Monte Carlo simulation analysis of X-ray density logging shields

被引:0
作者
Liu, Rui [1 ,2 ]
Yu, Huawei [1 ,2 ]
Zhu, Qian [1 ,2 ]
Yue, Aizhong [3 ]
Wang, Hu [3 ]
Liu, Chaozhuo [4 ]
Zhang, Qianwen [1 ,2 ]
Yang, Shu [1 ,2 ]
Zhu, Linke [1 ,2 ]
Zhang, Xiaolei [3 ]
机构
[1] National Key Laboratory of Deep Oil and Gas, China University of Petroleum (East China), Qingdao
[2] School of Geosciences, China University of Petroleum (East China), Qingdao
[3] Well Logging Technology Research Institute of China Petroleum Group Well Logging Co., Ltd., Xi'an
[4] School of Science, China University of Petroleum (East China), Qingdao
来源
He Jishu/Nuclear Techniques | 2024年 / 47卷 / 08期
关键词
Controllable source; Density logging; Monte Carlo simulation; Shield; X-ray;
D O I
10.11889/j.0253-3219.2024.hjs.47.080202
中图分类号
学科分类号
摘要
[Background] The use of controlled X-ray sources instead of 137Cs radioactive sources in density logging has become a new trend. The intensity of the X-ray source is substantially influenced by the high voltage on the target substrate, and the density measurement uncertainty can be maintained at 0.01 g·cm−3 when the high voltage is 350 kV. [Purpose] This study aims to analyze the parameters of the shielding material and thickness suitable for the 350 kV high-voltage X-ray density logging instrument. [Methods] The Monte Carlo method was used to analyze the energy spectrum and counting rate of X-rays passing through different materials and thicknesses. By comparing the correlation between the 0~0.15 MeV and 0.15~0.35 MeV energy windows, the reasons for the difference between the X-ray attenuation and detector count rate in different energy windows were determined. In addition, combined with the actual instrument model construction of the four-detector X-ray density logging instrument, the influence of the three parts of particles on the detector was primarily considered. The placement mode and optimal thickness of each part of the shield for detectors were analyzed and designed using Monte Carlo N-particle (MCNP) simulation. [Results] The simulation results show that the attenuation of X-rays in high- and low-energy windows increases with increase of atomic number and thickness of shielding materials. When tungsten nickel iron alloy is selected as the shielding material for the four-detector X-ray density logging instrument model, the suitable thickness of the shield between the base and the near-source detector is 1.75 cm. Meanwhile, to maintain the high voltage of X-ray generator at 350 kV, a shield layer with a thickness of 0.2 cm is placed between each detector, and a shield layer with a thickness of 0.35 cm is added to the back of the detector. [Conclusions] This study provides the design theory and key parameters for shielding materials and structures in the development of X-ray density logging tool. © 2024 Science Press. All rights reserved.
引用
收藏
相关论文
共 15 条
  • [1] Yu H W, Wang Z, Xue Z B, Et al., Corrections of fast neutron inelastic scattering effects on D-T neutron porosity logging, Applied Radiation and Isotopes, 190, (2022)
  • [2] Becker A J, Boyce J R, Corris G W, Et al., Detection of scattered X-rays from an electron linac in a borehole[J], Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms, pp. 995-998, (1987)
  • [3] ZHANG Feng, LI Yafen, XIN Yi, Et al., Numerical simulation of density logging based on X-ray and gamma ray sources[J], Journal of China University of Petroleum (Edition of Natural Science), 42, 1, pp. 60-66, (2018)
  • [4] Simon M, Tkabladze A, Beekman S, Et al., A revolutionary X-ray tool for true sourceless density logging with superior performance, SPWLA 59th Annual Logging Symposium, (2018)
  • [5] CHEN Xu, WEI Cunfeng, SUN Jinchuan, Et al., Simulation analysis and experimental verification on the X-ray protective properties of tungsten alloy, Chinese Journal of Stereology and Image Analysis, 24, 1, pp. 9-15, (2019)
  • [6] Bayless J R, Burkhart C P, Kuthi A., Advances in X-ray and neutron source technologies for logging applications, SPWLA Annual Logging Symposium, (1993)
  • [7] HONG Youmi, Logging principle and comprehensive interpretation, (1998)
  • [8] YU Huawei, YANG Zhengchun, LIU Chaozhuo, Et al., Effects of X-ray tube high-voltages on the density measurement accuracy in X-ray density logging, Nuclear Techniques, 44, 11, (2021)
  • [9] WANG Hu, LIU Rui, YUE Aizhong, Et al., Depth-of-investigation characteristics and influence of 350-kV high-voltage X-ray density logging, Nuclear Techniques, 46, 10, (2023)
  • [10] CHEN Xianghong, Basic research on X-ray density logging method, (2020)