Evaluation of 3D Printed Anthropomorphic Head Phantom for Calibration of TLD in Eye Lens Dosimeter

被引:0
作者
Endarko E. [1 ]
Pitaloka A.W. [1 ]
Inayah A.A. [1 ]
Ramadhan F.R. [1 ]
Kardianto K. [2 ]
Rahayuningsih B. [2 ]
机构
[1] Department of Physics, Institut Teknologi Sepuluh Nopember, Kampus ITS-Sukolilo, East Java, Surabaya
[2] Balai Pengamanan Fasilitas Kesehatan Gubeng, East Java, Surabaya
关键词
Calibration; Dosimetry; Phantom; Radiation; Thermoluminescent Dosimetry;
D O I
10.31661/jbpe.v0i0.2109-1401
中图分类号
学科分类号
摘要
Background: Calibration of Thermo Luminescent Dosimetry (TLD) in eye lens dosimeter requires a standard phantom. The use of anthropomorphic phantoms in calibration needs evaluation. Objective: This study aimed to analyze the angular response of the TLD on the fabricated 3D anthropomorphic head phantom and Computerized Imaging Reference Systems (CIRS)-Computed Tomography (CT) dose phantom as a standard phantom irradiated with Cs-137 and to compare the absorbed dose and linear attenuation for both phantoms. Hp (3) analysis, conversion coefficient (hpK (3)), and calibration factor (CF) are also investigated. Material and Methods: In this experimental study, the fabricated 3D printed anthropomorphic head phantom was analyzed using polylactic acid (PLA) with the skull and then filled with the artificial brain and cerebrospinal fluid (CSF) as a test phantom. TLD-700H and TLD Reader Harshaw 6600 plus were used to analyze the angular response of Cs-137 radiation and to determine the absorbed dose and linear attenuation coefficient of test and standard phantoms. Results: The effect of the angle of radiation source towards TLD reading at the anthropomorphic head phantom has a similar value to the standard phantom with a calibration factor ranging from 0.82 to 1. The absorbed dose measurement and the linear attenuation coefficient of the anthropomorphic head phantom with the standard phantom have different values of 2.52 and 3.78%, respectively. Conclusion: The fabricated 3D printed anthropomorphic head phantom has good potential as an alternative to standard phantoms for TLD calibration in eye lens do-simeter. © 2023, Shiraz University of Medical Sciences. All rights reserved.
引用
收藏
页码:193 / 202
页数:9
相关论文
共 50 条
  • [41] Evaluation of 3D printing materials for fabrication of a novel multi-functional 3D thyroid phantom for medical dosimetry and image quality
    Alssabbagh, Moayyad
    Tajuddin, Abd Aziz
    Abdulmanap, Mahayuddin
    Zainon, Rafidah
    RADIATION PHYSICS AND CHEMISTRY, 2017, 135 : 106 - 112
  • [42] Novel application of 3D printing in brachytherapy using MED610 3D printed insert for I-125 ROPES eye plaque
    Sim, L.
    AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE, 2016, 39 (04) : 863 - 870
  • [43] Calibration and Evaluation of Parameters in A 3D Proximity Rotating Scanner
    Zalud, Ludek
    Kocmanova, Petra
    Burian, Frantisek
    Jilek, Tomas
    Kalvoda, Petr
    Kopecny, Lukas
    ELEKTRONIKA IR ELEKTROTECHNIKA, 2015, 21 (01) : 3 - 12
  • [44] Interactive Visual Calibration of Volumetric Head-Tracked 3D Displays
    Wagemakers, Andrew John
    Fafard, Dylan Brodie
    Stavness, Ian
    PROCEEDINGS OF THE 2017 ACM SIGCHI CONFERENCE ON HUMAN FACTORS IN COMPUTING SYSTEMS (CHI'17), 2017, : 3943 - 3953
  • [45] Development of a semi-anthropomorphic photoacoustic calcaneus phantom based on nano computed tomography and stereolithography 3D printing
    Xu, Zhanpeng
    Locke, Conor S.
    Morris, Richard
    Jamison, DeAndre
    Kozloff, Kenneth M.
    Wang, Xueding
    JOURNAL OF ORTHOPAEDIC RESEARCH, 2024, 42 (03) : 647 - 660
  • [46] Evaluation of radiation detectors for the determination of field output factors in Leksell Gamma Knife dosimetry using 3D printed phantom inserts
    Perrett, Ben
    Seshadri, Venkatakrishnan
    Huxley, Cosmo
    Kumar, Sanjay
    Wawrzak, Michal
    Ramachandran, Prabhakar
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2024, 121
  • [47] Calibration method of the laser beam based on liquid lens for 3D precise measurement
    Miao, Fengjin
    Wu, Bin
    Sun, Zefeng
    Peng, Congcong
    MEASUREMENT, 2021, 178
  • [48] Evaluation of 3D printable rubber-elastomeric polymer as phantom material for Hybrid PET/MRI
    Talalwa, Lotfi
    Gordji-Nejad, Ali
    Natour, Ghaleb
    Drzezga, Alexander
    Bauer, Andreas
    Beer, Simone
    2019 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2019,
  • [49] Evaluation of 3D printing filaments for construction of a pediatric phantom for dosimetry in CBCT
    Fontes Assemany, Ladyjane Pereira
    Rodrigues Junior, Orlando
    da Silva, Ezequiel
    Potiens, Maria da Penha A.
    RADIATION PHYSICS AND CHEMISTRY, 2020, 167
  • [50] 3D evaluation of 3DVH program using BANG3 polymer gel dosimeter
    Watanabe, Yoichi
    Nakaguchi, Yuji
    MEDICAL PHYSICS, 2013, 40 (08)