Evaluation of 3D Printed Anthropomorphic Head Phantom for Calibration of TLD in Eye Lens Dosimeter

被引:0
作者
Endarko E. [1 ]
Pitaloka A.W. [1 ]
Inayah A.A. [1 ]
Ramadhan F.R. [1 ]
Kardianto K. [2 ]
Rahayuningsih B. [2 ]
机构
[1] Department of Physics, Institut Teknologi Sepuluh Nopember, Kampus ITS-Sukolilo, East Java, Surabaya
[2] Balai Pengamanan Fasilitas Kesehatan Gubeng, East Java, Surabaya
关键词
Calibration; Dosimetry; Phantom; Radiation; Thermoluminescent Dosimetry;
D O I
10.31661/jbpe.v0i0.2109-1401
中图分类号
学科分类号
摘要
Background: Calibration of Thermo Luminescent Dosimetry (TLD) in eye lens dosimeter requires a standard phantom. The use of anthropomorphic phantoms in calibration needs evaluation. Objective: This study aimed to analyze the angular response of the TLD on the fabricated 3D anthropomorphic head phantom and Computerized Imaging Reference Systems (CIRS)-Computed Tomography (CT) dose phantom as a standard phantom irradiated with Cs-137 and to compare the absorbed dose and linear attenuation for both phantoms. Hp (3) analysis, conversion coefficient (hpK (3)), and calibration factor (CF) are also investigated. Material and Methods: In this experimental study, the fabricated 3D printed anthropomorphic head phantom was analyzed using polylactic acid (PLA) with the skull and then filled with the artificial brain and cerebrospinal fluid (CSF) as a test phantom. TLD-700H and TLD Reader Harshaw 6600 plus were used to analyze the angular response of Cs-137 radiation and to determine the absorbed dose and linear attenuation coefficient of test and standard phantoms. Results: The effect of the angle of radiation source towards TLD reading at the anthropomorphic head phantom has a similar value to the standard phantom with a calibration factor ranging from 0.82 to 1. The absorbed dose measurement and the linear attenuation coefficient of the anthropomorphic head phantom with the standard phantom have different values of 2.52 and 3.78%, respectively. Conclusion: The fabricated 3D printed anthropomorphic head phantom has good potential as an alternative to standard phantoms for TLD calibration in eye lens do-simeter. © 2023, Shiraz University of Medical Sciences. All rights reserved.
引用
收藏
页码:193 / 202
页数:9
相关论文
共 50 条
  • [31] 3D-printed eye lens dosemeter holder for use in interventional radiology and interventional cardiology
    Mihic, Marija Suric
    Pavelic, Luka
    Kortmis, Maja Vojnic
    Sisko, Jerko
    Maltar-Strmecki, Nadica
    Prlic, Ivica
    RADIATION MEASUREMENTS, 2020, 135
  • [32] Optical fibre based real-time measurements during an LDR prostate brachytherapy implant simulation: using a 3D printed anthropomorphic phantom
    Woulfe, P.
    Sullivan, F. J.
    Byrne, L.
    Doyle, A. J.
    Kam, W.
    Martyn, M.
    O'Keeffe, S.
    SCIENTIFIC REPORTS, 2021, 11 (01)
  • [33] 3D printed dielectric lens for the gain enhancement of a broadband antenna
    Anwar, Muhammad S.
    Abufanas, Hasan
    Bangert, Axel
    INTERNATIONAL JOURNAL OF RF AND MICROWAVE COMPUTER-AIDED ENGINEERING, 2020, 30 (04)
  • [34] An open source heterogeneous 3D printed mouse phantom utilising a novel bone representative thermoplastic
    Price, Gareth
    Biglin, Emma R.
    Collins, Sean
    Aitkinhead, Adam
    Subiel, Anna
    Chadwick, Amy L.
    David, M. Cullen
    Kirkby, Karen J.
    Schettino, Giuseppe
    Tipping, Jill
    Robinson, Andrew
    PHYSICS IN MEDICINE AND BIOLOGY, 2020, 65 (10)
  • [35] Development of a 3D Printed Motion Mechanism for a 4D Respiratory Motion Phantom
    Ahmad, Muhammad Akmal
    Mustaza, Seri Mastura
    Mokri, Siti Salasiah
    Azmi, Nor Aniza
    Ahmad, Rozilawati
    Ramli, Rizauddin
    Rahman, Wan Nordiana Wan Abdul
    Abd Rahni, Ashrani Aizzuddin
    2020 IEEE-EMBS CONFERENCE ON BIOMEDICAL ENGINEERING AND SCIENCES (IECBES 2020): LEADING MODERN HEALTHCARE TECHNOLOGY ENHANCING WELLNESS, 2021, : 132 - 135
  • [36] 3D Gaze Estimation for Head-Mounted Eye Tracking System With Auto-Calibration Method
    Liu, Meng
    Li, Youfu
    Liu, Hai
    IEEE ACCESS, 2020, 8 : 104207 - 104215
  • [37] Small field dosimetry employing the thermoluminescence technique using a 3D printed phantom
    Almeida, S. B.
    Cunha, A. P. V.
    Tavares, P. V. S.
    Sampaio, C. C.
    Menegussi, G.
    Campos, L. L.
    RADIATION PHYSICS AND CHEMISTRY, 2024, 223
  • [38] 3D Printed Calibration Micro-phantoms for Validation of Super-Resolution Ultrasound Imaging
    Ommen, Martin Lind
    Schou, Mikkel
    Beers, Christopher
    Jensen, Jorgen Arendt
    Larsen, Niels Bent
    Thomsen, Erik Vilain
    2019 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2019, : 1212 - 1215
  • [39] 3D printed calibration micro-phantoms for super-resolution ultrasound imaging validation
    Ommen, Martin Lind
    Schou, Mikkel
    Beers, Christopher
    Jensen, Jorgen Arendt
    Larsen, Niels Bent
    Thomsen, Erik Vilain
    ULTRASONICS, 2021, 114
  • [40] Evaluation of 3D printing materials for fabrication of a novel multi-functional 3D thyroid phantom for medical dosimetry and image quality
    Alssabbagh, Moayyad
    Tajuddin, Abd Aziz
    Abdulmanap, Mahayuddin
    Zainon, Rafidah
    RADIATION PHYSICS AND CHEMISTRY, 2017, 135 : 106 - 112