Optimizing charge transport simulation for hybrid pixel detectors

被引:0
|
作者
Xie, X. [1 ]
Barten, R. [1 ]
Bergamaschi, A. [1 ]
Braham, B. [1 ]
Bruckner, M. [1 ]
Carulla, M. [1 ]
Dinapoli, R. [1 ]
Ebner, S. [1 ]
Ferjaoui, K. [1 ]
Greiffenberg, D. [1 ]
Hasanaj, S. [1 ]
Heymes, J. [1 ]
Hinger, V. [1 ]
King, T. [1 ]
Kozlowski, P. [1 ]
Lopez-Cuenca, C. [1 ]
Mezza, D. [1 ]
Moustakas, K. [1 ]
Mozzanica, A. [1 ]
Paton, K. A. [1 ]
Ruder, C. [1 ]
Schmitt, B. [1 ]
Sieberer, P. [1 ]
Thattil, D. [1 ]
Zhang, J. [1 ]
Frojdh, E. [1 ]
机构
[1] Paul Scherrer Inst, Ctr Photon Sci, Forschungsstr 111, CH-5232 Villigen, Switzerland
来源
JOURNAL OF INSTRUMENTATION | 2024年 / 19卷 / 10期
关键词
Charge transport and multiplication in solid media; Detector modelling and simulations II (electric fields; charge transport; multiplication and induction; pulse formation; electron emission; etc); ELECTRON; SILICON; PENETRATION;
D O I
10.1088/1748-0221/19/10/C10007
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
To enhance the spatial resolution of the M & Ouml;NCH 25 mu m pitch hybrid pixel detector, deep learning models have been trained using both simulation and measurement data. Challenges arise when comparing simulation-based deep learning models to measurement-based models for electrons, as the spatial resolution achieved through simulations is notably inferior to that from measurements. Discrepancies are also observed when directly comparing X-ray simulations with measurements, particularly in the spectral output of single pixels. These observations collectively suggest that current simulations require optimization. To address this, the dynamics of charge carriers within the silicon sensor have been studied using Monte Carlo simulations, aiming to refine the charge transport modeling. The simulation encompasses the initial generation of the charge cloud, charge cloud drift, charge diffusion and repulsion, and electronic noise. The simulation results were validated with measurements from the M & Ouml;NCH detector for X-rays, and the agreement between measurements and simulations was significantly improved by accounting for the charge repulsion.
引用
收藏
页数:11
相关论文
共 50 条
  • [41] Study of the signal response of the MONCH 25μm pitch hybrid pixel detector at different photon absorption depths
    Cartier, S.
    Bergamaschi, A.
    Dinapoli, R.
    Greiffenberg, D.
    Johnson, I.
    Jungmann-Smith, J. H.
    Mezza, D.
    Mozzanica, A.
    Shi, X.
    Tinti, G.
    Schmitt, B.
    Stampanoni, M.
    JOURNAL OF INSTRUMENTATION, 2015, 10
  • [42] TCAD simulation of the electrical properties of a novel meander strip electrode pixel High-Purity Germanium detector
    Wang, Mingyang
    Liu, Manwen
    Zhao, Jun
    Long, Tao
    Xiong, Bo
    Li, Zheng
    Xiao, Yongguang
    JOURNAL OF INSTRUMENTATION, 2025, 20 (03):
  • [43] Electric field distribution in Si detectors irradiated with 40Ar ions: experimental study and simulation
    Verbitskaya, E.
    Eremin, V
    Shepelev, A.
    JOURNAL OF INSTRUMENTATION, 2020, 15 (02)
  • [44] Geant4-based simulations of charge collection in CMOS Active Pixel Sensors
    Esposito, M.
    Price, T.
    Anaxagoras, T.
    Allinson, N. M.
    JOURNAL OF INSTRUMENTATION, 2017, 12
  • [45] Theoretical analysis of the effect of charge-sharing on the Detective Quantum Efficiency of single-photon counting segmented silicon detectors
    Marchal, J.
    JOURNAL OF INSTRUMENTATION, 2010, 5
  • [46] GPU-accelerated CZT detector simulation with charge build-up effects
    Delcourt, A.
    Montemont, G.
    JOURNAL OF INSTRUMENTATION, 2023, 18 (02)
  • [47] Study of charge carrier transport properties and lifetimes in HR GaAs:Cr with Timepix3
    Smolyanskiy, P.
    Bergmann, B.
    Billoud, T.
    Burian, P.
    Sitarz, M.
    Sondergaard, C.
    Pospisil, S.
    JOURNAL OF INSTRUMENTATION, 2021, 16 (12):
  • [48] Validation and performance comparison of different types of combined scintillation detectors for animal PET imaging system using GATE simulation
    Sadremomtaz, A.
    Ghalebin, M. Mohammadi
    JOURNAL OF INSTRUMENTATION, 2022, 17 (05)
  • [49] Spectroscopic analysis of charge transport characteristics in wide-band-gap semiconductor detectors
    Kim, YS
    Cho, GS
    Kim, HK
    Kim, KH
    Kim, HJ
    MEDICAL IMAGING 2002: PHYSICS OF MEDICAL IMAGING, 2002, 4682 : 601 - 611
  • [50] Simulation of electron transport in a catoptric photomultiplier tube concept for large rectangular scintillator crystals
    Beavers, J.
    Huddleston, K.
    Hines, N.
    McNeil, W.
    JOURNAL OF INSTRUMENTATION, 2024, 19 (04)