Study on axial compression performance of palm-tenon spliced timber columns reinforced with BFRP sheets

被引:0
|
作者
Xu J. [1 ]
Jiang S. [1 ]
Ge Z. [1 ]
Lin E. [2 ]
Lin J. [3 ]
Fu C. [4 ]
机构
[1] College of Civil Engineering, Fuzhou University, Fuzhou
[2] Rongsheng Construction and Development Co., Ltd, Fuzhou
[3] Fujian Wuzhou Construction Group Co., Ltd, Quanzhou
[4] Fujian Academy of Building Research Co., Ltd, Fuzhou
关键词
axial bearing capacity; axial compression test; BFRP sheet; ductility; finite element analysis; palm-tenon splice joint;
D O I
10.14006/j.jzjgxb.2022.0347
中图分类号
学科分类号
摘要
In order to study the axial compression performance of palm-tenon spliced timber columns reinforced with BFRP sheets (referred to as the reinforced timber column), the axial compression test was carried out on 10 specimens, including seven splicing columns with different number of BFRP transverse and longitudinal fiber layers, one ke-ban splicing column and two intact timber columns. The failure characteristics and load-displacement curves of the columns were analyzed, and a comparison was made between the before- and after-reinforcement columns for the failure mode, strain state, bearing capacity, stiffness and ductility. In order to accurately calculate the displacement ductility coefficient of timber components, the ESEP method was proposed to determine the nominal yield point of timber column. The results show that the integrity of the splicing area is good for the specimens with composite reinforcement of BFRP, and the ultimate bearing capacity and stiffness of reinforced timber columns can be restored to 80% -90% level of intact timber columns, as well as ductility can be increased by 9% -90% . This indicates that the reinforced timber columns have good mechanical performance. The nominal yield displacement determined by ESEP method is reasonable and reliable, which can be used to determine the yield point of timber components. Furthermore, a numerical simulation model was established, and the validity of the model was verified by the experimental results. Based on the model, the effect of splice height (hd) and splice length (ld) on the reinforced timber column were analyzed. A calculation formula was derived for the axial compression capacity of the reinforced timber column. The finite element analysis shows that the bearing capacity decreases with the increase of hd, and ld has little effect on the bearing capacity. The maximum error between the calculated value and the test value is 12. 1% . The formula proposed in this paper can provide reference for the retrofitting of timber structures. © 2024 Science Press. All rights reserved.
引用
收藏
页码:197 / 207
页数:10
相关论文
共 22 条
  • [1] Technical standards for maintenance and strengthening of historic timber building: GB / T 50165—2020 [ S ], (2020)
  • [2] YANG Jian, Research on mechanical performance of reinforced wooden columns in Huipai ancient architecture, pp. 40-72, (2021)
  • [3] ZHOU Qian, YANG Na, YAN Weiming, Et al., Axial compression experiments on reinforced bottom rotten wood column by traditional iron hoop pier joint method [ J], Sciences of Conservation and Archaeology, 29, 5, pp. 33-40, (2017)
  • [4] LIU Chengwei, Research on reinforcement technologies of wooden structure in villages and small towns, pp. 36-71, (2011)
  • [5] LI Hongmin, Study on suitable strengthening for ancient timber buildings, pp. 14-53, (2018)
  • [6] SHEN D J, LI M, KANG J C, Et al., Experimental studies on the seismic behavior of reinforced concrete beam-column joints strengthened with basalt fiber-reinforced polymer sheets, Construction and Building Materials, 287, (2021)
  • [7] ZHANG Jinghang, XIA Zhanghua, JIANG Shaofei, Et al., Experimental study on seismic behavior of concrete pier columns strengthened with BFRP mould shell, Journal of Building Structures, 42, 8, pp. 84-94, (2021)
  • [8] ZHOU W J, LI H T, MOHRMANN S, Et al., Evaluation on the axial compression mechanical properties of short BFRP laminated bamboo lumber columns, Journal of Building Engineering, 53, (2022)
  • [9] ZHOU L H, LIU Q, MA S, Et al., Eccentric compression behavior of long poplar columns externally reinforced by BFRP [ J], Journal of Wood Science, 67, 1, pp. 1-17, (2021)
  • [10] PAN Yi, AN Renbing, ZHANG Chuntao, Et al., Experimental study on flexural behavior of BFRP reinforced circular timber beams, Journal of Building Structures, 40, 10, pp. 197-206, (2019)