摘要
As global energy demand and carbon emissions continues to rise year by year, the use of renewable energy for heating becomes increasingly urgent. This study employs solar and geothermal energy to supply heat to mining facilities. Initially, three distinct heating systems for mining areas were modeled in TRNSYS: the Backfill Source Heat Pump (BSHP), the Solar Assisted Backfill Source Heat Pump (SABSHP), and the Solar Assisted Backfill Source Heat Pump with Seasonal Heat Storage (SABSHP-SHS). Following a decade of simulation, the optimal system was identified through a comparative analysis that encompassed backfill temperature equilibrium, the inlet and outlet water temperatures for buried pipes, Coefficient of Performance (COP), Partial Load Ratio (PLR), and economic factors. Over the 10-year simulation period, the COP and PLR of the SABSHP-SHS system outperformed both the BSHP and SABSHP systems, showing higher energy efficiency and better heat pump performance. To further assess the regional adaptability of the SABSHP-SHS system, simulations were conducted across four regions with diverse climatic profiles: Shijiazhuang, Yan'an, Xining, and Hegang. The analysis focused on heat collection, efficiency, backfill temperature variation, system energy consumption, and the energy efficiency ratio. The findings indicate that Hegang exhibits the highest solar heat collection efficiency at 89.9% during the non-heating season, while Xining achieves a significantly higher heat collection efficiency of 54.1% during the heating season. These results suggest that the SABSHP-SHS system is particularly effective in regions with pronounced seasonal variations, characterized by extended cold winters and brief, intense summers.
引用
收藏
页数:15
相关论文
共 50 条
  • [31] Performance evaluation of ground source heat pump using linear and nonlinear regressions and artificial neural networks
    Xu, Xinjie
    Liu, Jinxiang
    Wang, Yu
    Xu, Jinjun
    Bao, Jun
    APPLIED THERMAL ENGINEERING, 2020, 180
  • [32] COMPARISON OF THE ENERGY CONSUMPTION OF GROUND-SOURCE AND AIR-TO-WATER PROPANE HEAT PUMPS FOR THE HEATING NEEDS AROUND EUROPE
    Tammaro, M.
    Montagud, C.
    Corberan, J. M.
    Mauro, A. W.
    Mastrullo, R.
    12TH IIR GUSTAV LORENTZEN NATURAL WORKING FLUIDS CONFERENCE, 2016, : 837 - 844
  • [33] A Techno-Economic Comparison between PV and PVT Integrated Ground Source Heat Pumps for Multi-Family Houses
    Sommerfeldt, Nelson
    Madani, Hatef
    PROCEEDINGS OF THE ISES EUROSUN 2018 CONFERENCE - 12TH INTERNATIONAL CONFERENCE ON SOLAR ENERGY FOR BUILDINGS AND INDUSTRY, 2018, : 901 - 910
  • [34] Suitability and feasibility study on the application of groundwater source heat pump (GWSHP) system in residential buildings for different climate zones in China
    Liu, Zhijian
    Zhang, Yulong
    Xu, Wei
    Yang, Xinyan
    Liu, Yuanwei
    Jin, Guangya
    ENERGY REPORTS, 2020, 6 : 2587 - 2603
  • [35] Improving reverse cycle defrosting performance of air source heat pumps using thermal storage-based refrigerant sub-cooling energy
    Dong Jiankai
    Jiang Yiqiang
    Deng Shiming
    Yao Yang
    Qu Minglu
    BUILDING SERVICES ENGINEERING RESEARCH & TECHNOLOGY, 2012, 33 (02) : 223 - 236
  • [36] Energy piles for ground source heat pump applications: Comparison of heat transfer performance for different design and operating parameters
    Carotenuto, Alberto
    Marotta, Pasquale
    Massarotti, Nicola
    Mauro, Alessandro
    Normino, Gennaro
    APPLIED THERMAL ENGINEERING, 2017, 124 : 1492 - 1504
  • [37] Enhancing Heating Performance of Low-Temperature Air Source Heat Pumps Using Compressor Casing Thermal Storage
    Liu, Zhongbao
    Lou, Fengfei
    Qi, Xin
    Shen, Yiyao
    ENERGIES, 2020, 13 (12)
  • [38] Effectiveness of using spiral ground heat exchangers in ground source heat pump system of a building for district heating/cooling purposes: Comparison among different configurations
    Dehghan, Babak B.
    APPLIED THERMAL ENGINEERING, 2018, 130 : 1489 - 1506
  • [39] Comparison study of thermoclinic heat storage tanks using different liquid metals for concentrated solar power
    Wang, Gang
    Xie, Zheng
    Peng, Haichao
    Jiang, Tieliu
    CASE STUDIES IN THERMAL ENGINEERING, 2023, 41
  • [40] Thermodynamic analysis of single-stage compression air-source heat pumps with different recuperation ways for large temperature lift
    Sun, Shoujun
    Guo, Hao
    Gong, Maoqiong
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2019, 108 : 91 - 102