摘要
Loop heat pipes (LHP) have great application prospects in the cooling of electronic elements duo to their compactness and high efficiency. This paper designed a compact LHP with capillary core flat-over evaporator and investigated its start-up and heat transfer performance under various conditions experimentally. The results show that a higher heating power and higher refrigerant charge are beneficial with the LHP starts up stably, while it happens oscillation during the start-up process with low heat load and charge ratio. As for the heat transfer performance, there is an optimal refrigerant filling ratio corresponding to the heat load where the LHP shows the best cooling performance. The optimal filling ratio is small when the heat load is relatively low, and the performance will be better if the refrigerant charge is relatively large under a condition with high heat load. © 2021, Editorial Board of CIESC Journal. All right reserved.
引用
收藏
页码:3288 / 3295
页数:7
相关论文
共 32 条
  • [11] Lv L, Li J., Managing high heat flux up to 500 W/cm<sup>2</sup> through an ultra-thin flat heat pipe with superhydrophilic wick, Applied Thermal Engineering, 122, pp. 593-600, (2017)
  • [12] Su D S, Tang Y, Tang B, Et al., Reseach on capillary pumped loop with screen mesh capillary wick, Fluid Machinery, 36, 7, pp. 9-12, (2008)
  • [13] Dong L, Xu W Q, Li Q Q., Experiment and simulation analysis of special-shaped overall heat pipe radiator, CIESC Journal, 67, 10, pp. 4104-4110, (2016)
  • [14] Kempers R, Ewing D, Ching C Y., Effect of number of mesh layers and fluid loading on the performance of screen mesh wicked heat pipes, Applied Thermal Engineering, 26, 5, pp. 589-595, (2006)
  • [15] Zhu M H, Bai P F, Hu Y X, Et al., Heat transfer performance of ultra-thin plate heat pipe with sintered porous channels structures wick, CIESC Journal, 70, 4, pp. 1349-1357, (2019)
  • [16] Liu J Y, Luan T, Liu L F, Et al., Comparative study of surface modified carbon fiber capillary wicks in loop heat pipe, Surface Technology, 48, 1, pp. 175-181, (2019)
  • [17] Xiang J H, Zhang C L, Jiang F., Fabrication technology of miniaturized loop heat pipe, Advanced Materials Research, 426, pp. 227-230, (2012)
  • [18] Liu L F., Study and optimization of flat lood heat pipe with carbon fiber capillary wicks, (2019)
  • [19] Liu Z C, Liu W, Nakayama A., Flow and heat transfer analysis in porous wick of CPL evaporator based on field synergy principle, Heat and Mass Transfer, 43, 12, pp. 1273-1281, (2007)
  • [20] Singh R, Akbarzadeh A, Dixon C, Et al., Theoretical modelling of miniature loop heat pipe, Heat and Mass Transfer, 46, 2, pp. 209-224, (2009)