Thermal management performance of a novel elliptically grooved flat heat pipe system embedded with internally cooled condenser

被引:0
|
作者
Rakshith, Bairi Levi [1 ,2 ]
Asirvatham, Lazarus Godson [1 ,2 ]
Angeline, Appadurai Anitha [3 ]
Lancy, Bryan [1 ,2 ]
Raj, J. Perinba Selvin [1 ,2 ]
Bose, Jefferson Raja [1 ,2 ]
Wongwises, Somchai [4 ]
机构
[1] Karunya Inst Technol & Sci, Dept Mech Engn, Coimbatore 641114, Tamil Nadu, India
[2] Karunya Inst Technol & Sci, Ctr Res Mat Sci & Thermal Management CRMS &TM, Coimbatore 641114, Tamil Nadu, India
[3] Karunya Inst Technol & Sci, Dept Robot Engn, Coimbatore 641114, Tamil Nadu, India
[4] King Mongkuts Univ Technol Thonburi KMUTT, Fac Engn, Dept Mech Engn, Bangkok 10140, Thailand
关键词
Thermal management; Flat heat pipe; Capillary effect; Groove wick; Electronic cooling; Heat transfer; EVAPORATION;
D O I
10.1016/j.ecmx.2024.100717
中图分类号
O414.1 [热力学];
学科分类号
摘要
Flat heat pipes (FHPs) with rectangular groove wick structures fail to sufficiently uplift the working fluid's liquid meniscus to cover the upper sides of the groove walls due to the vertically flat wall design. This results in the formation of non-evaporative zones, particularly in the evaporator region, leading to elevated wall temperatures at high heat loads. To address this issue, a novel FHP with elliptical grooves as wick is designed and tested across heat loads ranging from 30 to 360 W. Elliptical groove depths of 0.5 mm and 0.7 mm are evaluated and compared to FHPs with rectangular grooves. Results showed that at 360 W, the 0.7 mm depth elliptical grooves resulted in 6.5 % reduction in evaporator wall temperature and 27.8 % reduction in thermal resistance, along with 31.5 % enhancement in effective thermal conductivity compared to rectangular grooves. The curvature of the elliptical grooves, combined with enhanced surface tension effects of the working fluid, efficiently uplifted the liquid meniscus to cover the upper wall of the groove, minimizing non-evaporative zones. Additionally, FHPs with elliptical grooves demonstrated lower entropy generation, indicating higher thermal efficiency. Consequently, FHPs with elliptical groove designs are concluded to be an efficient and suitable solution for the thermal management of miniaturized electronic devices.
引用
收藏
页数:13
相关论文
共 50 条
  • [1] Experimental investigation on the heat transfer performance of flat heat pipe embedded with internally cooled condenser
    Rakshith, Bairi Levi
    Asirvatham, Lazarus Godson
    Angeline, Appadurai Anitha
    Raj, J. Perinba Selvin
    Bose, Jefferson Raja
    Wongwises, Somchai
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2024, 230
  • [2] Thermal performance of a thin flat heat pipe with grooved porous structure
    Zhu, Minghan
    Huang, Jin
    Song, Mengjie
    Hu, Yanxin
    APPLIED THERMAL ENGINEERING, 2020, 173 (173)
  • [3] Cooling of power electronic devices using rectangular flat heat pipes with externally and internally cooled condenser regions
    Rakshith, Bairi Levi
    Asirvatham, Lazarus Godson
    Angeline, Appadurai Anitha
    Raj, Jaya Antony Perinba Selvin
    Bose, Jefferson Raja
    Princess, P. Joyce Beryl
    Gautam, Sneha
    Mahian, Omid
    Ribatski, Gherhardt
    Wongwises, Somchai
    APPLIED THERMAL ENGINEERING, 2024, 236
  • [4] Effect of nanofluids on the thermal performance of a flat micro heat pipe with a rectangular grooved wick
    Do, Kyu Hyung
    Jang, Seok Pil
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2010, 53 (9-10) : 2183 - 2192
  • [5] A novel heat dissipation structure based on flat heat pipe for battery thermal management system
    Wang, Yueqi
    Dan, Dan
    Zhang, Yangjun
    Qian, Yuping
    Panchal, Satyam
    Fowler, Michael
    Li, Weifeng
    Manh-Kien Tran
    Xie, Yi
    INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2022, 46 (11) : 15961 - 15980
  • [6] Thermal performance evaluation of a water-filled axially grooved copper flat heat pipe for electronics cooling
    Jed Mansouri
    Imène Saad
    Samah Maalej
    Améni Driss
    Mohamed Chaker Zaghdoudi
    Journal of Thermal Analysis and Calorimetry, 2022, 147 : 8579 - 8612
  • [7] Thermal performance evaluation of a water-filled axially grooved copper flat heat pipe for electronics cooling
    Mansouri, Jed
    Saad, Imene
    Maalej, Samah
    Driss, Ameni
    Zaghdoudi, Mohamed Chaker
    JOURNAL OF THERMAL ANALYSIS AND CALORIMETRY, 2022, 147 (15) : 8579 - 8612
  • [8] Condenser effects on loop heat pipe system performance - applications to thermal management in next generation vehicles
    Rogers, P
    Ku, J
    Ochterbeck, J
    Nelson, D
    VTMS 6: VEHICLE THERMAL MANAGEMENT SYSTEMS, 2003, : 675 - 684
  • [9] Investigation of the thermal performance of a novel flat heat pipe sink with multiple heat sources
    Han, Xiaoxing
    Wang, Yaxiong
    Liang, Qianqing
    INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 2018, 94 : 71 - 76
  • [10] Passivation and Performance of Inorganic Aqueous Solutions in a Grooved Aluminum Flat Heat Pipe
    Stubblebine, Michael J.
    Catton, Ivan
    JOURNAL OF HEAT TRANSFER-TRANSACTIONS OF THE ASME, 2015, 137 (05):