Equilibrium Model With Anisotropy for Model-Based Reconstruction in Magnetic Particle Imaging

被引:0
作者
Maass, Marco [1 ,2 ]
Kluth, Tobias [3 ]
Droigk, Christine [2 ]
Albers, Hannes [3 ]
Scheffler, Konrad [4 ,5 ]
Mertins, Alfred [2 ]
Knopp, Tobias [4 ,5 ,6 ]
机构
[1] German Res Ctr Artificial Intelligence DFKI, D-23562 Lubeck, Germany
[2] Univ Lubeck, Inst Signal Proc, D-23562 Lubeck, Germany
[3] Univ Bremen, Ctr Ind Math, D-28359 Bremen, Germany
[4] Univ Med Ctr Hamburg Eppendorf, Sect Biomed Imaging, D-20246 Hamburg, Germany
[5] Hamburg Univ Technol, Inst Biomed Imaging, D-21073 Hamburg, Germany
[6] Fraunhofer Res Inst Individualized & Cell Based Me, D-23562 Lubeck, Germany
关键词
Mathematical models; Computational modeling; Imaging; Anisotropic magnetoresistance; Magnetization; Image reconstruction; Magnetic moments; Data models; Complexity theory; Particle measurements; Magnetic particle imaging; anisotropic equilibrium model; model-based reconstruction; Lissajous-type excitation; SIMULATION; RESOLUTION; SYSTEM; 2D;
D O I
10.1109/TCI.2024.3490381
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Magnetic particle imaging is a tracer-based tomographic imaging technique that allows the concentration of magnetic nanoparticles to be determined with high spatio-temporal resolution. To reconstruct an image of the tracer concentration, the magnetization dynamics of the particles must be accurately modeled. A popular ensemble model is based on solving the Fokker-Plank equation, taking into account either Brownian or N & eacute;el dynamics. The disadvantage of this model is that it is computationally expensive due to an underlying stiff differential equation. A simplified model is the equilibrium model, which can be evaluated directly but in most relevant cases it suffers from a non-negligible modeling error. In the present work, we investigate an extended version of the equilibrium model that can account for particle anisotropy. We show that this model can be expressed as a series of Bessel functions, which can be truncated based on a predefined accuracy, leading to very short computation times, which are about three orders of magnitude lower than equivalent Fokker-Planck computation times. We investigate the accuracy of the model for 2D Lissajous magnetic particle imaging sequences and show that the difference between the Fokker-Planck and the equilibrium model with anisotropy is sufficiently small so that the latter model can be used for image reconstruction on experimental data with only marginal loss of image quality, even compared to a system matrix-based reconstruction.
引用
收藏
页码:1588 / 1601
页数:14
相关论文
共 50 条
[11]   Mathematical analysis of the 1D model and reconstruction schemes for magnetic particle imaging [J].
Erb, W. ;
Weinmann, A. ;
Ahlborg, M. ;
Brandt, C. ;
Bringout, G. ;
Buzug, T. M. ;
Frikel, J. ;
Kaethner, C. ;
Knopp, T. ;
Maerz, T. ;
Moeddel, M. ;
Storath, M. ;
Weber, A. .
INVERSE PROBLEMS, 2018, 34 (05)
[12]   Model-Based Reconstruction of Large Three-Dimensional Optoacoustic Datasets [J].
Ding, Lu ;
Razansky, Daniel ;
Dean-Ben, Xose Luis .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2020, 39 (09) :2931-2940
[13]   A practical guide for model-based reconstruction in optoacoustic imaging [J].
Dean-Ben, Xose Luis ;
Razansky, Daniel .
FRONTIERS IN PHYSICS, 2022, 10
[14]   Model-based reconstruction for simultaneous multislice and parallel imaging accelerated multishot diffusion tensor imaging [J].
Dong, Zijing ;
Dai, Erpeng ;
Wang, Fuyixue ;
Zhang, Zhe ;
Ma, Xiaodong ;
Yuan, Chun ;
Guo, Hua .
MEDICAL PHYSICS, 2018, 45 (07) :3196-3204
[15]   Sparse-Representation-Based Image Reconstruction for Magnetic Particle Imaging [J].
Sun, Shijie ;
Chen, Yaoyao ;
Janssen, Klaas-Julian ;
Viereck, Thilo ;
Schilling, Meinhard ;
Ludwig, Frank ;
Xu, Lijun ;
Zhong, Jing .
IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2024, 73 :1-9
[16]   Correlation-Based Image Reconstruction Methods for Magnetic Particle Imaging [J].
Ishihara, Yasutoshi ;
Kuwabara, Tsuyoshi ;
Honma, Takumi ;
Nakagawa, Yohei .
IEICE TRANSACTIONS ON INFORMATION AND SYSTEMS, 2012, E95D (03) :872-879
[17]   Model-Based Image Reconstruction for Linear Array Optoacoustic Imaging [J].
Scardigno, Roberto M. ;
Seoni, Silvia ;
Dehner, Christoph ;
Brunetti, Antonio ;
Buongiorno, Domenico ;
Zahnd, Guillaume ;
Meiburger, Kristen M. .
2024 IEEE ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL JOINT SYMPOSIUM, UFFC-JS 2024, 2024,
[18]   A Model-Based Reconstruction Technique for Quantitative Myocardial Perfusion Imaging [J].
Tran-Gia, Johannes ;
Lohr, David ;
Weng, Andreas Max ;
Ritter, Christian Oliver ;
Staeb, Daniel ;
Bley, Thorsten Alexander ;
Koestler, Herbert .
MAGNETIC RESONANCE IN MEDICINE, 2016, 76 (03) :880-887
[19]   Model-based network architecture for image reconstruction in lensless imaging [J].
Zeng, Tianjiao ;
Lam, Edmund Y. .
HOLOGRAPHY, DIFFRACTIVE OPTICS, AND APPLICATIONS X, 2020, 11551
[20]   Adaptive model-based Magnetic Resonance [J].
Beracha, Inbal ;
Seginer, Amir ;
Tal, Assaf .
MAGNETIC RESONANCE IN MEDICINE, 2023, 90 (03) :839-851