Equilibrium Model With Anisotropy for Model-Based Reconstruction in Magnetic Particle Imaging

被引:0
作者
Maass, Marco [1 ,2 ]
Kluth, Tobias [3 ]
Droigk, Christine [2 ]
Albers, Hannes [3 ]
Scheffler, Konrad [4 ,5 ]
Mertins, Alfred [2 ]
Knopp, Tobias [4 ,5 ,6 ]
机构
[1] German Res Ctr Artificial Intelligence DFKI, D-23562 Lubeck, Germany
[2] Univ Lubeck, Inst Signal Proc, D-23562 Lubeck, Germany
[3] Univ Bremen, Ctr Ind Math, D-28359 Bremen, Germany
[4] Univ Med Ctr Hamburg Eppendorf, Sect Biomed Imaging, D-20246 Hamburg, Germany
[5] Hamburg Univ Technol, Inst Biomed Imaging, D-21073 Hamburg, Germany
[6] Fraunhofer Res Inst Individualized & Cell Based Me, D-23562 Lubeck, Germany
关键词
Mathematical models; Computational modeling; Imaging; Anisotropic magnetoresistance; Magnetization; Image reconstruction; Magnetic moments; Data models; Complexity theory; Particle measurements; Magnetic particle imaging; anisotropic equilibrium model; model-based reconstruction; Lissajous-type excitation; SIMULATION; RESOLUTION; SYSTEM; 2D;
D O I
10.1109/TCI.2024.3490381
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Magnetic particle imaging is a tracer-based tomographic imaging technique that allows the concentration of magnetic nanoparticles to be determined with high spatio-temporal resolution. To reconstruct an image of the tracer concentration, the magnetization dynamics of the particles must be accurately modeled. A popular ensemble model is based on solving the Fokker-Plank equation, taking into account either Brownian or N & eacute;el dynamics. The disadvantage of this model is that it is computationally expensive due to an underlying stiff differential equation. A simplified model is the equilibrium model, which can be evaluated directly but in most relevant cases it suffers from a non-negligible modeling error. In the present work, we investigate an extended version of the equilibrium model that can account for particle anisotropy. We show that this model can be expressed as a series of Bessel functions, which can be truncated based on a predefined accuracy, leading to very short computation times, which are about three orders of magnitude lower than equivalent Fokker-Planck computation times. We investigate the accuracy of the model for 2D Lissajous magnetic particle imaging sequences and show that the difference between the Fokker-Planck and the equilibrium model with anisotropy is sufficiently small so that the latter model can be used for image reconstruction on experimental data with only marginal loss of image quality, even compared to a system matrix-based reconstruction.
引用
收藏
页码:1588 / 1601
页数:14
相关论文
共 50 条
  • [11] Model-Based Reconstruction of Large Three-Dimensional Optoacoustic Datasets
    Ding, Lu
    Razansky, Daniel
    Dean-Ben, Xose Luis
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2020, 39 (09) : 2931 - 2940
  • [12] A practical guide for model-based reconstruction in optoacoustic imaging
    Dean-Ben, Xose Luis
    Razansky, Daniel
    FRONTIERS IN PHYSICS, 2022, 10
  • [13] Model-based reconstruction for simultaneous multislice and parallel imaging accelerated multishot diffusion tensor imaging
    Dong, Zijing
    Dai, Erpeng
    Wang, Fuyixue
    Zhang, Zhe
    Ma, Xiaodong
    Yuan, Chun
    Guo, Hua
    MEDICAL PHYSICS, 2018, 45 (07) : 3196 - 3204
  • [14] Sparse-Representation-Based Image Reconstruction for Magnetic Particle Imaging
    Sun, Shijie
    Chen, Yaoyao
    Janssen, Klaas-Julian
    Viereck, Thilo
    Schilling, Meinhard
    Ludwig, Frank
    Xu, Lijun
    Zhong, Jing
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2024, 73 : 1 - 9
  • [15] Correlation-Based Image Reconstruction Methods for Magnetic Particle Imaging
    Ishihara, Yasutoshi
    Kuwabara, Tsuyoshi
    Honma, Takumi
    Nakagawa, Yohei
    IEICE TRANSACTIONS ON INFORMATION AND SYSTEMS, 2012, E95D (03) : 872 - 879
  • [16] Model-Based Image Reconstruction for Linear Array Optoacoustic Imaging
    Scardigno, Roberto M.
    Seoni, Silvia
    Dehner, Christoph
    Brunetti, Antonio
    Buongiorno, Domenico
    Zahnd, Guillaume
    Meiburger, Kristen M.
    2024 IEEE ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL JOINT SYMPOSIUM, UFFC-JS 2024, 2024,
  • [17] A Model-Based Reconstruction Technique for Quantitative Myocardial Perfusion Imaging
    Tran-Gia, Johannes
    Lohr, David
    Weng, Andreas Max
    Ritter, Christian Oliver
    Staeb, Daniel
    Bley, Thorsten Alexander
    Koestler, Herbert
    MAGNETIC RESONANCE IN MEDICINE, 2016, 76 (03) : 880 - 887
  • [18] Adaptive model-based Magnetic Resonance
    Beracha, Inbal
    Seginer, Amir
    Tal, Assaf
    MAGNETIC RESONANCE IN MEDICINE, 2023, 90 (03) : 839 - 851
  • [19] Model-based network architecture for image reconstruction in lensless imaging
    Zeng, Tianjiao
    Lam, Edmund Y.
    HOLOGRAPHY, DIFFRACTIVE OPTICS, AND APPLICATIONS X, 2020, 11551
  • [20] Dual-Feature Frequency Component Compression Method for Accelerating Reconstruction in Magnetic Particle Imaging
    Zhang, Peng
    Liu, Jie
    Li, Yimeng
    Yin, Lin
    An, Yu
    Zhong, Jing
    Hui, Hui
    Tian, Jie
    IEEE TRANSACTIONS ON COMPUTATIONAL IMAGING, 2023, 9 : 289 - 297