Evaluation of the Working Mechanism of a Newly Developed Powered Ankle-Foot Orthosis

被引:0
|
作者
Everaert, Laure [1 ]
Sevit, Roy [2 ]
Dewit, Tijl [1 ,3 ]
Janssens, Koen [2 ]
Vanloocke, Jolien [1 ]
Van Campenhout, Anja [4 ,5 ]
Labey, Luc [6 ]
Muraru, Luiza [2 ]
Desloovere, Kaat [1 ,2 ]
机构
[1] Katholieke Univ Leuven, Fac Movement & Rehabil Sci, Dept Rehabil Sci, B-3001 Leuven, Belgium
[2] Thomas More Univ Appl Sci, Ctr Expertise Care & Well Being, Res Grp Mobilab & Care, Campus Geel, B-2440 Geel, Belgium
[3] Univ Hosp Leuven, Clin Mot Anal Lab, B-3000 Leuven, Belgium
[4] Katholieke Univ Leuven, Dept Dev & Regenerat, Fac Med, B-3001 Leuven, Belgium
[5] Univ Hosp Leuven, Dept Orthoped, Pediat Orthoped, B-3001 Leuven, Belgium
[6] Katholieke Univ Leuven, Fac Engn Technol, Dept Mech Engn, B-3001 Leuven, Belgium
关键词
cerebral palsy; ankle-foot orthosis; exoskeleton; biomechanics; gait; CEREBRAL-PALSY; CHILDREN; WALKING; GAIT; EXOSKELETON;
D O I
10.3390/s24206562
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Ankle-foot orthoses (AFOs) are commonly prescribed to children with cerebral palsy (CP). The conventional AFO successfully controls the first and second ankle rocker, but it fails to correct the third ankle rocker, which negatively effects push-off power. The current study evaluated a new powered AFO (PAFO) design, developed to address the shortcomings of the conventional AFO. Eight children with spastic CP (12.4 +/- 3.4 years; GMFCS I-III; 4/4-male/female; 3/5-bi/unilateral) were included. Sagittal kinematic and kinetic data were collected from 20 steps during barefoot walking, with conventional AFOs and PAFOs. In the PAFO-condition, an actuation unit was attached to a hinged AFO and through push-pull cables to a backpack that was carried by the child and provided patient-specific assistance-as-needed. SnPM-analysis indicated gait cycle sections that differed significantly between conditions. For the total group, differences between the three conditions were found in ankle kinematics (49.6-66.1%, p = 0.006; 88.0-100%, p = 0.011) and angular velocity (0.0-6.0%, p = 0.001; 45.1-51.1%, p = 0.006; 62.2-73.0%, p = 0.001; 81.2-93.0%, p = 0.001). Individual SnPM-analysis revealed a greater number of significant gait cycle sections for kinematics and kinetics of the ankle, knee, and hip. These individual results were heterogeneous and specific per gait pattern. In conclusion, the new PAFO improved the ankle range-of-motion, angular velocity, and power during push-off in comparison to the conventional AFO.
引用
收藏
页数:15
相关论文
共 50 条
  • [21] The Kinetic and Kinematic Efficacy of Posterior Leaf Spring Ankle-foot Orthosis in Patients with Drop foot
    Rahbar, Soulmaz
    Pourhoseingholi, Ensieh
    Hoseini, Parinaz
    Asgharian, Seyedeh Fatemeh
    Nouri, Mohamad Javad
    Mohamadi, Somayeh
    Piri, Mohamed Mahdi
    CURRENT ORTHOPAEDIC PRACTICE, 2025, 36 (01):
  • [22] Design and evaluation of a modularized ankle-foot orthosis with quick release mechanism
    Li, Wentao
    Lemaire, Edward D.
    Baddour, Natalie
    42ND ANNUAL INTERNATIONAL CONFERENCES OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY: ENABLING INNOVATIVE TECHNOLOGIES FOR GLOBAL HEALTHCARE EMBC'20, 2020, : 4831 - 4834
  • [23] Towards an ankle-foot orthosis powered by a dielectric elastomer actuator
    Allen, David P.
    Little, Ryan
    Laube, Joshua
    Warren, Jeremy
    Voit, Walter
    Gregg, Robert D.
    MECHATRONICS, 2021, 76
  • [24] Ankle-foot orthosis bending axis influences running mechanics
    Esposito, Elizabeth Russell
    Ranz, Ellyn C.
    Schmidtbauer, Kelly A.
    Neptune, Richard R.
    Wilken, Jason M.
    GAIT & POSTURE, 2017, 56 : 147 - 152
  • [25] Commonly Used Types and Recent Development of Ankle-Foot Orthosis: A Narrative Review
    Choo, Yoo Jin
    Chang, Min Cheol
    HEALTHCARE, 2021, 9 (08)
  • [26] Design and characterization of a variable-stiffness ankle-foot orthosis
    Rong, Haochen
    Ramezani, Sepehr
    Ambro, Alex
    Lei, Chi Hou
    Choi, Hwan
    PROSTHETICS AND ORTHOTICS INTERNATIONAL, 2024, 48 (06) : 720 - 726
  • [27] Ankle-foot orthosis with an oil damper versus nonarticulated ankle-foot orthosis in the gait of patients with subacute stroke: a randomized controlled trial
    Yamamoto, Sumiko
    Motojima, Naoyuki
    Kobayashi, Yosuke
    Osada, Yuji
    Tanaka, Souji
    Daryabor, Aliyeh
    JOURNAL OF NEUROENGINEERING AND REHABILITATION, 2022, 19 (01)
  • [28] Evaluation of a Powered Ankle-Foot Prosthetic System During Walking
    Ferris, Abbie E.
    Aldridge, Jennifer M.
    Rabago, Christopher A.
    Wilken, Jason M.
    ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 2012, 93 (11): : 1911 - 1918
  • [29] Preliminary Design and Engineering Evaluation of a Hydraulic Ankle-Foot Orthosis
    Neubauer, Brett
    Durfee, William
    JOURNAL OF MEDICAL DEVICES-TRANSACTIONS OF THE ASME, 2016, 10 (04): : 1 - 9
  • [30] Estimating System State During Human Walking With a Powered Ankle-Foot Orthosis
    Li, David Yifan
    Becker, Aaron
    Shorter, Kenneth Alex
    Bretl, Timothy
    Hsiao-Wecksler, Elizabeth T.
    IEEE-ASME TRANSACTIONS ON MECHATRONICS, 2011, 16 (05) : 835 - 844