Monitoring Escherichia coli in Water through Real-Time Loop-Mediated Isothermal Amplification on Biochips

被引:2
作者
Wang, Yuxin [1 ,2 ,3 ]
Chan, Yun-Sheng [1 ,4 ]
Lee, Eugene [4 ]
Shi, Donglu [2 ,5 ]
Lee, Chen-Yi [4 ]
Diao, Jiajie [1 ,3 ]
机构
[1] Univ Cincinnati, Coll Med, Dept Canc Biol, Cincinnati, OH 45267 USA
[2] Univ Cincinnati, Coll Engn & Appl Sci, Dept Mech & Mat Engn, Mat Sci & Engn Program, Cincinnati, OH 45221 USA
[3] Univ Cincinnati, Adv Sensing Lab, Digital Futures, Cincinnati, OH 45221 USA
[4] Natl Yang Ming Chiao Tung Univ, Inst Elect, Hsinchu 30010, Taiwan
[5] Univ Cincinnati, Coll Engn & Appl Sci, Dept Biomed Engn, Cincinnati, OH 45221 USA
关键词
water quality monitoring; digital microfluidic biochip (DMFB); micro-electrode dot array (MEDA); programmable biochip; loop-mediated isothermal amplification (LAMP); Escherichia coli; DISEASE; QUALITY; BURDEN; COST;
D O I
10.3390/mi15091112
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Access to clean water is fundamental to public health and safety, serving as the cornerstone of well-being in communities. Despite the significant investments of millions of dollars in water testing and treatment processes, the United States continues to grapple with over 7 million waterborne-related cases annually. This persistent challenge underscores the pressing need for the development of a new, efficient, rapid, low-cost, and reliable method for ensuring water quality. The urgency of this endeavor cannot be overstated, as it holds the potential to safeguard countless lives and mitigate the pervasive risks associated with contaminated water sources. In this study, we introduce a biochip LAMP assay tailored for water source monitoring. Our method swiftly detects even extremely low concentrations of Escherichia coli (E. coli) in water, and 10 copies/mu L of E. coli aqueous solution could yield positive results within 15 min on a PC-MEDA biochip. This innovation marks a significant departure from the current reliance on lab-dependent methods, which typically necessitate several days for bacterial culture and colony counting. Our multifunctional biochip system not only enables the real-time LAMP testing of crude E. coli samples but also holds promise for future modifications to facilitate on-site usage, thereby revolutionizing water quality assessment and ensuring rapid responses to potential contamination events.
引用
收藏
页数:10
相关论文
共 19 条
[1]   Trends in infectious disease mortality in the United States during the 20th century [J].
Armstrong, GL ;
Conn, LA ;
Pinner, RW .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1999, 281 (01) :61-66
[2]  
BERGE B, 1993, CR ACAD SCI II, V317, P157
[3]   Rapid Molecular Detection of Tuberculosis and Rifampin Resistance [J].
Boehme, Catharina C. ;
Nabeta, Pamela ;
Hillemann, Doris ;
Nicol, Mark P. ;
Shenai, Shubhada ;
Krapp, Fiorella ;
Allen, Jenny ;
Tahirli, Rasim ;
Blakemore, Robert ;
Rustomjee, Roxana ;
Milovic, Ana ;
Jones, Martin ;
O'Brien, Sean M. ;
Persing, David H. ;
Ruesch-Gerdes, Sabine ;
Gotuzzo, Eduardo ;
Rodrigues, Camilla ;
Alland, David ;
Perkins, Mark D. .
NEW ENGLAND JOURNAL OF MEDICINE, 2010, 363 (11) :1005-1015
[4]   A Programmable Bio-Chip With Adaptive Pattern-Control Micro-Electrode-Dot-Array [J].
Chan, Yun-Sheng ;
Lee, Chen-Yi .
IEEE TRANSACTIONS ON CIRCUITS AND SYSTEMS II-EXPRESS BRIEFS, 2022, 69 (11) :4513-4517
[5]   Estimate of Burden and Direct Healthcare Cost of Infectious Waterborne Disease in the United States [J].
Collier, Sarah A. ;
Deng, Li ;
Adam, Elizabeth A. ;
Benedict, Katharine M. ;
Beshearse, Elizabeth M. ;
Blackstock, Anna J. ;
Bruce, Beau B. ;
Derado, Gordana ;
Edens, Chris ;
Fullerton, Kathleen E. ;
Gargano, Julia W. ;
Geissler, Aimee L. ;
Hall, Aron J. ;
Havelaar, Arie H. ;
Hill, Vincent R. ;
Hoekstra, Robert M. ;
Reddy, Sujan C. ;
Scallan, Elaine ;
Stokes, Erin K. ;
Yoder, Jonathan S. ;
Beach, Michael J. .
EMERGING INFECTIOUS DISEASES, 2021, 27 (01) :140-149
[6]   How Much Will It Cost To Monitor Microbial Drinking Water Quality in Sub-Saharan Africa? [J].
Delaire, Caroline ;
Peletz, Rachel ;
Kumpel, Emily ;
Kisiangani, Joyce ;
Bain, Robert ;
Khush, Ranjiv .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2017, 51 (11) :5869-5878
[7]   Understanding the costs of investigating coliform and E.coli detections during routine drinking water quality monitoring [J].
Ellis, Kate ;
Gowdy, Claire ;
Jakomis, Natalie ;
Ryan, Bernadette ;
Thom, Claire ;
Biggs, Catherine A. ;
Speight, Vanessa .
URBAN WATER JOURNAL, 2018, 15 (02) :101-108
[8]   Loop-mediated isothermal amplification assay for rapid detection of common strains of Escherichia coli [J].
Hill, Joshua ;
Beriwal, Shilpa ;
Chandra, Ishwad ;
Paul, Vinod K. ;
Kapil, Aarti ;
Singh, Tripti ;
Wadowsky, Robert M. ;
Singh, Vinita ;
Goyal, Ankur ;
Jahnukainen, Timo ;
Johnson, James R. ;
Tarr, Phillip I. ;
Vats, Abhay .
JOURNAL OF CLINICAL MICROBIOLOGY, 2008, 46 (08) :2800-2804
[9]   APPLICATIONS OF NEXT-GENERATION SEQUENCING Sequencing technologies - the next generation [J].
Metzker, Michael L. .
NATURE REVIEWS GENETICS, 2010, 11 (01) :31-46
[10]   Loop-mediated isothermal amplification of DNA [J].
Notomi, Tsugunori ;
Okayama, Hiroto ;
Masubuchi, Harumi ;
Yonekawa, Toshihiro ;
Watanabe, Keiko ;
Amino, Nobuyuki ;
Hase, Tetsu .
NUCLEIC ACIDS RESEARCH, 2000, 28 (12)