A Study on the Mechanical Behavior of a Wind Turbine Foundation with a Constrained Structural Shear Connector

被引:0
作者
Qi, Jingjing [1 ]
Ye, Yining [1 ]
Jiang, Lizhong [1 ]
Lue, Weirong [1 ]
Lu, Beirong [1 ]
Wu, Jidong [1 ]
机构
[1] Hunan Univ Sci & Technol, Sch Civil Engn, Xiangtan 411201, Peoples R China
关键词
wind turbine; shear connector; shear strength; composite structure; interface shear; embedding stiffness;
D O I
10.3390/buildings14103162
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Aiming to solve the problems that a wind turbine foundation with a foundation pipe may suffer from grouting, where the concrete around the interface collapses and the interface disintegrates under a long-term wind load, a kind of wind turbine foundation with a constrained structural shear connector is proposed. In this article, the scaling model tests and a finite element simulation of a traditional stud foundation pipe, perforated steel shear connector foundation pipe, and three groups of constrained structural shear connector foundation pipes with different anchored depths are presented. The force transmission mechanism and damage mechanism of constrained structural shear connector wind turbine foundations are revealed, and the shear resistance of a constrained structural shear connector is analyzed. The influences of buried depth and other parameters on the mechanical properties of the shear connector are also investigated. The results show that the constrained structural shear connector has the advantages of stronger interfacial stiffness and significant force transfer and diffusion, and can more effectively connect the foundation pipe and concrete foundation to work together. It can give full play to the material advantages of concrete and reinforcements, and effectively improve the embedded stiffness and durability of concrete foundations. It can solve the problem of cracks in concrete caused by local pressure. At the same time, it is suggested that the diameter of the surrounding concrete should be in the range of 3 to 4 D, and the embedment depth of the stud should not be less than 0.4 D to give full play to the performance of the constrained structural shear connector.
引用
收藏
页数:22
相关论文
共 19 条
  • [1] Chen P., 2019, Ph.D. Thesis, DOI [10.27738/d.cnki.ghnkd.2019.000655, DOI 10.27738/D.CNKI.GHNKD.2019.000655]
  • [2] Jia B.X., 2021, Ph.D. Thesis., DOI [10.27809/d.cnki.gsjgc.2021.000265, DOI 10.27809/D.CNKI.GSJGC.2021.000265]
  • [3] [李进平 Li Jinping], 2021, [华中科技大学学报. 自然科学版, Journal of Huazhong University of Science and Technology. Nature Science], V49, P107
  • [4] Liang H.J., 2021, Sci. Technol. Eng., V21, P2889
  • [5] Liu J.L., 2020, Ph.D. Thesis, DOI [10.27415/d.cnki.gxngc.2020.000567, DOI 10.27415/D.CNKI.GXNGC.2020.000567]
  • [6] Liu L., 2021, Build. Struct, V37, P1031, DOI [10.19701/j.jzjg.23S1625, DOI 10.19701/J.JZJG.23S1625]
  • [7] [刘哲锋 Liu Zhefeng], 2021, [可再生能源, Renesable Energy Resources], V39, P1483
  • [8] Lu B.R., 2017, Mechanism, Detection, Design and Reinforcement of Wind-Induced Fatigue Damage of Fan Foundation
  • [9] [吕伟荣 Lu Weirong], 2018, [工程力学, Engineering Mechanics], V35, P127
  • [10] [陆征然 Lu Zhengran], 2021, [沈阳建筑大学学报. 自然科学版, Journal of Shenyang Jianzhu University. Natural Science], V37, P1031