Shutdown dose rate calculation for fission reactors: An application of the MS-CADIS method to OPAL

被引:0
|
作者
Marcinkevicius, B. [1 ]
Fedon, C. [1 ]
机构
[1] Nucl Res & consultancy Grp NRG, Westerduinweg 3, NL-1755 ZG Petten, Netherlands
关键词
Fission reactors; Shutdown dose rate; MCNP; ADVANTG; MS-CADIS; FW-CADIS; CODE;
D O I
10.1016/j.pnucene.2024.105448
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
There have been considerable advances of shutdown dose rate (SDDR) calculation methods for fusion related problems, however applications of these methods in the fission reactor field have hitherto been sparse. The present study attempts to bridge this gap by investigating the applicability of SDDR calculation methods for fission reactor problems. Specifically, we aim to assess and validate whether recent advances in SDDR methods can be successfully applied in fission research reactors. To this end, we estimate the shutdown dose rate distribution at the Open Pool Australian Light water reactor (OPAL) using the rigorous two step (R2S) computational method, and we compare the calculated results with the experimental data. This method utilizes a 3D reactor model implemented in the Monte Carlo N-Particle (MCNP) transport code, the AutomeD VAriaNce reduction Generator (ADVANTG) code for geometry discretization and variance reduction calculations, and the Oak Ridge Isotope GENeration (ORIGEN) inventory code for activation calculations. To ensure robustness, we employ two variance reduction techniques, Forward Weighted Consistent Adjoint Driven Importance Sampling (FW-CADIS) and Multi-Step Consistent Adjoint Driven Importance Sampling (MS-CADIS). To the best of our knowledge, this is the first MS-CADIS method implementation for fission reactor problems. The SDDR is estimated at ten locations within the experimental hall, all situated more than 4 m away from the reactor core. The paper shows that, the experimental observations are within the lower and upper bounds of the simulation results for 4 out of 10 locations, while the remaining observations are within a factor of 7, with one significant outlier. The calculated average dose rate is within 5% of the nominal values of the experimental observations for 3 locations. The computational results are within statistical uncertainty by using two different variance reduction techniques, with significant computational advantage of MS-CADIS over FW-CADIS for SDDR calculations. The results indicate that the combination of SDDR distribution maps, estimated dose rate energy dependance, and activation information are powerful tools in identifying the radioisotopes and reactor components dominating the SDDR. These results can contribute to better radiation safety practices in contaminated areas, by enabling the minimal dose path planning or by improving radiation shielding.
引用
收藏
页数:13
相关论文
共 50 条
  • [21] A New Calculation Method for Bode and Nyquist Diagrams of Rotor Startup or Shutdown and Its Application
    Zhang, Xining
    Wu, Jili
    Guo, Jinliang
    Xu, Jinjie
    11TH IEEE INTERNATIONAL CONFERENCE ON CONTROL AND AUTOMATION (ICCA), 2014, : 377 - 382
  • [22] ESTIMATION OF SHUTDOWN DOSE-RATE AROUND RECIRCULATION PIPES DURING OPERATING LIFE OF BOILING WATER-REACTORS
    UCHIDA, S
    ASAKURA, Y
    KITAMURA, M
    MATSUSHIMA, Y
    MEGURO, Y
    OHSUMI, K
    MIKI, M
    JOURNAL OF NUCLEAR SCIENCE AND TECHNOLOGY, 1980, 17 (02) : 119 - 128
  • [23] Verification and validation of the R2Smesh approach for the calculation of high resolution shutdown dose rate distributions
    Majerle, Mitja
    Leichtle, Dieter
    Fischer, Ulrich
    Serikov, Arkady
    FUSION ENGINEERING AND DESIGN, 2012, 87 (5-6) : 443 - 447
  • [24] The use of a Monte Carlo method for uncertainty calculation, with an application to the measurement of neutron ambient dose equivalent rate
    Cox, Maurice
    Harris, Peter
    Nam, Gyeonghee
    Thomas, David
    RADIATION PROTECTION DOSIMETRY, 2006, 121 (01) : 12 - 23
  • [25] Transmutation Approximations for the Application of Hybrid Monte Carlo/Deterministic Neutron Transport to Shutdown Dose Rate Analysis
    Biondo, Elliott D.
    Wilson, Paul P. H.
    NUCLEAR SCIENCE AND ENGINEERING, 2017, 187 (01) : 27 - 48
  • [26] Rigorous MCNP based shutdown dose rate calculations: computational scheme, verification calculations and application to ITER
    Chen, Y
    Fischer, U
    FUSION ENGINEERING AND DESIGN, 2002, 63-64 : 107 - 114
  • [27] Shutdown dose rate assessment with the Advanced D1S method for the European DCLL DEMO
    Palermo, Iole
    Villari, Rosaria
    Ibarra, Angel
    FUSION ENGINEERING AND DESIGN, 2017, 122 : 163 - 175
  • [28] Shutdown dose rate assessment with the Advanced D1S method: Development, applications and validation
    Villari, R.
    Fischer, U.
    Moro, F.
    Pereslavtsev, P.
    Petrizzi, L.
    Podda, S.
    Serikov, A.
    FUSION ENGINEERING AND DESIGN, 2014, 89 (9-10) : 2083 - 2087
  • [29] Implementation and application of PyNE sub-voxel R2S for shutdown dose rate analysis
    张小康
    Patrick C SHRIWISE
    刘松林
    Paul P H WILSON
    Plasma Science and Technology, 2022, (09) : 149 - 155
  • [30] Implementation and application of PyNE sub-voxel R2S for shutdown dose rate analysis
    Zhang, Xiaokang
    Shriwise, Patrick C.
    Liu, Songlin
    Wilson, Paul P. H.
    PLASMA SCIENCE & TECHNOLOGY, 2022, 24 (09)