Optimization study on the compact thermal neutron imaging system based on portable D-T neutron generator

被引:0
|
作者
Yu, Zihong [1 ]
Zhang, Yan [1 ,2 ]
Zhang, Haoran [1 ]
Liu, Chi [1 ]
Fang, Yuanyang [1 ]
Wang, Renbo [1 ]
Tang, Bin [1 ,2 ]
机构
[1] East China Univ Technol, Natl Key Lab Uranium Resources Explorat Min & Nucl, Nanchang 330013, Peoples R China
[2] East China Univ Technol, Engn Res Ctr Nucl Technol Applicat, Minist Educ, Nanchang 330013, Peoples R China
基金
中国国家自然科学基金;
关键词
Thermal neutron imaging; Monte Carlo simulation; D -T neutron generator; Collimator; GRAPHITE-ELECTRODES; RADIOGRAPHY; DESIGN;
D O I
10.1016/j.nima.2024.170018
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The distribution of lithium in lithium-ion batteries is critical to their performance and lifespan. Studies have shown that thermal neutron imaging can effectively perform non-destructive testing of this distribution. However, most current thermal neutron imaging systems rely on expensive, bulky, and immobile nuclear reactors or spallation neutron sources, significantly limiting their application scenarios. Therefore, this study adopts a portable D-T neutron generator as the neutron source and uses Monte Carlo simulation methods to optimize the design of key components in the thermal neutron imaging system. Simulation results indicate that the optimized thermal neutron imaging system achieves a thermal neutron flux of 8.36 x 104 n.cm(-2).s(-1) and a thermal neutron content (TNC) of 14.4% at a collimation ratio of 50. Within an imaging range of Phi 100 mm, the non-uniformity of the thermal neutron fluence is approximately 2.07%. Simulation imaging results of lithium and iron step wedges demonstrate that the compact thermal neutron imaging system designed in this study can effectively distinguish between iron and lithium of the same thickness. This finding provides an important reference for subsequent detection of lithium distribution within lithium-ion batteries.
引用
收藏
页数:9
相关论文
共 50 条
  • [21] Monte Carlo simulation of moderator and reflector in coal analyzer based on a D-T neutron generator
    Shan, Qing
    Chu, Shengnan
    Jia, Wenbao
    APPLIED RADIATION AND ISOTOPES, 2015, 105 : 204 - 208
  • [22] Monte Carlo simulation on n-γ density logging using D-T neutron generator
    Yao, Z. (zeyao@lzu.edu.cn), 1600, Editorial Office of High Power Laser and Particle Beams, P.O. Box 919-805, Mianyang, 621900, China (25): : 253 - 258
  • [23] A Novel NDT Scanning System Based on Line Array Fast Neutron Detector and D-T Neutron Source
    Wang, Sheng
    Cao, Chao
    Yin, Wei
    Wu, Yang
    Huo, Heyong
    Sun, Yong
    Liu, Bin
    Yang, Xin
    Li, Rundong
    Zhu, Shilei
    Wu, Chunlei
    Li, Hang
    Tang, Bin
    MATERIALS, 2022, 15 (14)
  • [24] Feasibility of sealed D-T neutron generator as neutron source for liver BNCT and its beam shaping assembly
    Liu, Zheng
    Li, Gang
    Liu, Linmao
    APPLIED RADIATION AND ISOTOPES, 2014, 86 : 1 - 6
  • [25] Design and dosimetric evaluation of beam shaping assembly for BNCT of compact D-T neutron generator by Monte Carlo simulation
    Sahoo, G. S.
    Sharma, S. D.
    Tripathy, S. P.
    Bandyopadhyay, T.
    BIOMEDICAL PHYSICS & ENGINEERING EXPRESS, 2018, 4 (01):
  • [26] Moderation device design for detecting hidden highly enriched uranium based on D-T neutron generator
    Jiang, Shang-Rui
    Shi, Guang-Yu
    Chen, Si -Yuan
    Jing, Shi-Wei
    Liu, Chao
    ANNALS OF NUCLEAR ENERGY, 2023, 183
  • [27] A novel design of beam shaping assembly to use D-T neutron generator for BNCT
    Kasesaz, Yaser
    Karimi, Marjan
    APPLIED RADIATION AND ISOTOPES, 2016, 118 : 317 - 325
  • [28] Design of a PGNAA facility using D-T neutron generator for bulk samples analysis
    Cheng, Can
    Wei, Zhiyong
    hei, Daqian
    Jia, Wenbao
    Sun, Aiyun
    Li, Jiatong
    Cai, Pingkun
    Zhao, Dong
    Shan, Qing
    Ling, Yongsheng
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2019, 452 : 30 - 35
  • [29] Design, testing and optimization of a neutron radiography system based on a Deuterium-Deuterium (D-D) neutron generator
    Bergaoui, K.
    Reguigui, N.
    Gary, C. K.
    Cremer, J. T.
    Vainionpaa, J. H.
    Piestrup, M. A.
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2014, 299 (01) : 41 - 51
  • [30] Design and optimization of a beam shaping assembly for BNCT based on D-T neutron generator and dose evaluation using a simulated head phantom
    Rasouli, Fatemeh S.
    Masoudi, S. Farhad