A residual current compensation control method based on a PWM-controlled converter

被引:0
|
作者
Wang P. [1 ]
Feng G. [1 ]
Wang H. [2 ]
Chen M. [2 ]
Zhang J. [2 ]
Shi G. [2 ]
Jia Y. [2 ]
机构
[1] Electric Power Research Institute of State Grid Hehan Electric Power Company, Zhengzhou
[2] Shanghai Jiao Tong University Wind Power Research Center, Shanghai
关键词
Active damping current; Full compensation arc suppression coil; PWM-controlled converter; Residual-current compensation; Single-phase ground fault;
D O I
10.19783/j.cnki.pspc.201357
中图分类号
学科分类号
摘要
There is a problem of poor real-time compensation ability of a grounding residual current of traditional full compensation arc suppression device in a distribution network. There is also a long-time resonance state after fault recovery. Thus a full compensation control method of grounding residual current based on a PWM-controllable converter is proposed. The principle of full compensation fault arc suppression is discussed in detail, and the capacitance to ground is measured by the frequency sweep method. The relationship between zero sequence voltage and residual current component is theoretically deduced, and a real-time control method of residual current full compensation is proposed. The active damping current injection method is used to detect the ground fault recovery in real time, and the calculation basis of active damping current is analyzed theoretically. Finally, a digital simulation study on the compensating effect of the fault current based on a 10 kV single-phase grounding distribution network is carried out. The results show that the grounding fault current can be compensated for quickly and effectively, and the full compensation device can quickly exit the operation after the fault recovery. This shows the correctness and feasibility of the proposed control strategy. © 2021 Power System Protection and Control Press.
引用
收藏
页码:110 / 118
页数:8
相关论文
共 27 条
  • [1] QI Zheng, DIAO Chunyan, CHEN Yanbo, Online identification of the effectiveness of fast fault point transfer arc extinguishing method for distribution networks, Power System Protection and Control, 48, 11, pp. 69-75, (2020)
  • [2] LONG Ruyue, HUANG Chun, TANG Tao, Et al., Line selection method for grounding fault in resonant grounding distribution systems, Power System Protection and Control, 47, 21, pp. 21-29, (2019)
  • [3] YUAN Chao, XUE Yongduan, MEI Rui, Et al., Sensitivity analysis of insulation monitoring of distribution network under different grounding modes, Power System Protection and Control, 48, 3, pp. 130-137, (2020)
  • [4] LIU Weigong, XUE Yongduan, XU Bingyin, Et al., An active arc suppression algorithm adaptable to dynamic structure variation of transmission line, Power System Technology, 38, 7, pp. 2008-2013, (2014)
  • [5] WEI Xiaohui, SHAO Wenquan, CHENG Yuan, Et al., Review of single-phase grounding fault active arc-suppression technologies in distribution network, Electric Power Engineering Technology, 39, 6, pp. 58-65, (2020)
  • [6] KONG Ning, YIN Zhongdong, YANG Po, Et al., Study on automatic tuning arc suppression coil based on PWM-controlled reactor, Power System Protection and Control, 38, 23, pp. 132-136, (2010)
  • [7] AI Shaogui, LI Xiuguang, LI Wei, Et al., Arc suppression technology based on fast switch for distribution network, High Voltage Apparatus, 53, 3, pp. 178-184, (2017)
  • [8] WINTER K M., Swedish distribution networks-a new method for earth fault protection in cable and overhead systems, 1993 Fifth International Conference on Developments in Power System Protection, pp. 268-270, (1993)
  • [9] WANG Wen, ZENG Xiangjun, YAN Lingjie, Et al., Principle and control design of active ground-fault arc suppression device for full compensation of ground current, IEEE Transactions on Industrial Electronics, 64, 6, pp. 4561-4570, (2017)
  • [10] CHEN Baichao, WANG Peng, SHEN Weiwei, Et al., The principle of full compensation arc suppression and flexible control of electromagnetic hybrid petersen coil, Transactions of China Electrotechnical Socitety, 30, 10, pp. 311-318, (2015)