Effect of loop diameter on the steady state and stability behaviour of single-phase and two-phase natural circulation loops

被引:41
作者
Vijayan, P.K. [1 ]
Nayak, A.K. [1 ]
Saha, D. [1 ]
Gartia, M.R. [1 ]
机构
[1] Reactor Engineering Division, Bhabha Atomic Research Centre, Trombay
关键词
Natural convection;
D O I
10.1155/2008/672704
中图分类号
学科分类号
摘要
In natural circulation loops, the driving force is usually low as it depends on the riser height which is generally of the order of a few meters. The heat transport capability of natural circulation loops (NCLs) is directly proportional to the flow rate it can generate. With low driving force, the straightforward way to enhance the flow is to reduce the frictional losses. A simple way to do this is to increase the loop diameter which can be easily adopted in pressure tube designs such as the AHWR and the natural circulation boilers employed in fossil-fuelled power plants. Further, the loop diameter also plays an important role on the stability behavior. An extensive experimental and theoretical investigation of the effect of loop diameter on the steady state and stability behavior of single- and two-phase natural circulation loops have been carried out and the results of this study are presented in this paper. Copyright © 2008 P. K. Vijayan et al.
引用
收藏
相关论文
共 40 条
[11]  
Vijayan P.K., Bade M.H., Saha D., Sinha R.K., Venkat Raj V., A generalized flow correlation for single-phase natural circulation loops, Proceedings of the17th National and 6th ISHMT/ASME Heat and Mass Transfer Conference
[12]  
Bau H.H., Torrance K.E., Transient and steady state behaviour of an open, symmetrically heated, free convection loop, International Journal of Heat and Mass Transfer, 24, 4, pp. 597-609, (1981)
[13]  
Ho C.J., Chiou S.P., Hu C.S., Heat transfer characteristics of a rectangular natural circulation loop containing water near its density extreme, International Journal of Heat and Mass Transfer, 40, 15, pp. 3553-3558, (1997)
[14]  
Holman J.P., Boggs J.H., Heat transfer to freon 12 near the critical state in a natural circulation loop, Journal of Heat Transfer, 82, pp. 221-226, (1960)
[15]  
Huang B.J., Zelaya R., Heat transfer behaviour of a rectangular thermosyphon loop, Journal of Heat Transfer, 110, pp. 487-493, (1988)
[16]  
Misale M., Tagliafico L., Tanda G., Experiments in a free convection rectangular loop, Proceedings of the 4th International Symposium on Transport Phenomena in Heat and Mass Transfer, pp. 203-211
[17]  
Nishihara T., Oscillatory instability of a single-phase natural circulation loop, Proceedings of the 8th International Topical Meeting on Nuclear Reactor Thermal-Hydraulics (NURETH '97), pp. 839-847
[18]  
Misale M., Garibaldi P., Passos J.C., De Bitencourt G.G., Experiments in a single-phase natural circulation mini-loop, Experimental Thermal and Fluid Science, 31, 8, pp. 1111-1120, (2007)
[19]  
Mousavian S.K., Misale M., D'Auria F., Salehi M.A., Transient and stability analysis in single-phase natural circulation, Annals of Nuclear Energy, 31, 10, pp. 1177-1198, (2004)
[20]  
Vijayan P.K., Bhojwani V.K., Bade M.H., Investigations on the Effect of Heater and Cooler Orientation on the Steady State, Transient and Stability Behaviour of Single-phase Natural Circulation in A Rectangular Loop, (2001)