首页
学术期刊
论文检测
AIGC检测
热点
更多
数据
Determination of rhenium content in tungsten-rhenium alloys by inductively coupled plasma emission spectrometry
被引:0
作者
:
Xu, Qing
论文数:
0
引用数:
0
h-index:
0
机构:
Guobiao(Beijing)Testing & Certification Co.,Ltd., Beijing,101407, China
Guobiao(Beijing)Testing & Certification Co.,Ltd., Beijing,101407, China
Xu, Qing
[
1
]
Zhang, Xiao
论文数:
0
引用数:
0
h-index:
0
机构:
Guobiao(Beijing)Testing & Certification Co.,Ltd., Beijing,101407, China
Guobiao(Beijing)Testing & Certification Co.,Ltd., Beijing,101407, China
Zhang, Xiao
[
1
]
Hong, Xuejiao
论文数:
0
引用数:
0
h-index:
0
机构:
Guobiao(Beijing)Testing & Certification Co.,Ltd., Beijing,101407, China
Guobiao(Beijing)Testing & Certification Co.,Ltd., Beijing,101407, China
Hong, Xuejiao
[
1
]
Chen, Xiongfei
论文数:
0
引用数:
0
h-index:
0
机构:
Guobiao(Beijing)Testing & Certification Co.,Ltd., Beijing,101407, China
Guobiao(Beijing)Testing & Certification Co.,Ltd., Beijing,101407, China
Chen, Xiongfei
[
1
]
Yu, Xiaohui
论文数:
0
引用数:
0
h-index:
0
机构:
Guobiao(Beijing)Testing & Certification Co.,Ltd., Beijing,101407, China
Guobiao(Beijing)Testing & Certification Co.,Ltd., Beijing,101407, China
Yu, Xiaohui
[
1
]
Xie, Yanyan
论文数:
0
引用数:
0
h-index:
0
机构:
Guobiao(Beijing)Testing & Certification Co.,Ltd., Beijing,101407, China
Guobiao(Beijing)Testing & Certification Co.,Ltd., Beijing,101407, China
Xie, Yanyan
[
1
]
机构
:
[1]
Guobiao(Beijing)Testing & Certification Co.,Ltd., Beijing,101407, China
来源
:
Chinese Journal of Analysis Laboratory
|
2024年
/ 43卷
/ 10期
关键词
:
Atomic emission spectroscopy - Inductively coupled plasma mass spectrometry - Rhenium alloys;
D O I
:
10.13595/j.cnki.issn1000-0720.2023080804
中图分类号
:
学科分类号
:
摘要
:
A method was established for the determination of rhenium content in tungsten-rhenium alloys with mass fraction ranging from 0.50% to 26.00% by inductively coupled plasma emission spectrometry. After dissolving with nitric acid and hydrofluoric acid,the working parameters of the instrument and the experimental conditions were optimized. The precision and accuracy of the method were tested with the tungsten-rhenium alloy samples of WRe0.5,WRe2,WRe5 and WRe25. Eight laboratories were commissioned to carry out collaborative tests. Through statistical analysis,the total average values of the four grades of samples were 0.514%,2.048%, 5.058% and 26.22%,respectively,the relative standard deviations were 0.22%-2.4%,and the recoveries were 97.9%-102.5%. The repeatability limits were 0.023%,0.077%,0.193% and 0.501%,and the reproducibility limits were 0.032%,0.145%,0.235% and 0.623%,respectively. Butanedione oxime spectrophotometry was used for comparison and verification. Both F test and t test showed that the two methods had good consistency. © 2024, Youke Publishing Co.,Ltd. All rights reserved.
引用
收藏
页码:1484 / 1490
相关论文
未找到相关数据
未找到相关数据