Evaluating the reliability of solid phase extraction techniques for hydrocarbon analysis by GC-MS

被引:0
|
作者
Srinivasan, Poorna [1 ]
Arguello, Estefania Michelle Endara [1 ]
Atwah, Ibrahim [2 ]
机构
[1] Aramco Amer Houston Res Ctr, 16300 Pk Row Dr, Houston, TX 77084 USA
[2] Saudi Aramco, Dhahran 31311, Saudi Arabia
关键词
Solid phase extraction (SPE); Liquid column chromatography (LCC); Aromatic compounds; Saturate compounds; Thermal maturity; Biomarkers; Gas chromatography-mass spectrometry (GCMS); ORGANIC-COMPOUNDS; AROMATIC-HYDROCARBONS; MOLECULAR-PARAMETERS; MATURITY PARAMETERS; TOARCIAN SHALES; SOURCE ROCKS; PARIS BASIN; SMALL-SCALE; CRUDE OILS; SEPARATION;
D O I
10.1016/j.chroma.2024.465435
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Saturate and aromatic compounds are essential in the petroleum industry for assessing the thermal maturity of source rocks and oils, which is critical for basin modeling and sweet-spot mapping. These compounds also play a role in environmental applications, such as oil spill fingerprinting and biogeochemistry. However, the analysis of these compounds by gas chromatography-mass spectrometry (GC-MS) requires meticulous and time-consuming separation processes. Traditional methods like normal-phase liquid column chromatography (LCC) involve large volumes of harmful solvents. This study evaluates the effectiveness of five different sorbents using solid-phase extraction (SPE) techniques-neutral Si, SiOH, Ag-ion, neutral Al, and Ag-ion mixed with activated silica-compared to LCC. The goal was to discern differences in peak resolution, concentration, and isomer ratios of saturate and aromatic compounds for thermal maturity and source rock assessments. The results show that SiOH, neutral Si, and neutral Al do not fully separate aromatic compounds from the saturate fraction, sometimes leaving 40-100% of aromatics within the saturate fraction. Ag-ion mixed with activated silica provided the best separation, resulting in up to 23 times higher aromatic concentration than SiOH. This method is more reliable for quantifying both saturate and aromatic compounds, increases the efficiency of hydrocarbon evaluations, and reduces solvent consumption by 63%, offering a more sustainable approach to hydrocarbon analysis.
引用
收藏
页数:16
相关论文
共 50 条
  • [1] Solid phase extraction and GC-MS techniques for the confirmation of chlorpyrifos contamination of surface water supplies
    Thompson, TS
    Treble, RG
    BULLETIN OF ENVIRONMENTAL CONTAMINATION AND TOXICOLOGY, 1996, 57 (04) : 525 - 531
  • [2] Solid phase extraction and GC-MS techniques for the confirmation of chlorpyriphos contamination of surface water supplies
    Thompson, T.S.
    Treble, R.G.
    Bulletin of Environmental Contamination and Toxicology, 1996, 57 (04):
  • [3] Development of an interface for directly coupled solid-phase extraction and GC-MS analysis
    Ollers, S
    vanLieshout, M
    Janssen, HG
    Cramers, CA
    LC GC-MAGAZINE OF SEPARATION SCIENCE, 1997, 15 (09): : 846 - &
  • [4] Analysis of Pesticides in Soil Using Dispersive Solid Phase Extraction Coupled to GC-MS
    Tuan Linh Pham
    Tien Hung Phan
    Thanh Dong Nguyen
    SOIL & SEDIMENT CONTAMINATION, 2014, 23 (03): : 339 - 352
  • [5] Analysis of 7 synthetic musks in cream by supported liquid extraction and solid phase extraction followed by GC-MS/MS
    Dong, Haifeng
    Tang, Hua
    Chen, Dazhou
    Xu, Ting
    Li, Lei
    TALANTA, 2014, 120 : 248 - 254
  • [6] Determination of tramadol in hair using solid phase extraction and GC-MS
    Hadidi, KA
    Almasad, JK
    Al-Nsour, T
    Abu-Ragheib, S
    FORENSIC SCIENCE INTERNATIONAL, 2003, 135 (02) : 129 - 136
  • [7] SIMULTANEOUS ANALYSIS OF 50 PESTICIDES IN WATER SAMPLES BY SOLID-PHASE EXTRACTION AND GC-MS
    BENFENATI, E
    TREMOLADA, P
    CHIAPPETTA, L
    FRASSANITO, R
    BASSI, G
    DITORO, N
    FANELLI, R
    STELLA, G
    CHEMOSPHERE, 1990, 21 (12) : 1411 - 1421
  • [8] Determination of Selected Cathinones in Blood by Solid-Phase Extraction and GC-MS
    Antunes, Monica
    Sequeira, Margarida
    Pereira, Mariana de Caires
    Caldeira, Maria Joao
    Santos, Susana
    Franco, Joao
    Barroso, Mario
    Gaspar, Helena
    JOURNAL OF ANALYTICAL TOXICOLOGY, 2021, 45 (03) : 233 - 242
  • [9] Influence of extraction techniques on GC-MS screening results
    Mandic, Dario
    Mandic, Sanja
    Horvat, Vesna
    Majetic-Cetina, Neda
    TOXICOLOGY LETTERS, 2008, 180 : S136 - S136
  • [10] Simultaneous determination of nine APs and BPA in water by solid-phase extraction and GC-MS analysis
    Yin, Hailiang
    Sun, Tao
    Zhou, Tongna
    Liu, Xinliang
    Pan, Yuan
    Wang, Youhe
    Liu, Di
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2023, 51 (07)