Comparison and regional suitability evaluation of different backfill source heat pumps using TRNSYS

被引:0
作者
Zhao, Yujiao [1 ,2 ]
Wang, Mengyao [3 ]
Liu, Lang [1 ,2 ]
Zhang, Bo [1 ,2 ]
Li, Yan [4 ]
Wang, Mei [1 ,2 ]
Zhang, Hailong [1 ,2 ]
机构
[1] Xian Univ Sci & Technol, Coll Energy Engn, Xian 710054, Peoples R China
[2] Minist Educ China, Key Lab Western Mines & Hazards Prevent, Xian, Peoples R China
[3] Xian Univ Sci & Technol, Coll Architecture & Civil Engn, Xian 710054, Peoples R China
[4] Xian Univ Finance & Econ, Sch Business, Xian 710100, Peoples R China
关键词
Solar energy; Seasonal heat storage; TRNSYS; Backfill; Regional suitability evaluation; PERFORMANCE ANALYSIS; SYSTEM; SIMULATION; COLLECTOR; LOAD;
D O I
10.1016/j.enbuild.2024.114826
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
As global energy demand and carbon emissions continues to rise year by year, the use of renewable energy for heating becomes increasingly urgent. This study employs solar and geothermal energy to supply heat to mining facilities. Initially, three distinct heating systems for mining areas were modeled in TRNSYS: the Backfill Source Heat Pump (BSHP), the Solar Assisted Backfill Source Heat Pump (SABSHP), and the Solar Assisted Backfill Source Heat Pump with Seasonal Heat Storage (SABSHP-SHS). Following a decade of simulation, the optimal system was identified through a comparative analysis that encompassed backfill temperature equilibrium, the inlet and outlet water temperatures for buried pipes, Coefficient of Performance (COP), Partial Load Ratio (PLR), and economic factors. Over the 10-year simulation period, the COP and PLR of the SABSHP-SHS system outperformed both the BSHP and SABSHP systems, showing higher energy efficiency and better heat pump performance. To further assess the regional adaptability of the SABSHP-SHS system, simulations were conducted across four regions with diverse climatic profiles: Shijiazhuang, Yan'an, Xining, and Hegang. The analysis focused on heat collection, efficiency, backfill temperature variation, system energy consumption, and the energy efficiency ratio. The findings indicate that Hegang exhibits the highest solar heat collection efficiency at 89.9% during the non-heating season, while Xining achieves a significantly higher heat collection efficiency of 54.1% during the heating season. These results suggest that the SABSHP-SHS system is particularly effective in regions with pronounced seasonal variations, characterized by extended cold winters and brief, intense summers.
引用
收藏
页数:15
相关论文
共 50 条
  • [41] Comparison of energy performance of heat pumps using a photovoltaic-thermal evaporator with circular and triangular tube configurations
    Mohanraj, M.
    Gunasekar, N.
    Velmurugan, V.
    BUILDING SIMULATION, 2016, 9 (01) : 27 - 41
  • [42] Energy consumption of cold climate heat pumps in different climates - Comparison of single-stage and two-stage systems
    Gschwend, Andreas
    Menzi, Tobias
    Caskey, Stephen
    Groll, Eckhard A.
    Bertsch, Stefan S.
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2016, 62 : 193 - 206
  • [43] Numerical ragweed pollen forecasts using different source maps: a comparison for France
    Zink, Katrin
    Kaufmann, Pirmin
    Petitpierre, Blaise
    Broennimann, Olivier
    Guisan, Antoine
    Gentilini, Eros
    Rotach, Mathias W.
    INTERNATIONAL JOURNAL OF BIOMETEOROLOGY, 2017, 61 (01) : 23 - 33
  • [44] Yearly photoelectric/thermal and economic performance comparison between CPV and FPV dual-source heat pump systems in different regions
    Song, Zhiying
    Zhang, Yuzhe
    Ji, Jie
    He, Wei
    Hu, Zhongting
    Xuan, Qingdong
    ENERGY, 2024, 289
  • [45] Suitability zoning of buried pipe ground source heat pump and shallow geothermal resource evaluation of Linqu County, Shandong Province, China
    Hu, Ziyuan
    Gao, Zongjun
    Xu, Xiqiang
    Fang, Shaoyan
    Zhou, Liangyu
    Ji, Deshuai
    Li, Fuquan
    Feng, Jianguo
    Wang, Min
    RENEWABLE ENERGY, 2022, 198 : 1430 - 1439
  • [46] Energy performance prediction of vapor-injection air source heat pumps in residential buildings using a neural network model
    Wang, Zhichao
    Liu, Xiaoyu
    Shen, Hui
    Wang, Yichao
    Li, Haorong
    ENERGY AND BUILDINGS, 2020, 228
  • [47] Multi-objective spectral range optimization for different heat source temperatures to maximize thermophotovoltaic performance using NSGA-II
    Liu, Xiu-Li
    Li, Xiao-Lei
    Xia, Xin-Lin
    Chen, Xue
    RENEWABLE ENERGY, 2024, 237
  • [48] Exergoeconomic comparison of TLC (trilateral Rankine cycle), ORC (organic Rankine cycle) and Kalina cycle using a low grade heat source
    Yari, M.
    Mehr, A. S.
    Zare, V.
    Mahmoudi, S. M. S.
    Rosen, M. A.
    ENERGY, 2015, 83 : 712 - 722
  • [49] A study on the energy performance of a ground source heat pump utilized in the refurbishment of an historical building: comparison of different design options
    Pacchiega, Claudia
    Fausti, Patrizio
    CLIMAMED 2017 - MEDITERRANEAN CONFERENCE OF HVAC HISTORICAL BUILDINGS RETROFIT IN THE MEDITERRANEAN AREA, 2017, 133 : 349 - 357
  • [50] Risk and reliability assessment of solar-assisted air source heat pumps using fuzzy logic-based failure modes and effects analysis
    Sun, Tianmei
    Chong, Wen Tong
    Khairuddin, Anis Salwa Mohd
    Tey, Kok Soon
    Wang, Xinru
    Wu, Jinshun
    Pan, Song
    JOURNAL OF BUILDING ENGINEERING, 2025, 103