seismic protection of multi-storey buildings: the tuned mass-damper-interter (TMDI)
    Giaralis, Agathoklis
    Marian, Laurentiu
    ACTIVE AND PASSIVE SMART STRUCTURES AND INTEGRATED SYSTEMS 2016, 2016, 9799
  • [27] Seismic retrofitting of academic buildings using roof isolation as a tuned mass damper
    Marulanda, Johannio
    Thomson, Peter
    Tocoche, Julio
    INGENIERIA Y COMPETITIVIDAD, 2023, 25 (01):
  • [28] Structural pounding between adjacent buildings subjected to strong ground motions. Part I: The effect of different structures arrangement
    Efraimiadou, Sofia
    Hatzigeorgiou, George D.
    Beskos, Dimitri E.
    EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 2013, 42 (10) : 1509 - 1528
  • [29] A Bidirectional Pounding Tuned Mass Damper and Its Application to Transmission Tower-Line Systems under Seismic Excitations
    Tian, Li
    Rong, Kunjie
    Bi, Kaiming
    Zhang, Peng
    INTERNATIONAL JOURNAL OF STRUCTURAL STABILITY AND DYNAMICS, 2019, 19 (06)
  • [30] Tuned mass damper asymmetric coupling system for vibration control of adjacent twin buildings
    Ok, Seung-Yong
    ADVANCES IN STRUCTURAL ENGINEERING, 2020, 23 (05) : 954 - 968