Experimental Study on the Performance of an Onboard Hollow-Fiber-Membrane Air Separation Module

被引:0
作者
Tu Y. [1 ]
Zeng Y. [2 ]
机构
[1] School of Mechanical Engineering, Hunan University of Arts and Science, Changde
[2] School of Aeronautic Science and Engineering, Beihang University, Beijing
关键词
Air separation; Aircraft fuel tank inerting; Experimental study; Hollow-fiber-membrane; Onboard air separation device;
D O I
10.32604/FDMP.2022.018423
中图分类号
学科分类号
摘要
Onboard air separation devices, based on hollow fiber membranes, are traditionally used for the optimization of aircraft fuel tank inerting systems. In the present study, a set of tests have been designed and executed to assess the air separation performances of these systems for different air inlet temperatures (70°C∼110°C), inlet pressures (0.1∼0.4 MPa), volume flow rates of nitrogen-enriched air (NEA) (30∼120 L/min) and flight altitudes (1.5∼18 km). In particular, the temperature, pressure, volume flow rate, and oxygen concentration of air, NEA and oxygen-enriched air (OEA) have been measured. The experimental results show that the oxygen concentra-tion of NEA, air separation coefficient, and nitrogen utilization coefficient decrease with the rising of air inlet temperature, air inlet pressure, and flight altitude. The effect of air inlet pressure on the above three parameters is significant, while the influence of air inlet temperature and flight altitude is relatively small. © This work is licensed under a Creative Commons Attribution 4.0 International License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
引用
收藏
页码:355 / 370
页数:15
相关论文
共 50 条
[41]   Experimental study on anti-freezing and thawing performance of reinforced concrete of basalt fiber under corrosion condition [J].
Jin, Sheng-Ji ;
Li, Zhong-Liang ;
Zhang, Jian ;
Wang, Yan-Ling .
Gongcheng Lixue/Engineering Mechanics, 2015, 32 (05) :178-183
[42]   Thermal performance of a V-Corrugated serpentine solar air heater with integrated PCM: A comparative experimental study [J].
Ameri, Mehran ;
Sardari, Reza ;
Farzan, Hadi .
RENEWABLE ENERGY, 2021, 171 :391-400
[43]   Air-cooled photovoltaic roof tile as an example of the BIPVT system - An experimental study on the energy and exergy performance [J].
Wajs, Jan ;
Golabek, Aleksandra ;
Bochniak, Roksana ;
Mikielewicz, Dariusz .
ENERGY, 2020, 197
[44]   Experimental study of the performance of single-band air curtains for a multi-deck refrigerated display cabinet [J].
Chen, YG ;
Yuan, XL .
JOURNAL OF FOOD ENGINEERING, 2005, 69 (03) :261-267
[45]   Experimental study on the performance of a novel fin-tube air heat exchanger with punched longitudinal vortex generator [J].
Wu, J. M. ;
Zhang, H. ;
Yan, C. H. ;
Wang, Y. .
ENERGY CONVERSION AND MANAGEMENT, 2012, 57 :42-48
[46]   Energy performance enhancement of PV system through proposed back cooling techniques and natural air draft: an experimental study [J].
Bedair, Ahmed Osama Mahmoud ;
Shehata, Ahmed S. ;
Hamad, Mostafa S. ;
Tawfik, Adel .
INTERNATIONAL JOURNAL OF GREEN ENERGY, 2025, 22 (08) :1422-1435
[47]   Experimental study on the effect of refrigerant charging amount on the performance of CO2-air source heat pump system [J].
Liu, Zeqin ;
Zhen, Huiran ;
Chang, Yuan ;
Han, Kaiyue ;
Yu, Yongjie ;
Yang, Yang ;
Zhao, Taojie .
INTERNATIONAL CONFERENCE ON OPTOELECTRONIC MATERIALS AND DEVICES (ICOMD 2021), 2022, 12164
[48]   Experimental Study on Performance Comparison Between Heavy and Lightweight Radiant Floor Cooling Combined with Underfloor Ventilation Air Conditioning System [J].
Zhang, Dongliang ;
Cai, Ning ;
Rui, Yingxiang ;
Tang, Hu ;
Liu, Minghui .
PROCEEDINGS OF THE 8TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATION AND AIR CONDITIONING, VOL 2: HVAC&R COMPONENT AND ENERGY SYSTEM, 2014, 262 :475-483
[49]   An experimental study on defrosting performance for an air source heat pump unit at different frosting evenness values with melted frost local drainage [J].
Song, Mengjie ;
Mao, Ning ;
Deng, Shiming ;
Xia, Yudong ;
Chen, Ying .
APPLIED THERMAL ENGINEERING, 2016, 99 :730-740
[50]   An experimental study on defrosting performance of an air source heat pump unit with a multi-circuit outdoor coil at different frosting evenness values [J].
Song, Mengjie ;
Chen, Ailu ;
Mao, Ning .
APPLIED THERMAL ENGINEERING, 2016, 94 :331-340