Shutdown dose rate calculation for fission reactors: An application of the MS-CADIS method to OPAL

被引:0
|
作者
Marcinkevicius, B. [1 ]
Fedon, C. [1 ]
机构
[1] Nucl Res & consultancy Grp NRG, Westerduinweg 3, NL-1755 ZG Petten, Netherlands
关键词
Fission reactors; Shutdown dose rate; MCNP; ADVANTG; MS-CADIS; FW-CADIS; CODE;
D O I
10.1016/j.pnucene.2024.105448
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
There have been considerable advances of shutdown dose rate (SDDR) calculation methods for fusion related problems, however applications of these methods in the fission reactor field have hitherto been sparse. The present study attempts to bridge this gap by investigating the applicability of SDDR calculation methods for fission reactor problems. Specifically, we aim to assess and validate whether recent advances in SDDR methods can be successfully applied in fission research reactors. To this end, we estimate the shutdown dose rate distribution at the Open Pool Australian Light water reactor (OPAL) using the rigorous two step (R2S) computational method, and we compare the calculated results with the experimental data. This method utilizes a 3D reactor model implemented in the Monte Carlo N-Particle (MCNP) transport code, the AutomeD VAriaNce reduction Generator (ADVANTG) code for geometry discretization and variance reduction calculations, and the Oak Ridge Isotope GENeration (ORIGEN) inventory code for activation calculations. To ensure robustness, we employ two variance reduction techniques, Forward Weighted Consistent Adjoint Driven Importance Sampling (FW-CADIS) and Multi-Step Consistent Adjoint Driven Importance Sampling (MS-CADIS). To the best of our knowledge, this is the first MS-CADIS method implementation for fission reactor problems. The SDDR is estimated at ten locations within the experimental hall, all situated more than 4 m away from the reactor core. The paper shows that, the experimental observations are within the lower and upper bounds of the simulation results for 4 out of 10 locations, while the remaining observations are within a factor of 7, with one significant outlier. The calculated average dose rate is within 5% of the nominal values of the experimental observations for 3 locations. The computational results are within statistical uncertainty by using two different variance reduction techniques, with significant computational advantage of MS-CADIS over FW-CADIS for SDDR calculations. The results indicate that the combination of SDDR distribution maps, estimated dose rate energy dependance, and activation information are powerful tools in identifying the radioisotopes and reactor components dominating the SDDR. These results can contribute to better radiation safety practices in contaminated areas, by enabling the minimal dose path planning or by improving radiation shielding.
引用
收藏
页数:13
相关论文
共 50 条
  • [1] Validation of the MS-CADIS Method for Full-Scale Shutdown Dose Rate Analysis
    Wilson, Stephen C.
    Mosher, Scott W.
    Royston, Katherine E.
    Daily, Charles R.
    Ibrahim, Ahmad M.
    FUSION SCIENCE AND TECHNOLOGY, 2018, 74 (04) : 288 - 302
  • [2] SHUTDOWN DOSE RATE ANALYSIS USING THE MULTI-STEP CADIS METHOD
    Ibrahim, Ahmad M.
    Peplow, Douglas E.
    Peterson, Joshua L.
    Grove, Robert E.
    FUSION SCIENCE AND TECHNOLOGY, 2015, 68 (03) : 700 - 704
  • [3] THE MULTI-STEP CADIS METHOD FOR SHUTDOWN DOSE RATE CALCULATIONS AND UNCERTAINTY PROPAGATION
    Ibrahim, Ahmad M.
    Peplow, Douglas E.
    Grove, Robert E.
    Peterson, Joshua L.
    Johnson, Seth R.
    NUCLEAR TECHNOLOGY, 2015, 192 (03) : 286 - 298
  • [4] Shutdown dose rate calculation code system and its application to EAST tokamak
    Wu, Liangliang
    Yang, Qi
    Zou, Jun
    Wang, Guozhong
    He, Tao
    FUSION ENGINEERING AND DESIGN, 2012, 87 (7-8) : 1315 - 1318
  • [5] Development of shutdown dose rate calculation code based on cosRMC and application to benchmark analysis
    Zhang, Xian
    Liu, Shichang
    Lu, Peng
    Zhang, Xiaokang
    Zheng, Yu
    Chen, Yixue
    Liu, Songlin
    FUSION ENGINEERING AND DESIGN, 2021, 173
  • [6] CALCULATION CODE FOR PREDICTING SHUTDOWN DOSE-RATE OF BWR
    MATSUSHIMA, Y
    MEGURO, Y
    UCHIDA, S
    KITAMURA, M
    YUSA, H
    OHSUMI, K
    MIKI, M
    TRANSACTIONS OF THE AMERICAN NUCLEAR SOCIETY, 1979, 32 (JUN): : 759 - 760
  • [7] Shutdown dose rate calculation along the ITER IVVS port
    Flammini, Davide
    Fischer, Ulrich
    Moro, Fabio
    Pampin, Raul
    Puiu, Adrian
    Qiu, Yuefeng
    Reichle, Roger
    Travleev, Anton
    Villari, Rosaria
    FUSION ENGINEERING AND DESIGN, 2018, 136 : 1404 - 1407
  • [8] Benchmark analysis of coupled neutron/decay-gamma transport method NASCA for shutdown dose rate calculation
    Lu, Peng
    Liu, Songlin
    Li, Jia
    Zheng, Yu
    Liu, Shichang
    Qin, Yao
    Chen, Yixue
    Huang, Jianjun
    Yu, Bin
    FUSION ENGINEERING AND DESIGN, 2019, 145 : 54 - 59
  • [9] CALCULATION OF RADIATION FIELD AND SHUTDOWN DOSE RATE FOR FUSION REACTOR BASED ON COSRMC
    Liu, Shichang
    Wang, Zhenyu
    Che, Rui
    PROCEEDINGS OF 2024 31ST INTERNATIONAL CONFERENCE ON NUCLEAR ENGINEERING, VOL 2, ICONE31 2024, 2024,
  • [10] Hybrid Monte Carlo approach for accurate and efficient shutdown dose rate calculation
    Lu, Peng
    Fischer, Ulrich
    Pereslavtsev, Pavel
    Qiu, Yuefeng
    Serikov, Arkady
    Li, Jiangang
    Song, Yuntao
    FUSION ENGINEERING AND DESIGN, 2018, 136 : 498 - 502