Control measurement method of range switch for dual GM counter tubes

被引:0
作者
He Z. [1 ]
Xu L. [1 ]
Han L. [1 ]
Guo F. [1 ]
Yang G. [1 ]
Wang W. [1 ]
Zhang L. [1 ]
机构
[1] Wuxi Huapu Microelectronics Co. Ltd., Wuxi
来源
He Jishu/Nuclear Techniques | 2024年 / 47卷 / 02期
关键词
Dual Geiger Miller counter tubes; Overlapping region; Range switch;
D O I
10.11889/j.0253-3219.2024.hjs.47.020402
中图分类号
学科分类号
摘要
[Background] Effective measurement using dual Geiger-Müller (GM) counter tubes hinges on the range switch control technology. This technology facilitates the selection of the appropriate counter tube for measurement. Nonetheless, the performance disparities between the two types of GM counter tubes imply that the conventional method of bifurcating the measurement range into two sections results in reduced linearity for the overlapping measurement ranges. [Purpose] This study aims to propose a new control method for range switching to enhance the linearity of the overlapping ranges in the measurement using dual GM counter tubes. [Methods] A dual GM counter detector was consisted of a low range GM counter tube with measurement range of 0.1 μ Sv· h-1~10 mSv·h-1, and a high range GM counter tube with measurement range of 1 mSv·h-1~100 Sv·h-1. The measurement range of 0.1 μSv·h-1~ 100 Sv·h-1 was segmented into three categories:low, medium, and high. Rapid and automatic transitions between these three ranges were facilitated by high-voltage control circuit, measurement range control circuit and dead time regulation circuit. During the medium range of 1~10 mSv·h-1 measurement, two range switching threshold points were set within the overlapping area, and data from the two GM counters were weighting processed respectively in the single-chip processor, hence appropriate weighting factors that maximize the linear fit of the measurement results of the dual GM counter were obtained. Finally, the 241Am source and 60Co ource were employed to test the dual GM counter detector circuits. [Results] Preliminary test results indicate that the proposed dual GM counter detector facilitates fast automatic transitions among the three measurement ranges, and the linear fit of the counter tube in the overlapping area from 1 000 μGy·h-1 to 10 000 μGy·h-1 is enhanced, making the linear fit of the dual GM counter reach up to 0.999 1 within the measurement range of 251~25 130 μGy·h-1. [Conclusions] The overall measurement linearity of the dual GM counter is effectively improved by proposed control method of this study for range switching. © 2024 Science Press. All rights reserved.
引用
收藏
相关论文
共 16 条
[1]  
XIE Weiping, ZHAO Xihuan, CHEN Hao, Et al., Exploration of quality control methods for monitoring the dose equivalent rate round γ in nuclear power plant, Journal of Radiation Research and Radiation Processing, 40, 4, (2022)
[2]  
YANG Song, ZHANG Xiaoquan, DENG Changming, Et al., Design of portable multi-function radiation detection system, Nuclear Techniques, 45, 11, (2022)
[3]  
YUE Qingyu, WANG Wei, SHENG Peiru, Application of G-M counter in environmental γ radiation continuous monitoring[J], Radialization Protection, 25, 4, pp. 227-230, (2005)
[4]  
Akyurek T, Yousaf M, Liu X, Et al., GM counter deadtime dependence on applied voltage, operating temperature and fatigue[J], Radiation Measurements, 73, pp. 26-35, (2015)
[5]  
SUN Guangzhi, QIU Shunli, XIAO Wei, Et al., Development of a super-high rang γ monitor for high temperature and pressure environment, Nuclear Techniques, 44, 4, (2021)
[6]  
GONG Junjun, SHAO Beibei, XIA Wenming, Et al., Experimental investigation on range extension of GM tube by Time-to-Count method[J], Atomic Energy Science and Technology, 47, 4, pp. 674-678, (2013)
[7]  
LIU Liangjun, WANG Jiangyong, Development of a radicalization monitor based on Time-to-Count technology [J], Nuclear Electronics & Detection Technology, 32, 5, pp. 616-619, (2012)
[8]  
CUI Wei, FANG Dengfu, CHEN Li, Et al., GM tube radiation detector based on time-to-count method, Nuclear Electronics & Detection Technology, 37, 6, pp. 641-646, (2017)
[9]  
Wang P, Tang X B, Gong P, Et al., Design of a portable dose rate detector based on a double Geiger-Mueller counter[J], Nuclear Instruments and Methods in Physics Research Section A:Accelerators, Spectrometers, Detectors and Associated Equipment, 879, pp. 147-152, (2018)
[10]  
ZHAO Jianwei, ZHAO Xinhua, HUANG Xiaofei, Et al., The control technique of range switch for dual G-M counter tubes[J], Nuclear Electronics & Detection Technology, 33, 10, pp. 1263-1265, (2013)