A Joint Active Damping Strategy Based on LCL-Type Grid-Connected Inverters for Grid Current Feedback and PCC Voltage Unit Feedforward

被引:0
|
作者
Ke, Shanwen [1 ]
Liang, Bo [1 ]
机构
[1] Northwestern Polytech Univ, Sch Automat, Xian 710072, Peoples R China
关键词
active damping; grid current feedback (GCF); joint active damping; robustness; grid impedance; CAPACITOR CURRENT-FEEDBACK; CURRENT CONTROLLER; STABILITY ANALYSIS; ROBUST DESIGN; CONVERTERS; FILTERS;
D O I
10.3390/s24186029
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The negative high-pass filter feedback of the grid current (NFGCF) can offer active damping for the LCL-type grid-connected inverter. Due to the control delay in digital control systems, this damping can cause the system to exhibit non-minimum phase behavior within specific frequency ranges. This study proposes a joint active damping approach that combines grid current feedback and the point of common coupling (PCC) voltage unit feedforward. The proposed method introduces a dynamic damping region that varies with grid impedance. By developing suitable damping loop control parameters, this region can span the entire frequency range, even exceeding the Nyquist frequency f(s)/2. The research results demonstrate that the proposed approach enhances robustness against variations in grid impedance and eliminates non-minimum phase behavior. Simulation and experimental outcomes validate the effectiveness of this joint active damping method.
引用
收藏
页数:18
相关论文
共 50 条
  • [31] Passivity-Oriented Design of LCL-Type Grid-Connected Inverters With Luenberger Observer-Based Active Damping
    Zhao, Jiancheng
    Xie, Chuan
    Li, Kai
    Zou, Jianxiao
    Guerrero, Josep M.
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2022, 37 (03) : 2625 - 2635
  • [32] NEW TYPE CAPACITTIVE VOLTAGE ACTIVE DAMPING STRATEGY FOR LCL GRID-CONNECTED INVERTER
    Yang M.
    Song M.
    Zhang G.
    Xie B.
    Taiyangneng Xuebao/Acta Energiae Solaris Sinica, 2023, 44 (02): : 399 - 408
  • [33] Design of grid-connected inverters with LCL filter based on PI regulator and capacitor current feedback active damping
    Bao, C. (baochenlei@smail.hust.edu.cn), 1600, Chinese Society for Electrical Engineering (32):
  • [34] Grid-Current-Feedback Active Damping for LCL Resonance in Grid-Connected Voltage-Source Converters
    Wang, Xiongfei
    Blaabjerg, Frede
    Loh, Poh Chiang
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2016, 31 (01) : 213 - 223
  • [35] Synthesis of Active Damping for Grid-Connected Inverters with an LCL filter
    Xiao, Huafeng
    Qu, Xiaohui
    Xie, Shaojun
    Xu, Jinming
    2012 IEEE ENERGY CONVERSION CONGRESS AND EXPOSITION (ECCE), 2012, : 550 - 556
  • [36] Robust current control strategy for LCL-type grid-connected converter based on additional unit time-delay feedback
    Wang Q.
    Qin W.
    Zhang Y.
    Dai W.
    Han X.
    Xu Z.
    Dong R.
    Dianli Zidonghua Shebei/Electric Power Automation Equipment, 2020, 40 (09): : 203 - 210
  • [37] Analysis and Design of Improved Weighted Average Current Control Strategy for LCL-Type Grid-Connected Inverters
    Han, Yang
    Li, Zipeng
    Yang, Ping
    Wang, Congling
    Xu, Lin
    Guerrero, Josep M.
    IEEE TRANSACTIONS ON ENERGY CONVERSION, 2017, 32 (03) : 941 - 952
  • [38] Full-State Feedback Based Active Damping Control Design for LCL-type Grid-Connected Converter under Weak Grid
    Guo, Zhengchen
    Zou, Xudong
    Huang, Yanrun
    Kang, Yong
    Zou, Kaifeng
    2018 IEEE INTERNATIONAL POWER ELECTRONICS AND APPLICATION CONFERENCE AND EXPOSITION (PEAC), 2018, : 1360 - 1365
  • [39] Single current feedback control strategy for grid-connected inverters with LCL filters
    Chen, Dong
    Zhang, Junming
    Qian, Zhaoming
    Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2013, 33 (09): : 10 - 16
  • [40] Inner-Outer Loop based Robust Active Damping for LCL Resonance in Grid-Connected Inverters using Grid Current Feedback
    Sarkar, Aratrik
    Puttannaiah, Karan
    Rodriguez, Armando A.