DIRECT POWER CONTROL OF DOUBLE-FED INDUCTION GENERATOR BASED ON IMPROVED SUPER-TWISTING

被引:0
|
作者
Li, Shengqing [1 ]
Wen, Yanxi [1 ]
Huang, Yuanpeng [1 ,2 ]
Zhou, Zhifei [1 ]
Chen, Xin [1 ]
机构
[1] School of Electrical and Information Engineering, Hunan University of Technology, Zhuzhou,412007, China
[2] Key Laboratory of Electrical Transmission Control and Intelligent Equipment of Hunan Province, Zhuzhou,412007, China
来源
Taiyangneng Xuebao/Acta Energiae Solaris Sinica | 2024年 / 45卷 / 10期
关键词
Asynchronous generators;
D O I
10.19912/j.0254-0096.tynxb.2023-0941
中图分类号
学科分类号
摘要
A improved Super-twistingl sliding mode(STSMC)direct power control(DPC)is presented to improve the robustness and immunity to interference of the direct power control of a Doubly-fed induction generator(DFIG). Firstly,the Doubly-fed induction generator model with stator field orientation and the DFIG maximum power capture model under parametric regimes are created;Following that,the Non-singular fast terminal sliding mode surface(NFTSM)and an enhanced Super-twisting optimization method are combined to create the DFIG direct power controller(IST-NFTSMC). They include the developed Non-singular sliding mode surface,which can successfully avoid the singularity phenomena of conventional sliding mode control(SMC),and the improved Super-twisting control law,which can successfully reduce the jitter of the NFTSMC and increase the accuracy of the power control;Finally,through simulation and experiment,it is found that compared to the PI control and the conventional sliding mode control,the IST-NFTSMC may reduce the DFIG power and current jitter problem,speed up its convergence,and increase the steady state accuracy of the DFIG direct power management through simulation and experimentation. © 2024 Science Press. All rights reserved.
引用
收藏
页码:529 / 535
相关论文
共 14 条
  • [1] Direct power control strategy of doubly fed induction generator
    Huazhong University of Science and Technology, Wuhan 430074, China
    不详
    Dianli Zidonghua Shebei Electr. Power Autom. Equip., 2006, 4 (31-35):
  • [2] Direct power control for doubly-fed induction generator wind turbines with a constant switching frequency
    Zhejiang University, Hangzhou 310027, China
    Dianli Xitong Zidonghue, 2008, 1 (61-65):
  • [3] Improved super-twisting sliding mode control of a stand-alone DFIG-DC system with harmonic current suppression
    Guo, Lei
    Wang, Dan
    Peng, Zhouhua
    Diao, Liang
    IET POWER ELECTRONICS, 2020, 13 (07) : 1311 - 1320
  • [4] Detection of mixed eccentricity fault in doubly-fed induction generator based on reactive power spectrum
    Faiz, Jawad
    Moosavi, Seyed Mohammad Mahdi
    IET ELECTRIC POWER APPLICATIONS, 2017, 11 (06) : 1076 - 1084
  • [5] Model predictive virtual power control of brushless doubly-fed induction generator for fast and smooth grid synchronisation
    Wei, Xinchi
    Cheng, Ming
    Luo, Rensong
    Xu, Litong
    Zhu, Jianguo
    IET RENEWABLE POWER GENERATION, 2019, 13 (16) : 3080 - 3087
  • [6] Self-tuning fuzzy-PI-based current control algorithm for doubly fed induction generator
    Demirbas, Sevki
    IET RENEWABLE POWER GENERATION, 2017, 11 (13) : 1714 - 1722
  • [7] Bacteria foraging optimisation algorithm based optimal control for doubly-fed induction generator wind energy system
    Bakir, Hale
    Merabet, Adel
    Dhar, Rupak Kanti
    Kulaksiz, Ahmet Afsin
    IET RENEWABLE POWER GENERATION, 2020, 14 (11) : 1850 - 1859
  • [8] Method to estimate sag frequency in doubly fed induction generator integrated power system based on adaptive kernel density estimation
    Wang, Ying
    Tan, Rui
    Zheng, Zi-Xuan
    Ni, Fu-Yao
    Xiao, Xian-Yong
    IET GENERATION TRANSMISSION & DISTRIBUTION, 2020, 14 (07) : 1261 - 1270
  • [9] Numerical-based frequency domain controller design for stand-alone brushless doubly fed induction generator power system
    Sun, Lei
    Chen, Yu
    Peng, Li
    Kang, Yong
    IET POWER ELECTRONICS, 2017, 10 (05) : 588 - 598
  • [10] Improved fault ride through strategy for doubly fed induction generator based wind turbines under both symmetrical and asymmetrical grid faults
    Mohammadi, Jafar
    Afsharnia, Saeed
    Vaez-Zadeh, Sadegh
    Farhangi, Shahrokh
    IET RENEWABLE POWER GENERATION, 2016, 10 (08) : 1114 - 1122