Fatigue and monotonically-loaded reinforced concrete specimens subjected to partial area loading

被引:0
|
作者
Afaghi M. [1 ]
Hrynyk T. [2 ]
Isojeh B. [3 ]
Klausen A.B.E. [1 ]
Øverli J.A. [1 ]
机构
[1] Department of Structural Engineering, Norwegian University of Science and Technology, Trondheim
[2] Department of Civil and Environmental Engineering, University of Waterloo, Waterloo
[3] Department of Civil Engineering, York University, Toronto
关键词
confinement; fatigue; nonlinear finite element analysis; partially loaded area; steel fibre reinforced concrete;
D O I
10.1016/j.engstruct.2024.118311
中图分类号
学科分类号
摘要
The degradation of concrete structures is often due to the continuous application of compressive fatigue loads. Understanding of concrete behaviour in different environmental conditions and under especial fatigue loading arrangements, particularly in cases where the loaded area is smaller than loaded element, herein referred to as partially loaded area, is of utmost importance to make a realistic prediction of the concrete fatigue life for a reliable design of civil engineering infrastructure. This paper focuses on investigating the fatigue performance of reinforced concrete specimens subjected to partially loaded areas, considering the influences of steel fibres, reinforcement arrangement, and the environmental factor of water submergence. A typical example of a partially loaded concrete component subjected to fatigue loading is circular spread footings used as concrete foundations for typical wind turbines. In these types of elements, the compressive strength of the concrete can be enhanced due to the confinement provided by way of lateral restraint stemming from surrounding concrete and reinforcement. However, design codes primarily address static loading and lack specific criteria for fatigue loading in these partially loaded regions. To address this research gap, results from a comprehensive experimental study, which in total included 111 concrete specimens subjected to monotonic loading and 25 specimens tested under cyclic loading, were used to study this problem. The investigation aimed to evaluate the effects of steel fibres and reinforcement arrangement on both static and fatigue capacity. Additionally, the impact of submerging concrete structures in water on their fatigue performance was examined, revealing a decrease in their fatigue life. The experimental results demonstrated that the presence of steel fibres and splitting reinforcement significantly increased both static and fatigue capacity. Most current design codes neglect the environmental factor of water submergence, leading to reduced fatigue capacity in concrete structures. Consequently, the validity of the design codes DNV-OS-C502 and fib Model Code 2010 was evaluated, and a new environmental factor for partially loaded areas subjected to cyclic loading is proposed. To evaluate the experimental results and understand the mechanical response, nonlinear finite element analyses were conducted using a smeared-crack continuum modelling procedure coupled with high cycle fatigue material models to assess its applicability for estimating fatigue performance of partially loaded reinforced concrete elements. It was found that a plane stress modelling procedure was capable of estimating fatigue capacity for dry concrete components, however, overestimated the fatigue capacity of wet concrete components. © 2024 The Authors
引用
收藏
相关论文
共 48 条
  • [21] Structural performance of reinforced concrete beams subjected to combined effects of corrosion and cyclic loading
    Stein K.J.
    Graeff Â.G.
    Garcez M.R.
    Journal of Building Pathology and Rehabilitation, 2023, 8 (1)
  • [22] Behaviour of circular SMA-confined reinforced concrete columns subjected to eccentric loading
    El-Hacha, Raafat
    Abdelrahman, Khaled
    ENGINEERING STRUCTURES, 2020, 215
  • [23] Structural Performance of Steel Reinforced PVA-ECC Beams Subjected to Fatigue Flexural Loading
    Meng, Dan
    Zhang, Y. X.
    Lee, C. K.
    PROCEEDINGS OF THE 25TH AUSTRALASIAN CONFERENCE ON MECHANICS OF STRUCTURES AND MATERIALS (ACMSM25), 2020, 37 : 419 - 426
  • [24] Fatigue behavior of polypropylene fiber reinforced concrete under constant and variable amplitude loading
    Mohamadi, M. R.
    Mohandesi, J. Aghazadeh
    Homayonifar, M.
    JOURNAL OF COMPOSITE MATERIALS, 2013, 47 (26) : 3331 - 3342
  • [25] Experimental and theoretical study of the performance of reinforced concrete specimen subjected to cyclic loading and aggressive environment
    Goeringer, Jakub
    Foglar, Marek
    11TH INTERNATIONAL FATIGUE CONGRESS, PTS 1 AND 2, 2014, 891-892 : 494 - 499
  • [26] IDENTIFICATION OF DAMAGED ZONES IN C/PPS SPECIMENS SUBJECTED TO FATIGUE LOADING BASED ON HIGH-RESOLUTION THERMOGRAPHY
    Koudelka, Petr
    Kytyr, Daniel
    Fenclova, Nela
    Sperl, Martin
    XIVTH YOUTH SYMPOSIUM ON EXPERIMENTAL SOLID MECHANICS, 2016, 3 : 35 - 38
  • [27] Tests of glass fibre reinforced polymer rectangular concrete columns subjected to concentric and eccentric axial loading
    Elchalakani, Mohamed
    Ma, Guowei
    ENGINEERING STRUCTURES, 2017, 151 : 93 - 104
  • [28] Bending performance of high strength steel fibre reinforced concrete - Static and fatigue loading conditions
    Lappa, E. S.
    Braam, C. R.
    Walraven, J. C.
    MEASURING, MONITORING AND MODELING CONCRETE PROPERTIES, 2006, : 133 - +
  • [29] Nonlinear Finite Element Analysis of Reinforced Concrete Flat Slabs Subjected to Reversed-Cyclic Loading
    Setiawan, Andri
    Vollum, Robert
    Macorini, Lorenzo
    HIGH TECH CONCRETE: WHERE TECHNOLOGY AND ENGINEERING MEET, 2018, : 814 - 822
  • [30] Deformation Performance of CFRP-Strengthened Corroded Reinforced Concrete Beams after Fatigue Loading
    Zhang, Zhimei
    Li, Tao
    APPLIED SCIENCES-BASEL, 2023, 13 (10):